6.19 Service Messages
Service channels are available for the surveillance of the operation of the Smart Weather
Sensor.
Request Channels:
UMB Channel
Measuring Range
act
min
max
avg
Measurement Variable (float32)
min
max
unit
10000
Supply Voltage V
0.0
50.0
V
11000
Rain Drop Volume µ
0.0
500.0
µl
WS100-UMB only: Air temperature (without radiation shield)
Sampling rate 1 minute
Generation of average value 1 10 minutes
Units °C; °F
Request channels:
UMB Channel
Measuring Range
act
min
max
avg
Measurement Variable (float32)
min
max
unit
4100
4120
4140
4160
Air temperature
-50.0
60.0
°C
4105
4125
4145
4165
Air temperature
-58.0
140.0
°F
6.20 Drop Diameter Distribution (WS100 only)
Drop diameters of precipitation detected by the radar sensor are shown as distribution of
drop diameter classes. Diameters are calculated as volume equivalent ball diameter.
Sampling Rate Event dependent
Unit Number of events
Abfragekanäle:
UMB Channel
Measurement Variable (uint32)
Unit
4600
Total precipitation particles
Events
4601
Total drops
Events
UMB Channel
Measurement Variable (uint16)
Unit
4602
Drizzle particles
Events
4603
Snow particles
Events
4604
Hail particles
Events
4620
Cl. 0: Drops < 0.5mm equiv. diameter
Events
4621
Cl 1: Drops 0.5 .. 1.0mm equiv. diameter
Events
4622
Cl 2: Drops 1.0 .. 1.5mm equiv. diameter
Events
4623
Cl 3: Drops 1.5 .. 2.0mm equiv. diameter
Events
4624
Cl 4: Drops 2.0 .. 2.5mm equiv. diameter
Events
4625
Cl 5: Drops 2.5 .. 3.0mm equiv. diameter
Events
4626
Cl 6: Drops 3.0 .. 3.5mm equiv. diameter
Events
4627
Cl 7: Drops 3.5 .. 4.0mm equiv. diameter
Events
4628
Cl 8: Drops 4.0 .. 4.5mm equiv. diameter
Events
4629
Cl 9: Drops 4.5 .. 5.0mm equiv. diameter
Events
4630
Cl 10: Drops 5.0 .. 5.5mm equiv. diameter
Events
4631
Cl 11: Drops > 5.5mm equiv. diameter
Events
Note: Similar to the request of differential precipitation quantity the accumulated sum of
events of each channel will be reset to 0 after transmission!
For consistent results all related channels should be requested in one run.
If the response from the device is lost due to a transmission error (e.g. poor GPRS
connection), the quantity accumulated to date is also lost. The quantity accumulated to date
is also reset each time the equipment is rebooted.