Users Manual

Operating Manual Smart Weather Sensor
24 G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
6.16 Heating Temperature
Sampling Rate 1 Minute
Units °C; °F
Request Channels:
UMB Channel
Measuring Range
act
min
max
avg
Measurement Variable (float32)
min
max
Unit
112
Heating Temperature Wind Sensor
-50.0
150.0
°C
113
Heating Temperature Precipitation Sensor
-50.0
150.0
°C
117
Heating Temperature Wind Sensor
-58.0
302.0
°F
118
Heating Temperature Precipitation Sensor
-58.0
302.0
°F
6.17 Global Radiation
Sampling Rate 10 seconds
Generation of average values 1 10 minutes *)
Unit W/m²
Request Channels:
UMB Channel
Measuring Range
act
min
max
avg
Measurement Variable (float32)
min
max
unit
900
920
940
960
Global Radiation
0.0
2000.0 *)
W/m²
*) Until device version .49 / .212 / Firmware v5.6: 1400.0 W/m
2
*) Note: The average, maximum and minimum values are evaluated from the 1 minute
averages of the 10 second spot value.
When operated in Power Saving Mode 1 (see page 45) the WS700-UMB will measure the
global radiation only once per minute.
6.18 Lightning Sensor
6.18.1 Lightning Events
Sampling Rate 1 minute
Sum 1 30 minutes
Unit Events
Request Channels:
UMB Channel
Measuring Range
act
sum
Measurement Variable (uint16)
min
max
unit
617
Lightning Events
0
255
-
677
Lightning Events (Interval)
0
7650
-