Users Manual
Operating Manual Smart Weather Sensor
132 G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany
19.6.15 Message: Setting the Heating Mode
The heating of the precipitation and the wind sensors can be configured in different operation
modes (see chapter 10.4). Depending on the actual variant of the Smart Weather Sensor
(WS100-UMB ...WS800-UMB) only certain combinations of operating modes are available.
The Smart Weather Sensor evaluates the valid combinations from the device heating mode
requested in the command automatically.
Command: aXMn!
n: Heating Operating Mode (0: Automatic, 1: Mode 1, 2: Off, 3: Eco Mode 1)
Response: aXMnm<CR><LF>
n: Selected Heating Mode Wind Sensor
m: Selected Heating Mode Precipitation Sensor
The response to the attempt of setting an invalid operation mode is
aXMf<CR><LF>
Example: A WS400-UMB shall be set to Mode 1
0XM1!
0XM21<CR><LF>
As the WS400-UMB does not have a wind sensor the heating mode wind is automatically set
to 2 (= off).
0XD+633.0<CR><LF>