Operating Manual
IRS31Pro-UMB Operating Manual V10 / 01.2020
G. Lufft Mess- und Regeltechnik GmbH 60
18.5.11 Message: Setting of the Threshold for Critical Road Conditions
The command sets the threshold of road surface temperature, below which critical road conditions are
set.
Command: aXT<+/->nn.n!
nn.n: road surface temperature threshold in °C
Response: aXT<+/->nn.n<CR><LF>
The response to the attempt of setting of an invalid value is
aXTf<CR><LF>
Example: The threshold is set to -0.5°C
0XT-0.5!
0XT-0.5<CR><LF>
18.5.12 Message: Station Reset
The command initiates a station reset.
Command: aXR!
Response: aXRok<CR><LF>
The response is followed by the station reset, i.e. the station will be offline for a few seconds.
Example:
0XR!