18.5.7 Message Change of Unit System
The command is used to change the unit system used for the SDI12 data between metric and US units. It
is implemented as manufacturer specific X command.
Command: aXU<u/m>!
Response: aXU<u/m><CR><LF>
u : US units
m: metric units
Example: change to metric units, SDI-12 address ‘0’
0XUm!
0XUm<CR><LF>
18.5.8 Message Selection of Spot or Average Value
The command is used to select average or spot value for transmission. It is implemented as manufacturer
specific X command.
Command: aXA<a/c>!
Response: aXA<a/c><CR><LF>
a : average
c: spot
Example: change to average values
0XAa!
0XAa<CR><LF>
18.5.9 Message: Setting of the Threshold for Road Condition “Moist”
The command sets the threshold of water film height, above which the road condition is set to “moist”.
Command: aXM+nnn!
nnn: water film height threshold in µm
Response: aXM+nnn<CR><LF>
The response to the attempt of setting of an invalid value is
aXMf<CR><LF>
Example: The threshold is set to 20 µm
0XM+20!
0XM+20<CR><LF>
18.5.10 Message: Setting of the Threshold for Road Condition “Wet”
The command sets the threshold of water film height, above which the road condition is set to “wet”.
Command: aXW+nnn!
nnn: water film height threshold in µm
Response: aXW+nnn<CR><LF>
The response to the attempt of setting of an invalid value is
aXWf<CR><LF>
Example: The threshold is set to 220 µm
0XW+220!
0XW+220<CR><LF>