Operating Manual
IRS31Pro-UMB Operating Manual V10 / 01.2020
G. Lufft Mess- und Regeltechnik GmbH 12
Units: none
Request channels:
UMB Channel Measuring Range
act min max avg Measured Value Data Type min max Unit
820 825 Friction float32 0.0 1.0
6.1.12 Saline Concentration MgCl
2
2
Sampling rate: see section 5.3
Units: normalized, % percentage by weight, g/m
2
, lbs. p. l. mile
Request channels:
UMB Channel Measuring Range
act min max avg Measured Value Data Type min max Unit
830 835 Saline concent.MgCl2 uint16 0 65520 norm value
831 836 Saline concent.MgCl2 float32 0 100 %
911 916 Saline concent.MgCl2 float32 0 100 g/m
2
921 926 Saline concent.MgCl2 float32 0 1280 lbs.p.l.mile
6.1.13 Saline Concentration CaCl
2
2
Sampling rate: see section 5.3
Units: normalized, % percentage by weight, g/m
2
, lbs. p. l. mile
Request channels:
UMB Channel Measuring Range
act min max avg Measured Value Data Type min max Unit
840 845 Saline concent.CaCl2 uint16 0 65520 norm value
841 846 Saline concent.CaCl2 float32 0 100 %
912 917 Saline concent.CaCl2 float32 0 100 g/m
2
922 927 Saline concent.CaCl2 float32 0 1280 lbs.p.l.mile
6.1.14 Road Condition
Sampling rate: see section 5.3
Units: logical coding
Request channels:
UMB-Chanel Measuring Range
act min max avg Measured Value Data Type min max Unit
900 905 Road condition uint8 0 99
Coding Meaning Description
10 Dry There is no liquid water on the road or the water film height is below the dry-
moist threshold.
15 Moist There is liquid water on the road and the water film height is between the dry-
moist and moist-wet thresholds.
20 Wet There is liquid water on the road; the water film height has raised above the
moist-wet threshold.
25 Moist with salt Describes a moist road condition where the freezing temperature is lower than -
0.1°C.
30 Wet with salt Describes a wet road condition where the freezing temperature is lower than -
0.1°C.
35 Ice There is frozen water on the road, mostly in the form of ice or snow.
40 Snow There is snow on the road
45 Frost There is frost on the road
The factory settings for the moist and wet thresholds are 10 and 200 µm, respectively. These settings can
be adjusted in the sensor configuration (see screenshot).
2
experimental implementation