5
Flashing LED when battery power is low, overpressure or empty oil
reservoir
1. Product details
No. Description No. Description
1 Cover for oil reservoir 6 Drive
2 Oil reservoir 7 Turning knob
3 Return valve 8 Nonwoven fabric
4 Display 9 Thread male 3/8"
5 Dispensing setting 10 Reducer 3/8" x 1/4"
2. Technical data
Housing
Operating temperature
Alkaline battery:
Lithium battery:
+5 ... +60
-15 ... +60
°C
Dimensions (height x Ø) 229 x 94 mm
Lubricant and hydraulic
Lubricating medium oil (> ISO VG 10)
Lubricant volume 500 (rellable) ml
Number of lubrication points up to 10 by using progressive distributors*
Max. operating pressure 10 bar
Oil delivery per stroke 0,3 - 0,33 ml
Distribution period 0,5/1/2/4/6/12/18/24 months
Electrics
Working voltage (DC) 4,5 V
Protection class IP54
* The stated value depends on the individual application and may extensively dier in some
cases (depending on the lubricant and further conditions).
3. LCD & key assignment
Key assignment
MODE
LOCK
Dispensing time setting
Unlock device (press down for 2 seconds)
POWER
Switch device on and o (press down for 5 seconds)
TEST
Test mode (ON: press for 2 seconds, OFF: press briey - stops after the
end of the current lubrication cycle)
RESET
Reset to default setting when the unit is switched on or o (in the event
of a malfunction or after relling).
LCD-display
MONTH
Dispensing time set
500
Oil reservoir capacity
Device locked
Test mode
Number of days remaining until end of dispensing time
Amount of lubricant per day (in ml)
Number of days since end of dispensing time
In case of overpressure: number of days since operation was stopped
Overpressure / operation stopped
Low battery power
Oil reservoir empty
Turn the knob 1-2 turns
counterclockwise before closing
the cover and do not change
the position again during
operation.
Press POWER for 5 seconds to
switch on.
OPTIONAL: Press the TEST
button for 2 seconds to perform
a test run. Oil will leak out
during the test run.
After 30 seconds, the key lock
is activated. Press the MODE
button for 2 seconds to unlock
the unit.
Press the MODE button
several times to set the
desired dispensing time. The
display shows the amount of
lubrication per day.
The lubricator is ready for
operation. After the key
lock has been activated, the
remaining days of the runtime
are shown in the display.
Pull the dust protection cover
over the lubricator where
necessary.
If the lubricator is installed
below the lubrication point,
make sure that the lubri
-
cation lines are lled.
Remove the oil reservoir and
nonwoven fabric and insert
the battery. Put the nonwoven
fabric back in and screw the oil
reservoir back on.
Remove the lid of the oil
reservoir and ll it up to the
500 ml level with oil.
Fix the lubricator in the
desired position.
NOTE
The oil in the equipment (hose/feed lines) and the oil in
the unit should be the same or compatible.
9
Ensure that a thorough
pre-lubrication of the appli
-
cation is carried out before
activating the lubricator.
4. Installation