User manual

5
LOOP
PROG. CH.
34
MUTE
X1 OFF OFF OFF
X2 ON OFF OFF
X3 OFF ON OFF
X4 ON ON OFF
LOOP
PROG. CH.
1234
MUTE
100 ON ON ON ON ON
101 RESTORE OFF
X – every value from 0 to 9 range
The units’ digit of program number defines the state of LOOP3 and LOOP4,
the decimal digit of program number defines the state of LOOP1 and LOOP2.
Receiving of the command which units’ digit or decimal digit has out of range
value causes ignoring that digit(s) and considering the digit with correct value.
M4L can be controlled by individual Control Change type command or
individual controllers of particular functions. The table below shows the
Control Change commands functionality.
CONTROL CHANGE
NUMBER VALUE
0 - 63 LOOP1 OFF
80
64 - 127 LOOP1 ON
0 - 63 LOOP2 OFF
81
64 - 127 LOOP2 ON
0 - 63 LOOP3 OFF
82
64 - 127 LOOP3 ON
0 - 63 LOOP4 OFF
83
64 - 127 LOOP4 ON
0MUTE ON
7
1-127 MUTE OFF
CONTROL CHANGE
LOOP
NUMBER VALUE
12
MUTE
1X OFF OFF OFF
2X ON OFF OFF
3X OFF ON OFF
89
4X ON ON OFF