SDS
21/09/2016 EN (English US) 3/11
FVP ST
A
Y TUNED MULTI-SYSTEM
A
DDITIVE 16 FL.OZ.
Safety Data Sheet
according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations
Emergency procedures : Evacuate unnecessary personnel.
6.1.2. For emergency responders
Protective equipment : Equip cleanup crew with proper protection. Safety glasses. Protective gloves.
Emergency procedures : Ventilate area. Stop leak if safe to do so.
6.2. Environmental precautions
Avoid release to the environment. Notify authorities if product enters sewers or public waters. Notify authorities if liquid enters sewers or public
waters.
6.3. Methods and material for containment and cleaning up
For containment : Contain released substance, pump into suitable containers. Dam up the liquid spill. Plug the
leak, cut off the supply.
6.4. Reference to other sections
No additional information available
SECTION 7: Handling and storage
7.1. Precautions for safe handling
Additional hazards when processed : Handle empty containers with care because residual vapors are flammable.
Precautions for safe handling : No open flames. No smoking. Take precautionary measures against static discharge. Use only
non-sparking tools. Obtain special instructions . Do not handle until all safety precautions have
been read and understood.
Hygiene measures : Remove contaminated clothes. Do not eat, drink or smoke when using this product. Always
wash hands after handling the product. Wash contaminated clothing before reuse. Wash
affected areas thoroughly after handling. Separate working clothes from town clothes. Launder
separately.
7.2. Conditions for safe storage, including any incompatibilities
Technical measures : Proper grounding procedures to avoid static electricity should be followed. Ground/bond
container and receiving equipment. Use explosion-proof electrical, ventilating, lighting
equipment. Comply with applicable regulations.
Storage conditions : Keep container tightly closed.
Incompatible materials : Heat sources.
7.3. Specific end use(s)
Follow Label Directions.
SECTION 8: Exposure controls/personal protection
8.1. Control parameters
Distillates (Petroleum), H
y
drotreated Light (64742-47-8)
USA ACGIH ACGIH TWA (ppm) 200 ppm 8 Hours
Ethylbenzene (100-41-4)
USA ACGIH ACGIH TWA (ppm) 100 ppm
USA ACGIH ACGIH STEL (ppm) 125 ppm
USA OSHA OSHA PEL (TWA) (mg/m³) 435 mg/m³
USA OSHA OSHA PEL (TWA) (ppm) 100
USA OSHA OSHA PEL (STEL) (mg/m³) 545 mg/m³
USA OSHA OSHA PEL (STEL) (ppm) 125 ppm
Distillates (Petroleum), Hydrotreated Heavy Naphthenic (64742-52-5)
USA ACGIH ACGIH TWA (mg/m³) 5 mg/m³ MIST 8 HOURS
USA OSHA OSHA PEL (TWA) (mg/m³) 5 mg/m³ MIST 8 HOURS
2-Propanol (67-63-0)
USA ACGIH ACGIH TWA (mg/m³) 980 mg/m³
USA ACGIH ACGIH TWA (ppm) 400 ppm
USA ACGIH ACGIH STEL (mg/m³) 1225 mg/m³
USA ACGIH ACGIH STEL (ppm) 500 ppm
USA OSHA OSHA PEL (TWA) (mg/m³) 980 mg/m³
USA OSHA OSHA PEL (TWA) (ppm) 400 ppm
8.2. Exposure controls
Appropriate engineering controls : Local exhaust venilation, vent hoods . Ensure good ventilation of the work station.