Installation Manual

1
4
MONTAGGIO GRUPPO INCASSO INSERT-LINER INSTALLATION
2
M
M
Insert the ventilation unit into the bottom of the
Cut the opening & drill holes
cabinet/enclosure; the springs (M) will hold it in
as necessary for mounting.
place for ease of installation.
3
A
A
P
M
Open the panel (P) and tighten the screws (A) until the springs (M)
hold the ventilation unit securely against the cabinet panel
Connect the 3-pin power plug to the power outlet.
Complete the electrical connection ONLY after
disconnecting the electrical power (circuit breaker).
In the outside ventilation version, connect the output collar
of the blower the external duct.
In the recirculating version, attach the charcoal filters to
the blower motor.
Install the metal filters, and close the deflector panel.