Owner's Manual

amplifier to the battery. See the ABYC standards for the
required fuse or breaker rating.
If the amplifier is powered by a source other than a battery,
use a breaker or fuse rated no higher than the max current of
the power source.
Internal fuse rating
Internal electronic fuse. No replacement necessary.
MS-AP41200: 85 A
MS-AP61800, MS-AP82400: 125 A
Remote turn-on Greater than 4 Vdc
Protection circuits
Reverse voltage
Input under/over voltage
Over temperature
Output short circuit
Dimensions
NOTE: A MS-AP41200 amplifier is shown for illustration purposes. Refer to the table for model-specific
measurements.
MS-AP41200: 235 mm (9
1
/
4
in.)
MS-AP61800: 297 mm (11
11
/
16
in.)
MS-AP82400: 359 mm (14
1
/
8
in.)
180 mm (7
1
/
16
in.)
45 mm (1
3
/
4
in.)
16 Fusion Apollo Series Installation Instructions