3. INSTALLATION
20
How to set the cosmetic cap
Set a cosmetic cap to each fixing screw on the front panel as shown below.
3.3 Installation of Remote Controller and Dimmer
Controller
The optional remote controller RD-501 and dimmer controller RD-502 can be flush mounted in a
panel. The size and the mounting procedure are shared by RD-501 and RD-502. For the mounting
location, refer to the mounting considerations for the remote display in section 3.2.
Flush mounting
1. Make a cutout in the mounting location (88 mm (width) x 76 mm (height)).
2. Make four holes of φ4 in the location indicated in the illustration below.
3. Set the remote controller or dimmer controller to the cutout. Insert four binding head screws
(M3x12) from the front side then fasten the unit with four sets of flat washers, spring washers
and hexagonal nuts from the rear side.
Note: If it is more convenient to connect cables before you install the remote controller or dim-
mer controller, first connect the cables referring to the section 3.4.
Set cosmetic cap to hole so cap is flush with panel.
DISP
UNIT
MODE
REMOTE CONTROLLER
RD
-
501
88 ± 1.0 (3.46”)
86 ± 0.5 (3.39”)
76 ± 1.0 (2.99”)
Fixing hole (4-
φ
4)
86 ± 0.5 (3.39”)