OPERATOR'S MANUAL REMOTE DISPLAY MODEL RD-20 www.furuno.co.
IMPORTANT NOTICES General • This manual has been authored with simplified grammar, to meet the needs of international users. • The operator of this equipment must read and follow the descriptions in this manual. Wrong operation or maintenance can cancel the warranty or cause injury. • Do not copy any part of this manual without written permission from FURUNO. • If this manual is lost or worn, contact your dealer about replacement.
SAFETY INSTRUCTIONS WARNING Indicates a condition that can cause death or serious injury if not avoided. CAUTION Indicates a condition that can cause minor or moderate injury if not avoided. Safety Instructions for the Operator Safety Instructions for the Installer WARNING WARNING Turn off the power at the switchboard before you install the equipment. Do not disassemble or modify the equipment. Fire, electrical shock or serious injury can occur.
TABLE OF CONTENTS FOREWORD................................................................................................................ iv SYSTEM CONFIGURATION ........................................................................................ v 1. OPERATION .......................................................................................................... 1 1.1 1.2 1.3 1.4 1.5 1.6 1.7 2. MAINTENANCE, TROUBLESHOOTING ............................................................ 12 2.1 2.
FOREWORD A Word to the Owner of the RD-20 Remote Display Congratulations on your choice of the FURUNO RD-20 Remote Display. We are confident you will see why the FURUNO name has become synonymous with quality and reliability. For over 60 years FURUNO Electric Company has enjoyed an enviable reputation for innovative and dependable marine electronics equipment. This dedication to excellence is furthered by our extensive global network of agents and dealers.
SYSTEM CONFIGURATION Single remote display Remote display RD-20 FURUNO PWR DISP UNIT RD-20 MODE BRILL FURUNO 12-24 VDC DISP UNIT MODE FURUNO DAY NT BRILL NMEA0183 sensor signal REMOTE CONTROLLER DIMMER CONTROLLER RD-501 RD-502 Remote controller RD-501 Dimmer controller RD-502 Environmental category: Protected from weather: RD-20, RD-501, RD-502 v
SYSTEM CONFIGURATION Multiple remote displays (daisy chain connection) Pattern 1: Sensor signal and dimmer controller are commonly used. A total of 10 RD-20s can be connected.
1. OPERATION 1.1 Controls Remote display RD-20 RD-20 No. PWR DISP UNIT MODE 1 2 3 4 Control 5 Description 1 PWR Turn on/off the power. 2 DISP Switch the screen. 3 UNIT Select the units of measurement for the current screen. 4 MODE Select the mode for the current screen. 5 T, S T: Decrease the display brilliance. S: Increase the display brilliance. (See section 1.3 for details.) How to remove the hard cover Press here with thumb and pull cover forward.
1. OPERATION Remote controller RD-501 2 1 DISP UNIT MODE 3 REMOTE CONTROLLER RD- 501 No. Control Description 1 DISP Switch the screen. 2 UNIT Select the units of measurement for the current screen. 3 MODE Select the mode for the current screen. Dimmer controller RD-502 2 1 DAY NT BRILL DIMMER CONTROLLER RD- 502 No. Control Description 1 DAY/NT Switch the display brilliance between daytime use and nighttime use. 2 T, S T: Decrease the display brilliance.
1. OPERATION 1.2 How to Turn the Power On and Off Press the PWR key to turn on the power. The start-up screen appears, showing all LED dots and 7-segments. Then, the model name, and then the results of the ROM and RAM check, OK or NG (No Good), are shown. After the self-tests are completed, the last-used display appears. FURUNO RD-20 ROM RAM OK OK 8.8.8.8.
1. OPERATION 1.4 How to Select a Screen Screen The screen for the RD-20 changes as follows with the DISP key. When you start the RD-20, the last-used screen appears. Availability of data depends on your system configuration. Display mode (AUTO, SOG, STW, GPS) SOG AUTO AFT kn Direction of ship’ s movement (AFT or : After, FWD or : Forward) AUTO appears when display mode is “AUTO”. 25.9 Speed (default) DISP key Distance run Display mode (AUTO, SOG, STW, GPS) “A” means AUTO mode. 23456.
1. OPERATION (Continued from previous page) Direction of ship’ s turn (STBD or : Starboard side, PORT or : Port side, No indication: When 0.0 or 180.0 deg) RUDDER P STBD deg Current rudder position (S: STBD (starboard), P : PORT, No indication: SINGLE) 9.4 Rudder angle DISP key Direction of ship’ s turn (STBD or : Starboard side, PORT or : Port side, No indication: When 0.0 or 180.0 deg) ORDER P STBD deg Current rudder position (S: STBD (starboard), P : PORT, No indication: SINGLE) 9.
1. OPERATION List of terms The following table shows the terms used in the RD-20. Term Meaning % Percent °C °F 1AXIS Degree(s) Celsius Degree(s) Fahrenheit 1-axis 7-SEG 38.4k 4.8k 7-Segment 38.4Kbps 4.
1. OPERATION Term MENU Menu Meaning mph m/s NG Miles per hour Meter/second No Good NM No. NO Nautical Mile Number No NT OFF OFFSET Night Off Offset OK ON ORDER OK On Rudder Angle Order OUT PITCH P, PORT Output Propeller Pitch Port/Port Side PWR R RAM RANK Power Relative: Relative or apparent wind. The wind direction relative to the ship’s bow and the wind speed relative to the moving vessel.
1. OPERATION 1.5 How to Select the Units of Measurement You can select the units of measurement for speed, distance, depth, wind speed and water temperature. 1. Press the DISP key to display the screen which you want to change the units of measurement. 2. Press the UNIT key to select the unit desired.
1. OPERATION • Heading: True (default, display indication: none), Magnetic (display indication: "MAG") Display mode (No indication: True, MAG: Magnetic) HDG MAG deg 135.4 • Course over the ground: True (default, display indication: none), Magnetic (display indication: "MAG") Display mode (No indication: True, MAG: Magnetic) COG MAG deg 30.9 • Depth: AUTO (default), DBK, DBT, DBS In the [AUTO] mode, the highest priority data is DBK and the lowest is DBS.
1. OPERATION 1.7 How to Set the User Menu The user menu lets you adjust the RD-20 to meet your needs. No. Menu Description Setting Default 1 KEY LED BRILL Set the brilliance for key LED. 1 to 8 8 2 RPM SET ENGINE (or SHAFT, PITCH) Select the engine-related data to show from [ENGINE], [SHAFT], or [PITCH]. ENGINE, SHAFT, PITCH ENGINE 3 RPM SET No. Select the number of engine, shaft, or propeller.
1. OPERATION KEY LED BRILL 8 UNIT key 1 Set the brilliance for key LED using or key. MODE key 2 Select an item to display among [ENGINE], [SHAFT], or [PITCH]. RPM SET ENGINE key RPM SET SHAFT key RPM SET PITCH key UNIT key MODE key RPM SET No. 0 3 Select the number of engine, shaft or propeller using or key. MODE key UNIT key WIND AVE TIME 1 UNIT key 4 Set the wind average processing time (min) using or key. MODE key 5 Select the mounting location of rudder.
2. MAINTENANCE, TROUBLESHOOTING NOTICE Do not apply paint, anti-corrosive sealant or contact spray to coating or plastic parts of the equipment. Those items contain organic solvents that can damage coating and plastic parts, especially plastic connectors. 2.1 Maintenance Check the following points regularly to maintain performance: • Check that connections on the rear panel are firmly tightened and free of dust. • Check that the ground system is free of rust and the ground wire is tightly fastened.
2. MAINTENANCE, TROUBLESHOOTING 2.2 Life of the Parts Fuse replacement The fuse in the remote display protects the equipment from overcurrent and equipment fault. If the fuse blows, find the cause before you replace the fuse. Use the correct fuse. A wrong fuse can damage the equipment. See the outline drawings about the location of the fuse. WARNING Use the correct fuse. A wrong fuse can damage the equipment and cause fire. Type Code No.
2. MAINTENANCE, TROUBLESHOOTING While holding down the UNIT key, press the PWR key to turn on the power. Start screen for automatic test SELECT AUTO LOOPBACK CH2 Serial loopback test for CH2* MODE key (Automatic test starts.) Model name LED test pattern 1 LED test pattern 2 ROM/RAM test FURUNO RD-20 *: When loopback test is OK, “OK” appears. When loopback test is NG, there is no indication. LOOPBACK CH1 RD-502 2651009- 8.8.8.8.
2. MAINTENANCE, TROUBLESHOOTING 3. Press the MODE key. 4. Press each key except the PWR key. You can test up to 10 keys. The key name for the key pressed and the number of keys remaining to test are displayed. When the count is 0, the start screen for the key test appears. When testing more than 10 keys, repeat steps 3 and 4. While holding down the UNIT key, press the PWR key to turn on the power.
2. MAINTENANCE, TROUBLESHOOTING 2.
2. MAINTENANCE, TROUBLESHOOTING Parts List ELECTRICAL PARTS PRINTED CIRCUIT BOARD Model RD-20 Unit Remote display RD-20 Code No. - 26P0008, PNL 26P0009, MAIN ELECTRICAL PARTS PRINTED CIRCUIT BOARD Model RD-501 Unit Remote controller RD-501 Code No. - 26P0012A, RMT ELECTRICAL PARTS PRINTED CIRCUIT BOARD Model RD-502 Unit Dimmer controller RD-502 Code No.
3. INSTALLATION 3.1 Equipment List Standard supply Name Type Code No. Qty - 1 Remote Display RD-20 Installation Materials CP26-01001* 001-076-460-00 1 Accessories FP26-00301* 001-076-470-00 1 Spare Parts SP26-00101* 001-076-450-00 1 Remarks Optional supply Name Type Code No. Remarks Remote Controller RD-501 - Including CP26-01101* Dimmer Controller RD-502 - Including CP26-01201* Hanger OP26-1* 000-016-195-00 *: See the Packing lists. 3.
3. INSTALLATION Flush mounting 1. Make a cutout in the mounting location (132 mm (width) x 120 mm (height)). 2. Make four pilot holes for self-tapping screws (diameter: 3 mm) in the location indicated in the illustration below. 3. Insert the sponge to the remote display from the rear side. 4. Set the remote display to the cutout and fasten the remote display with four self-tapping screws (M3x15). 5. Set a cosmetic cap to each fixing screw on the front panel. (See “How to set the cosmetic cap” on page 20.
3. INSTALLATION How to set the cosmetic cap Set a cosmetic cap to each fixing screw on the front panel as shown below. Set cosmetic cap to hole so cap is flush with panel. 3.3 Installation of Remote Controller and Dimmer Controller The optional remote controller RD-501 and dimmer controller RD-502 can be flush mounted in a panel. The size and the mounting procedure are shared by RD-501 and RD-502. For the mounting location, refer to the mounting considerations for the remote display in section 3.2.
3. INSTALLATION 3.4 Wiring Interconnection Refer to the interconnection diagram (page S-1) to connect cables. Single remote display Remote display RD-20 + 11 1 2 11 10 9 8 7 6 5 4 3 2 1 - 12 φ4 DPYC-1.5 12-24 VDC TTYCS-1 (max. 100 m) Ground terminal Sensor signal RD1A 7 IV-1.
3. INSTALLATION Multiple remote displays (daisy chain connection) Pattern 1: Sensor signal and dimmer controller are commonly used. A total of 10 RD-20s can be connected in a daisy chain. A maximum of nine sub RD-20s can be connected.
3. INSTALLATION Pattern 2: Dimmer controller is commonly used. A total of 10 RD-20s can be connected in a daisy chain. A maximum of nine sub RD-20s can be connected.
3.
3. INSTALLATION How to connect wires to WAGO connector Press downward. Terminal opener Wire Twist WAGO connector Procedure 1. Twist the cores. 2. Press the terminal opener downward. 3. Insert the wire to hole. 4. Remove the terminal opener. 5. Pull the wire to confirm that it is secure. Attach the WAGO connectors (with cables). Bind the sheaths of cables to the fixture with the cable ties.
3. INSTALLATION 3.5 Adjustments After wiring each unit, initialize each remote display as follows: 1. While you hold down the MODE key, press the PWR key to turn on the power. SYS MENU NO MODE Note: If you press the MODE key with this screen shown, the equipment restarts. 2. Press T key to select the screen for [YES]. SYS MENU YES MODE 3. Press the MODE key. The screen for speed appears. 4. Press T or S key to change the setting. 5. Press the MODE key to go to the next screen.
3. INSTALLATION MODE key + PWR key The equipment restarts. MODE key SYS MENU NO MODE UNIT key Default key key key key 1 SPEED VECTOR Set the speed ([1 AXIS] or [VECTOR]). MODE key UNIT key Default key DIMMER MAIN UNIT key key DIMMER SUB MODE key Default NoChkSUM Disable UNIT key Default key key NoChkSUM Enable 2 Select [MAIN] or [SUB]. 3 Select whether to receive the nonchecksum data or not. MODE key BAUD - RATE CH1 4.8k key key UNIT key BAUD - RATE CH2 4.
3. INSTALLATION No. 1 Menu SPEED Description • [1 AXIS]: Display FWD/AFT speed. Forward: FWD (↑), After: AFT (↓) • [VECTOR]: Do not display the direction of the ship’s movement. Default [1 AXIS] Note: The [VECTOR] speed consists of forward/after speed of the ship and the influence of tidal current/wind. Requires multiaxis speed data. 2 DIMMER • [MAIN]: Set the unit which is connected to the dimmer controller in the daisy chain connection as the main unit.
3. INSTALLATION 3.6 JIS Cable Guide Cables listed in the manual are usually shown as Japanese Industrial Standard (JIS). Use the following guide to locate an equivalent cable locally. JIS cable names may have up to 6 alphabetical characters, followed by a dash and a numerical value (example: DPYC-2.5). For core types D and T, the numerical designation indicates the cross-sectional Area (mm2) of the core wire(s) in the cable.
FURUNO RD-20 SPECIFICATIONS OF REMOTE DISPLAY RD-20 1 1.1 1.2 1.3 REMOTE DISPLAY Display type Brilliance Data indication Segment LED and dot matrix (red) 10 steps (includes ‘OFF’) Ship’s speed, Course, Heading, Distance, Depth, Rate of turn, Wind direction/speed, Rudder angle, Engine/ shaft RPM, Propeller pitch, Water temperature 1.4 Remote control Remote controller (option) required 1.5 Remote dimmer Dimmer controller (option) required 1.
A-1 工事材料表 CODE NO. 001-076-460-00 TYPE CP26-01001 26AB-X-9401 -1 1/1 REMOTE DISPLAY RD-20 INSTALLATION MATERIALS 番 号 NO. 名 称 NAME 略 図 OUTLINE 型名/規格 DESCRIPTIONS 数量 Q'TY 用途/備考 REMARKS Fマウントスポンジ 1 26-004-1201-0 FLUSH MOUNTING SPONGE 1 CODE NO. 100-350-750-10 +バインドタッピン1シュ 2 3X16 SUS304 TAPPING SCREW 4 CODE NO. 000-171-996-10 コンベックス 3 CV-150B CABLE TIE 9 CODE NO. 000-167-183-10 圧着端子 4 FV2-4 CRIMP-ON LUG 3 CODE NO. 000-157-247-10 圧着端子 5 FV5.
A-2 付属品表 CODE NO. 001-076-470-00 TYPE FP26-00301 26AB-X-9501 -1 1/1 REMOTE DISPLAY RD-20 ACCESSORIES 番 号 NO. 名 称 NAME 略 図 OUTLINE 型名/規格 DESCRIPTIONS 数量 Q'TY 用途/備考 REMARKS フィルタークリーナー 1 02-155-1082-1 LCD CLEANING CLOTH 1 CODE NO. 100-332-651-10 ネジキャップ 2 26-004-1255-1 CAP 4 CODE NO. 100-353-651-10 型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりません。 TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. QUALITY IS THE SAME.
A-3 CODE NO. 001-076-450-00 26AB-X-9301 -1 1/1 TYPE SP26-00101 BOX NO. SPARE PARTS LIST FOR SHIP NO. U S P SETS PER VESSEL E REMOTE DISPLAY RD-20/RD-50,DS-600 ITEM NO. NAME OF PART OUTLINE DWG. NO. OR TYPE NO. QUANTITY REMARKS/CODE NO. WORKING PER SET PER VES SPARE ヒューズ 1 2 GLASS TUBE FUSE MFR'S NAME FGMB 125V 2A PBF FURUNO ELECTRIC CO.,LTD. 000-157-479-10 DWG NO. 26AB-X-9301 1/1 (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.
A-4 工事材料表 CODE NO. 001-076-990-00 TYPE CP26-01101 26AC-X-9401 -1 1/1 REMOTE CONTROLLER RD-501 INSTALLATION MATERIALS 番 号 NO. 名 称 NAME 略 図 OUTLINE 型名/規格 DESCRIPTIONS 数量 Q'TY 用途/備考 REMARKS コンベックス 1 CV-150B CABLE TIE 4 CODE NO. 000-167-183-10 圧着端子 2 FV2-4 CRIMP-ON LUG 1 CODE NO. 000-157-247-10 圧着端子 3 FV5.5-4(LF) CRIMP-ON LUG 2 CODE NO. 000-166-744-10 六角ナット 1シュ 4 M3 SUS304 HEXAGONAL NUT 4 CODE NO. 000-167-477-10 ミガキ丸平座金 5 M3 SUS304 FLAT WASHER 4 CODE NO.
A-5 工事材料表 CODE NO. 001-077-000-00 TYPE CP26-01201 26AC-X-9402 -1 1/1 DIMMER CONTROLLER RD-502 INSTALLATION MATERIALS 番 号 NO. 名 称 NAME 略 図 OUTLINE 型名/規格 DESCRIPTIONS 数量 Q'TY 用途/備考 REMARKS コンベックス 1 CV-150B CABLE TIE 2 CODE NO. 000-167-183-10 圧着端子 2 FV2-4 CRIMP-ON LUG 1 CODE NO. 000-157-247-10 圧着端子 3 FV5.5-4(LF) CRIMP-ON LUG 1 CODE NO. 000-166-744-10 六角ナット 1シュ 4 M3 SUS304 HEXAGONAL NUT 4 CODE NO. 000-167-477-10 ミガキ丸平座金 5 M3 SUS304 FLAT WASHER 4 CODE NO.
A-6 CODE NO. 000-016-195-00 TYPE OP26-1 26AB-X-9402 -0 1/1 REMOTE DISPLAY RD-20 明細書 DESCRIPTION 番 号 NO. 名 称 NAME +トラスタッピンネジ 1 型名/規格 DESCRIPTIONS 略 図 OUTLINE 数量 Q'TY 用途/備考 REMARKS 1シュ SELF-TAPPING SCREW 4X16 SUS304 CODE NO. 4 000-162-605-10 +バインドコネジ 2 BINDING HEAD SCREW M3X12 SUS304 CODE NO. 4 000-171-998-10 ハンガー組品 3 HANGER ASSY. OP26-1-1 CODE NO. 1 001-076-490-00 型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりませ ん。 TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM.
D-1
D-2
D-3
D-4
S-1 1 2 TO USE NMEA DATA JOINTLY 12 *1 TTYCS-4 P P P *1 IV-1.25sq. DPYC-1.5 *1 12-24VDC 1 2 3 4 5 6 7 8 9 P (W/O RD-501) A Vout 1 GND 2 RD2A 3 RD2B 4 TD2A 5 TD2B 6 RD1A 7 RD1B 8 NC 9 NC 10 DC_H 11 DC_C 12 *1 TTYCS-4 リモートディスプレイ REMOTE DISPLAY RD-20 MAX.30m 1) NMEAデータを共有する場合 3 TTYCS-1 *1 NMEA0183 9 *1 IV-1.25sq.
*00017201211* *00017201211*