Installation Instructions

3. INITIAL SETTINGS
3-37
3.16 SYSTEM SETUP Menu
SAVE ENGINNER SETTING: Save the settings in the menus with the following excep-
tions:
DISPLAY SETUP (except DATA BOX FORMAT, TEMP GRAPH)
DOCKSIDE SETUP (except SELECT RRU TYPE, RRU SENSOR ALIGNMENT,
AIR BLEEDING, RUDDER LIMIT SETUP, RUDDER TEST, HELM SENSOR TEST)
CAN BUS SETUP (except INCOMING CAN BUS DATA, REFRESH)
NMEA 0183 SETUP PORT1, PORT2 (except REFRESH)
SENSOR SELECTION (except AUTO DETECT)
SEA TRIAL (except COMPASS, COMPASS CALIB., RESTART PG-700, COM-
PASS CLEAR, COMPASS INFORMATION, SET CENTER RUDDR POS)
SYSTEM SETUP (KEY BEEP, BUZZER VOL, KEY LOCK, PANEL DIMMER,
RECEIVE SCREEN, ALL CLEAR, SAVE/LOAD USER SETTINGS, SAVE/LOAD
ENGINEER SETTING, DIAGNOSTIC, DISPLAY DATA SELECT MENU, SYSTEM
DATA)
ALARM MENU (CLEAR TRIP LOG)
LOAD ENGINEER SETTING: Load the settings saved with SAVE ENGINEER SETTING:
For other items, section 4.6 “SYSTEM SETUP menu” in the Operator’s Manual.
Page 1
SYSTEM SETUP
KEY BEEP: OFF
BUZZER VOL: LARGE
ARROW KEY: DODGE
KEY LOCK: UNLOCK
TURN ANGLE: 15
PANEL DIMMER: 8
PASSWORD: 0000
PASSWORD FUNCTION: OFF
ALARM CLEAR
RECEIVE SCREEN: OFF
SAVE USER SETTING: NO
LOAD USER SETTING: NO
SAVE DISPLAY SETTINGS: NO
SYSTEM SETUP
LOAD DISPLAY SETTINGS: NO
SAVE ENGINEER SETTING: NO
LOAD ENGINEER SETTING: NO
ALARM LOG
SIM/DEMO: OFF
DIAGNOSTIC: OFF
DISPLAY DATA SELECT MENU
SYSTEM DATA
Page 2