Installation Instructions

2. WIRING
2-11
2.4.2 Prohibited remote controller connections
The remote controller combinations shown in this section are not allowed.
Wrong connection no.1
You cannot connect different types of remote controllers.
Wrong connection no.2
Connect only one dial-type remote controller.
Wrong connection no.3
You cannot connect multiple distributors.
FAP-6211 (button)
PROCESSOR UNIT
FAP-6221 (lever)
FAP-6231 (dodge)
FAP-6211 (button)
FAP-6221 (lever)
FAP-6231 (dodge)
FAP-5551 (dial)
PROCESSOR UNIT
FAP-5551 (dial)
FAP-5551 (dial)
FAP-5551 (dial)
PROCESSOR UNIT