OPERATOR'S MANUAL 取 扱 説 明 書 MONITOR UNIT 表示部 MODEL MU-190 www.furuno.
(Elemental Chlorine Free) The paper used in this manual is elemental chlorine free. ・ 機器の修理・使用方法等に関するお問い合わせは、お買い上げの販売店・代理店、最寄りの 当社支店・営業所あてへお願いします。 ・ FURUNO Authorized Distributor/Dealer 本書の無断複写複製(コピー)は特定の 場合を除き、当社権利侵害になります。 Printed in Japan Pub. No. OMC-44670-A1 ( YOTA) MU-190 A : MAY 2011 A1 : JUL.
IMPORTANT NOTICES General • This manual has been authored with simplified grammar, to meet the needs of international users. • The operator of this equipment must read and follow the descriptions in this manual. Wrong operation or maintenance can cancel the warranty or cause injury. • Do not copy any part of this manual without written permission from FURUNO. • If this manual is lost or worn, contact your dealer about replacement.
SAFETY INSTRUCTIONS Read these safety instructions before you operate the equipment. WARNING Indicates a condition that can cause death or serious injury if not avoided. CAUTION Indicates a condition that can cause minor or moderate injury if not avoided. Warning, Caution Mandatory Action Prohibitive Action Safety Instructions for the Operator WARNING WARNING Immediately turn off the power at the switchboard if water leaks into the equipment or something is dropped into the equipment.
SAFETY INSTRUCTIONS Safety Instructions for the Installer CAUTION WARNING Observe the following compass safe distances to prevent interference to a magnetic compass: Turn off the power at the switchboard before beginning the installation. Fire or electrical shock can result if the power is left on. Do not install the equipment where it may get wet from rain or water splash. MU-190 Standard compass Steering compass 1.65 m 1.
TABLE OF CONTENTS Note: This manual contains both English and Japanese instructions. The Installation Materials, Outline Drawings, and Interconnection Diagram are located at the back of this manual. FOREWORD ................................................................................................................. v SYSTEM CONFIGURATION ....................................................................................... vi EQUIPMENT LISTS ............................................................
FOREWORD A Word to the Owner of the MU-190 FURUNO Electric Company thanks you for purchasing the MU-190 19” Monitor Unit. We are confident you will discover why the FURUNO name has become synonymous with quality and reliability. For over 60 years FURUNO Electric Company has enjoyed an enviable reputation for quality and reliability throughout the world. This dedication to excellence is furthered by our extensive global network of agents and dealers.
SYSTEM CONFIGURATION RGB FSV-30/30S, etc. DVI (2 ports) FAR-21x7, FEA-2107, FCR-21x7, etc. VIDEO (NTSC/PAL) CCD camera, DVD recorder, etc. RS-232C 100-230 VAC MONITOR UNIT MU-190 FEA-2107, FCR-21x7, etc.
EQUIPMENT LISTS Standard supply Name Monitor Unit Installation Materials Type MU-190 CP26-01600 Code No. 000-019-210 Qty 1 1 set Accessories FP26-00401 001-080-780 1 set Spare Parts SP26-00501 001-116-240 1 set Remarks • Installation Materials (CP26-01601, Code No.: 001-116-250, See page A-1.) • Cable Assembly (DVI-D/D S-LINK 5M, Code No.: 001-132-960-10) LCD Cleaning Cloth (19-028-3125, Code No.: 100-360-671-10) Glass Tube Fuse (FGBO 250V 1A PBF, Code No.: 000-155-828-10) 3 pcs.
1. MOUNTING, WIRING 1.1 Preparation Mounting method You can install the monitor unit as follows. See the outline drawings at the back of this manual for mounting dimensions. • Flush mount, fixed at front (standard) • Flush mount, fixed at front, with hood (option) • Flush mount, fixed at rear (option) • Flush mount, fixed at rear, with hood (option) • Tabletop mount (option, hood-mountable) • Flush mount a series side by side, fixed at rear Note 1: The face of the LCD is made of glass.
1. MOUNTING, WIRING 1.2 Flush Mount, Fixed at Front Flush mount, fix at front is the standard installation method. 1. Use the flush mounting template (supplied) to make a cutout in the mounting location. 2. Attach the flush mounting sponges H19 and V19 to the back of the monitor unit in the order shown in the figure at right. Flush Mounting Sponge H19 (5 mm) for top and bottom Flush Mounting Sponge V19 (2 mm) for left and right 3.
1. MOUNTING, WIRING 7. Set the masking panel to each side of the monitor unit. Masking Panel for 19” LCD How to attach or detach the masking panel for 19” LCD Do the following to attach or detach the masking panel for 19” LCD. Reverse view of masking panel for 19” LCD a b Tab A Front side of monitor unit c Set the masking panel for 19” LCD to each side of the monitor unit. Attach each tab A to the monitor unit. Be careful not to break the tabs. To attach, follow order of right arrow (→).
1. MOUNTING, WIRING 1. Use the flush mounting template (supplied) to make a cutout in the mounting location. 2. Follow steps 2 to 6 in section 1.2. 3. Loosely fix the knobs (4 pcs.) to the hood fixing plates (19) from inside the plates. Knob Hood Fixing Plate (19) 4. Remove the binding head screws (M3x5, 6pcs.) and the side panel bases (6 pcs.) from the flush mount panels 19 attached to the monitor unit. Side Panel Base (6 pcs.) Binding Head Screw (6 pcs.) Flush Mount Panel 19 5.
1. MOUNTING, WIRING 7. Set the cutouts of the hood (19) assembly to the knobs on the hood fixing plates (19). Knob (4 pcs.) Hood (19) Assembly Hood Fixing Plate 19 Cutout (4 places) 8. Press the top of the hood (19) assembly to set the knobs in the cutouts. Press Press 9. Set the hood (19) assembly with the knobs tightly (4 pcs.). 1.4 Flush Mount, Fixed at Rear The flush mount, fixed at rear method requires the flush mount kit OP26-12 (option, see page vii). 1.
1. MOUNTING, WIRING 3. Screw the wing bolts and the wing nuts of the flush mount fixture 19 so that the protector for screw moves to the fixing plate. Wing Bolt Wing Nut Fixing Plate Protector for Screw Flush Mount Fixture 19 Move to the fixing plate. 4. Connect all cables at the back of the monitor unit. See section 1.8. 5. Set the monitor unit to the cutout. 6. Fasten the flush mount fixture 19 to the right and left sides of the rear of the monitor unit with the washer head screws B (6 pcs.).
1. MOUNTING, WIRING 1.5 Flush Mount, Fixed at Rear, with Hood The flush mount, fixed at rear method allows you to attach a hood assembly OP26-6 (option) to the monitor unit. Hood assembly OP26-6 (Code No.: 001-080-930) Name Hood (19) Assembly Flush Mounting Sponge V 19 Hood Fixing Plate 19 F-Mount Hood Packing 19 Knob M4 Flat Head Screw Flush Mounting Template Type OP26-6-1 26-005-3124 26-005-3302 26-005-3305 03-163-2303 M3x8 C42-00910 Code No.
1. MOUNTING, WIRING 6. Set the cutouts of the hood (19) assembly to the knobs on the hood fixing plates 19. Knob (4 pcs.) Hood (19) Assembly Hood Fixing Plate 19 Cutout (4 places) 7. Press the top of the hood assembly to set the knobs in the cutouts. Press Press 8. Set the hood assembly with the knobs tightly (4 pcs.). 1.6 Tabletop Mount You can fix the monitor unit to a tabletop, using the bracket assembly OP26-5 (option). Bracket Assembly OP26-5 (Code No.
1. MOUNTING, WIRING 2. Set the mounting bracket to the mounting location with four self-tapping screws. Self-Tapping Screw (4 places) Mounting Bracket (19) 3. Attach the bracket support to the rear of the monitor unit with the binding head screws (9 pcs.). Bracket Support w/Knobs Binding Head Screw (9 places) Binding Head Screw Rear view 4. Connect all cables at the back of the monitor unit. See section 1.8. 5.
1. MOUNTING, WIRING 1.7 Flush Mount a Series Side by Side You can flush mount two or three monitor units side by side, using the optional flush mount kit OP26-13 for two monitor units or OP26-14 for three monitor units (see page vii). 1. Make a cutout in the mounting location as shown below (see page D-4). (9) 389±1 4-Ø18 1342±1 4-Ø18 (9) (9) (9) 389 ±1 892±1 For two monitor units For three monitor units 2. Follow steps 2 to 5 in section 1.
1. MOUNTING, WIRING 1.8 Wiring Refer to the figure below and the interconnection diagram at the back of this manual to connect cables. Connector Attach the Terminal Board Gear Cover again after connecting cables. Power switch The bottom of the rear of the monitor unit IV-8 sq (local supply) *1 Slide switch *2 Composite signal cable Fuse CCD camera DVD recorder To ground terminal on hull DPYC-1.
2. ADJUSTMENTS Adjust the MU-190 according to the equipment connected. Note: Sections 2.2, 2.3 and 2.4 are for Non-SOLAS. 2.1 Installation Settings The [INSTALLATION SETTING] menu appears only when the power is turned on for the first time after installation.
2. ADJUSTMENTS 1. Press the S or T key to select the menu item to adjust on the [INSTALLATION SETTING] menu. The menu item and setting currently selected (the cursor) is shown in orange. 2. Press the W or X key to change the setting. 3. After you adjust all settings, press the T key to select [SAVE AND EXIT]. The confirmation message appears.
2. ADJUSTMENTS How to open the [INSTALLATION SETTING] menu Turn off the monitor unit. While you hold the DISP key, press the /BRILL key to turn on the monitor unit. Press and hold the DISP key for more than five seconds. Note: When the "DVI PWR SYNC" slide switch is ON, turn on the connected external equipment while you press the DISP key to turn on the monitor unit. 2.2 RGB/DVI Setting (For Non-SOLAS) You can adjust the screen from the RGB, DVI-D1 and DVI-D2 ports individually.
2. ADJUSTMENTS [RGB], [DVI1/2] menu descriptions Menu item H_SIZE (Only for RGB menu) V_SIZE (Only for RGB menu) PHASE** (Only for RGB menu) BRIGHTNESS CONTRAST H_POSITION V_POSITION R_LEVEL G_LEVEL B_LEVEL TEMPERATURE B STRETCH W STRETCH DISP MODE* SHARPNESS** Function Adjust the image size horizontally. Horizontal size: W (narrow), X (wide) Adjust the image size vertically. Vertical size: W (narrow), X (wide) Adjust the sample timing so that the flicker disappears and the text is clear.
2. ADJUSTMENTS 2.3 Video Composite Signal Setting (For Non-SOLAS) You can adjust the VIDEO signal from the VIDEO port. The VIDEO signal is also displayed in the PIP window (see section 3.5). 1. Select the signal to adjust at the DISP selection window. 2. Press the MENU key to show the menu. 3. Press the W or X key to select [VIDEO].
2. ADJUSTMENTS 2.4 The Menu Window Setting (For Non-SOLAS) 2.4.1 How to adjust the menu window You can adjust the position and transparency of the menu window on the [OSD] (On Screen Display) menu. 1. Press the MENU key to show the menu. 2. Press the W or X key to select [OSD]. RGB DVI1 H_POSITION V_POSITION TRANSLUCENT CUSTOM NAME RGB : DVI1 : DVI2 : VIDEO : DVI2 VIDEO OSD SYSTEM 14 (1~29) 33 (1~37) OFF (OFF/ON) RGB DVI1 DVI2 VIDEO 3. Press the S or T key to select the menu item to adjust.
2. ADJUSTMENTS 2.4.2 How to change the signal name You can change the signal name ([RGB], [DVI1/2] or [VIDEO]) to a name (ex. the equipment name) which is easy to understand. The name is shown in the DISP selection window and the indication shown at the upper right of the screen (see section 3.4). 1. Press the MENU key to show the menu. 2. Press the W or X key to select [OSD]. 3. Press the S or T key to select the signal to change its name in the signal name area. In the example below, [RGB] is selected.
3. OPERATION Note: When you connect the monitor unit to FAR-21x7, FEA-2107 or FCR-21x7, you can turn the power on/off and adjust the brilliance via the application of the FAR-21x7, FEA-2107 or FCR-21x7 only (see section 2.1). 3.1 Controls MENU Open/Close the menu. DISP BRILL Select the signal to display. MENU Light sensor (Automatically detect the ambient brightness.) PIP DISP - Select the menu and menu items. - Adjust the setting. - Move the PIP window. - Power On/Off.
3. OPERATION Slide switch “ON” The external equipment connected to the DVI port (DVI-D1 or DVI-D2) can turn on/off the monitor unit. See the operator’s manual for the external equipment connected. Note 1: You can not turn on the power with the /BRILL key on MU-190. Note 2: When you connect the cables to both DVI-D1 and DVI-D2 ports, turn off the power of both equipment to turn off the monitor unit. Slide switch “OFF” 1. Press the /BRILL key to turn on the monitor unit. 2.
3. OPERATION 3.4 How to Select the Source for Main Picture Select the signal to display on the entire screen as follows: 1. Press the DISP key to show the DISP selection window. The window shows the signal names as you customized them at paragraph 2.4.2. This window disappears if there is no operation for five seconds. 2. Press the S or T key to select a signal. [RGB]: Show the signal from the RGB port. [DVI1], [DVI2]: Show the signal from the selected DVI port.
3. OPERATION 2. Press the X key to select [SYSTEM]. RGB DVI1 DVI2 VIDEO OSD AUTO DIMMER DEFAULT RESET OFF (OFF, 1~5) NO (NO YES) INFORMATION RGB DVI1 DVI2 VIDEO SERIAL No. APR PROGRAM No. FPGA PROGRAM No. ELAPSED TIME : : : : : : : : SYSTEM 1280*1024 Fh : 80.0kHz Fv : 75Hz 1280*1024 Fh : 64.0kHz Fv : 60Hz NO SIGNAL NTSC 8073-5578, 987655 2651020-01.XX 2651021-01.XX 100000 Signal status, serial number, program number and elapsed time 3. Press the S or T key to select [AUTO DIMMER]. 4.
4. MAINTENANCE, TROUBLESHOOTING NOTICE Do not apply paint, anti-corrosive sealant or contact spray to coating or plastic parts of the equipment. Those items contain organic solvents that can damage coating and plastic parts, especially plastic connectors. 4.1 Maintenance Routine maintenance Regular maintenance is important for good performance. Check the following on a regular basis to keep the equipment in good condition.
4. MAINTENANCE, TROUBLESHOOTING Item Life Approximately 40,000 hours Approximately 60,000 hours FAN1 FAN4 4.2 Type MFB52A-12HA-001 LQ0DDB0094 Code Number 000-172-023-10 000-172-144-10 Troubleshooting See the following table to find the possible causes of trouble and the actions to restore normal operation. If repair of the equipment is necessary, report the result of the troubleshooting to the service technician. Case You can not turn on the power. You can not turn off the power. No picture 4.
FURUNO MU-190 SPECIFICATIONS OF MONITOR UNIT MU-190 1 GENERAL 1.1 Display 19-inch color LCD 1.2 Effective area 376.32 x 301.06 mm 1.3 Resolution SXGA (1280 x 1024 pixel) 1.4 Pixel pitch 0.294 mm (Horizon/Vertical) 1.5 Brightness 450 cd/m2 typical 1.6 Contrast 900: 1 1.7 View angle 160° (up/down, left/right 80° or more) 1.8 Visible distance 1.02 m nominal 1.9 Input signal 2 RGB analog 1 port, non-interlace, RGB signal: 0.7 Vp-p, Sync.
A-1 CODE NO. 001-116-250-00 TYPE CP26-01601 26AH-X-9401 -2 1/1 工事材料表 MU-190 INSTALLATION MATERIALS 番 号 NO. 名 称 NAME 略 図 OUTLINE 型名/規格 DESCRIPTIONS 数量 Q'TY 用途/備考 REMARKS FマウントスポンジV19 1 26-005-3124-0 FLUSH MOUNTING SPONGE V 19 2 CODE NO. 100-351-560-10 化粧パネル19 2 26-007-1124-2 MASKING PANEL FOR 19" LCD 2 CODE NO. 100-363-462-10 FマウントスポンジH19 3 26-007-1127-0 FLUSH MOUNTING SPONGE H19 2 CODE NO. 100-363-240-10 +トラスタッピンネジ 1シュ 4 5X20 SUS304 SELF-TAPPING SCREW 4 CODE NO.
20/May/2011 Y.
3/Mar/2011 Y.
3/Mar/2011 Y.
1/Mar/2011 Y.
C B A 100-230VAC 1φ,50/60Hz USB CABLE,MAX.5m *1 COAX. CABLE (75Ω) *2 3COX-2P-6C,5/10m,φ8.5 *1 DPYC-1.5 NOTE *1: SHIPYARD SUPPLY. *2: OPTION. *3: CABLE ASSY. INCLUDED IN MATERIAL FOR EC-1000C.