Operator's Manual
8. INSTALLATION
8-7
Mounting procedure
"Bird-repellent fixtures" (option) can be attached to the sensor cover to prevent birds
from alighting on the cover. If it is more convenient to attach the fixtures before mount-
ing the sensor, do step 8 first.
Note: The mounting procedure differs according to the specification of the antenna
unit.
• For GS-1001-A: Follow steps 1, 2, and 5 to 9.
• For GS-1001-N: Follow steps 1 to 9.
1. As shown in the figure below, weld a platform (local supply) for which to mount the
sensor. The thickness of the platform should be max. 15 mm.
2. Connect the sensor cables.
3. Open the cable cover on the bottom of the sensor.
4. Slip the rubber bushing (supplied) onto the sensor cable at the location shown be-
low. Attach the cable to the connector.
BOW
200
300
160
Flat washer
Max. 15 mm
Spring washer
Hexagonal nut (M10 SUS316L)
Fixing hole (ø11 mm)
160
Cable cover
Air vents
DO NOT fill them.
Cable clamp
Rubber bushing
Projection (This end
of bushing next to
connector.)