Dimensional Drawings

6-ø4.5
342 13.5"
217 8.5"
140 5.5"
4.5
0.2"
335 13.2"
209 8.2"
142 5.6"
49 1.9"
38 1.5"
360 14.2"
235 9.3"
29 1.1"
70
2.8"
383 15.1"
360 14.2"
180 7.1"
191 7.5"
281 11.1"
262 10.3"
235 9.3"
32 1.2"
30
1.2"
20˚
10.4"COLOR LCD RADAR/CHART PLOTTER BLACKBOX RADAR/CHART PLOTTER
MODEL 1934C/BB MODEL 1944C/BB MODEL 1954C/BB MODEL 1964C/-B
ANTENNA
Type Open Open Open
Length 1035 mm
(3.5 ft)
1255 mm
(4 ft)
1255/1795 mm
(4/6 ft)
Beamwidth Hor: 2.2˚
Ver: 22˚
Hor: 1.9˚
Ver: 22˚
Hor: 1.9˚ / 1.2˚
Ver: 22˚
Rotation Speed 24rpm 24/48* rpm
BB 24/48* rpm
(Not Available in 6 ft antenna)
RF TRANSCEIVER
Frequency 9410±30 MHz
(X-Band)
Pulselength & PRR 0.08µs/2100 Hz
(0.125 to 1.5 nm)
0.3µs/1200 Hz
(1.5 to 3 nm)
0.8µs/600 Hz
(3 to 64 nm)
0.08µs/2100 Hz
(0.125 to 1.5 nm)
0.3µs/1200 Hz
(1.5 to 3 nm)
0.8µs/500 Hz
(3 to 96 nm)
Output Power 4 kW 6 kW 12 kW 25 kW
DISPLAY
Display Unit 10.4" Color TFT LCD/Multi-sync monitor required for BlackBox system
Effective Display Area 211.2 (W) x 158.4 (H) mm
(For BlackBox system, please refer to the specifications for the multi-sync monitor)
Pixel Number 640 x 480
(For BlackBox system, please refer to the specifications for the multi-sync monitor)
Range Scales 0.125 to 48 nm
16 steps
0.125 to 64 nm
17 steps
0.125 to 72 nm
18 steps
Echo Trail Interval: 15 s, 30 s, 1 min, 3 min, 6 min, 15 min, 30 min or Continuous
NavNet Interface Ethernet 10 BASE-T
Interface
(NMEA0183 format)
Input
DBT, DPT, DSC, DSE, GGA, GLL, HDG, HDM, HDT, MTW, MWV, RMA, RMB, RMC, TLL, TTM, VHW, VTG, VWT, VWR, WPL, ZDA, ZTG
Output
AAM, APB, BOD, BWC, BWR, DBT, DPT, GGA, GLL, GTD, HDT, MTW, MWV, RMA, RMB, RMC, TLL, TTM, VHW, VTG, WPL, XTE, ZDA, ZTG
PLOTTER CHARACTERISTICS
Map Scale 0.125 to 2,048 nm
Latitude Limits Between 85˚N and 85˚S
Plot Interval 1 s to 99 min 99 s or 0 to 99.99 nm
Display Modes Course plot, Nav data, Steering display, Highway
Presentation Modes TM/RM North-up, Course-up, Auto Course-up
Memory Capacity
Up to 8,000 points for ship's track and marks, 999 waypoints, 35 quick points, 1 MOB, 200 planned routes (max. 35 waypoints/routes), 1 quick route
Alarms Guard Zone, Arrival/anchor watch, XTE, proximity alert, ship speed, depth*, water temperature**, fish*, grounding***
(*Network fish finder required, **temperature sensor required for water temperature alerm, ***C-Map version only)
Electronic Charts* C-Map NT MAX, Navionics GOLD
*Specify when placing a purchase order.
ENVIRONMENT
(IEC 60945 test method)
Temperature
Display Unit
-15˚C to +55˚C
Antenna Unit
-25˚C to +70˚C
Waterproofing
Display Unit
IPX5, CFR-46 (USCG)
Antenna Unit
IPX6
POWER SUPPLY
12-24 VDC
110 W 115 W
125/150
(24/48 rpm,4 ft)
, 130W
(6 ft)
138/152
(24/48 rom, 4 ft)
, 163W
(6 ft)
BB 80/100 W
(24/48 rpm)
85/115 W
(24/48 rpm)
100/120
(24/48 rpm,4 ft)
, 100W
(6 ft)
107/122
(24/48 rpm, 4 ft)
, 132W
(6 ft)
115/230 VAC with an optional rectifier RU-3423/1746B-2
Power Amp Unit
----
PSU-005 PSU-008
OPTIONAL UNIT
Antenna Bracket Locally arranged
10-Target Autoplotter ARP11*
(*Requires an appropreate heading sensor)
External Buzzer OP03-136 or Relay/Contact Closure
NTSC/PAL Interface Kit OP-03-175
(Standard supply for a BlackBox system)
Memory Card Interface CU-300 (For Black Box system only)
10.4" LCD (Bracket Mount) 6.0 kg 13.2 lb 10.4" LCD (Flush Mount) 5.2 kg 11.5 lb
Specications 77
Specications
6-ø4.5
342 13.5"
217 8.5"
140 5.5"
4.5
0.2"
335 13.2"
209 8.2"
142 5.6"
49 1.9"
38 1.5"
360 14.2"
235 9.3"
29 1.1"
70
2.8"
383 15.1"
360 14.2"
180 7. 1"
191 7. 5"
281 11.1"
262 10.3"
235 9.3"
32 1.2"
30
1.2"
20˚
10.4"COLOR LCD RADAR/CHART PLOTTER BLACKBOX RADAR/CHART PLOTTER
MODEL 1934C/BB MODEL 1944C/BB MODEL 1954C/BB MODEL 1964C/-B
ANTENNA
Type Open Open Open
Length 1035 mm
(3.5 ft)
1255 mm
(4 ft)
1255/1795 mm
(4/6 ft)
Beamwidth Hor: 2.2˚
Ver: 22˚
Hor: 1.9˚
Ver: 22˚
Hor: 1.9˚ / 1.2˚
Ver: 22˚
Rotation Speed 24rpm 24/48* rpm
BB 24/48* rpm
(Not Available in 6 ft antenna)
RF TRANSCEIVER
Frequency 9410±30 MHz
(X-Band)
Pulselength & PRR 0.08µs/2100 Hz
(0.125 to 1.5 nm)
0.3µs/1200 Hz
(1.5 to 3 nm)
0.8µs/600 Hz
(3 to 64 nm)
0.08µs/2100 Hz
(0.125 to 1.5 nm)
0.3µs/1200 Hz
(1.5 to 3 nm)
0.8µs/500 Hz
(3 to 96 nm)
Output Power 4 kW 6 kW 12 kW 25 kW
DISPLAY
Display Unit 10.4" Color TFT LCD/Multi-sync monitor required for BlackBox system
Effective Display Area 211.2 (W) x 158.4 (H) mm
(For BlackBox system, please refer to the specifications for the multi-sync monitor)
Pixel Number 640 x 480
(For BlackBox system, please refer to the specifications for the multi-sync monitor)
Range Scales 0.125 to 48 nm
16 steps
0.125 to 64 nm
17 steps
0.125 to 72 nm
18 steps
Echo Trail Interval: 15 s, 30 s, 1 min, 3 min, 6 min, 15 min, 30 min or Continuous
NavNet Interface Ethernet 10 BASE-T
Interface
(NMEA0183 format)
Input
DBT, DPT, DSC, DSE, GGA, GLL, HDG, HDM, HDT, MTW, MWV, RMA, RMB, RMC, TLL, TTM, VHW, VTG, VWT, VWR, WPL, ZDA, ZTG
Output
AAM, APB, BOD, BWC, BWR, DBT, DPT, GGA, GLL, GTD, HDT, MTW, MWV, RMA, RMB, RMC, TLL, TTM, VHW, VTG, WPL, XTE, ZDA, ZTG
PLOTTER CHARACTERISTICS
Map Scale 0.125 to 2,048 nm
Latitude Limits Between 85˚N and 85˚S
Plot Interval 1 s to 99 min 99 s or 0 to 99.99 nm
Display Modes Course plot, Nav data, Steering display, Highway
Presentation Modes TM/RM North-up, Course-up, Auto Course-up
Memory Capacity
Up to 8,000 points for ship's track and marks, 999 waypoints, 35 quick points, 1 MOB, 200 planned routes (max. 35 waypoints/routes), 1 quick route
Alarms Guard Zone, Arrival/anchor watch, XTE, proximity alert, ship speed, depth*, water temperature**, fish*, grounding***
(*Network fish finder required, **temperature sensor required for water temperature alerm, ***C-Map version only)
Electronic Charts* C-Map NT MAX, Navionics GOLD
*Specify when placing a purchase order.
ENVIRONMENT
(IEC 60945 test method)
Temperature
Display Unit
-15˚C to +55˚C
Antenna Unit
-25˚C to +70˚C
Waterproofing
Display Unit
IPX5, CFR-46 (USCG)
Antenna Unit
IPX6
POWER SUPPLY
12-24 VDC
110 W 115 W
125/150
(24/48 rpm,4 ft)
, 130W
(6 ft)
138/152
(24/48 rom, 4 ft)
, 163W
(6 ft)
BB 80/100 W
(24/48 rpm)
85/115 W
(24/48 rpm)
100/120
(24/48 rpm,4 ft)
, 100W
(6 ft)
107/122
(24/48 rpm, 4 ft)
, 132W
(6 ft)
115/230 VAC with an optional rectifier RU-3423/1746B-2
Power Amp Unit
----
PSU-005 PSU-008
OPTIONAL UNIT
Antenna Bracket Locally arranged
10-Target Autoplotter ARP11*
(*Requires an appropreate heading sensor)
External Buzzer OP03-136 or Relay/Contact Closure
NTSC/PAL Interface Kit OP-03-175
(Standard supply for a BlackBox system)
Memory Card Interface CU-300 (For Black Box system only)
10.4" LCD (Bracket Mount) 6.0 kg 13.2 lb 10.4" LCD (Flush Mount) 5.2 kg 11.5 lb
Specications 77
Specications
NavNet vx2 10.4" LCD Display
Dimensional Drawings