Back INSTALLATION MANUAL GPS NAVIGATOR GP-90 1. EQUIPMENT LIST ............................................................................................ 1 2. DISPLAY UNIT .................................................................................................. 2 3. ANTENNA UNIT ................................................................................................ 3 4. WIRING .............................................................................................................
SAFETY INSTRUCTIONS WARNING Do not work inside the equipment unless totally familiar with electrical circuits. Hazardous voltage which can cause electrical shock, burn or serious injury exists inside the equipment. Turn off the power at the mains switchboard before beginning the installation. Post a sign near the switch to indicate it should not be turned on while the equipment is being installed.
1. EQUIPMENT LIST Standards Name Antenna Unit Display Unit Installation Materials Spare Parts Type GPA-017S GPA-018S GPA-019S GP-90-N GP-90-A CP20-01900 CP20-01950 SP20-00500 Q'ty Mass (kg) 1 1 1 set Remarks For DGPS 2.2 Without Beacon RX With Beacon RX See lists at end of With Antenna Cable manual. Without Antenna Cable 1 set Options Name Flush Mount Kit S Flush Mount Kit F Antenna Cable Set Antenna Cable Assy.
2. DISPLAY UNIT The display unit can be installed with either of four methods as shown below. Refer to the outline drawing at the end of manual. • • • • Locate the unit away from exhaust pipes and vents. The mounting location should be well ventilated. Mount the unit where shock and vibration are minimal. Keep the display unit away electromagnetic field generating equipment such as motor, generator. • Allow sufficient maintenance space and a sufficient slack in cables for maintenance and repair.
3. ANTENNA UNIT Mounting Install the antenna unit referring to the installation diagram at end of manual. When selecting a mounting location for the antenna unit, keep in mind the following points. • Select a location out of the radar beam. The radar beam will obstruct or prevent reception of the GPS satellite signal. • Be sure the location offers a clean line-of-sight to satellite.
3. ANTENNA UNIT How to attach the N-P-8DFB connector Outer Sheath Armor Inner Sheath Shield 50 Remove outer sheath and armor by the dimensions shown left. Expose inner sheath and shield by the dimensions shown left. 30 Cover with heat-shrink tubing and heat. Cut off insulator and core by 10mm. 10 30 Twist shield end. Clip on clamp nut, gasket and clamp as shown left. Clamp Nut Gasket Clamp (reddish brown) Aluminum Foil Fold back shield over clamp and trim. Trim shield here.
4. WIRING The figure below shows the connection of cables on rear of display unit. CAUTION Ground the display unit to prevent loss of sensitivity and mutual interference.
4. WIRING Grounding The display unit contains several CPUs. While they are operating, they radiate noise, which can interfere with other radio equipment. Ground the unit as follows to prevent it. • The grounding wire should be 1.25sq or larger. • The grounding wire should be as short as possible. External Equipment The DATA1, DATA2, and DATA3 ports are used to connect an external equipment such as autopilot, remote display, navigation equipment.
5. INITIAL SETTINGS Checking Operation 1. Turn on the GP-90. 2. Confirm that "OK" and "BEACON RCVR INSTALLED" are displayed on the self-test display. PROGRAM MEMORY SRAM Internal Battery =OK =OK =OK BEACON RCVR INSTALLED DATA 3: DATA OUTPUT Confirm that "BEACON RCVR INSTALLED" is displayed when DGPS function is provided. Self-test display at equipment start up 3. Press [MENU ESC], [8] and [1]. Confirm that "BEACON OK" is displayed. DGPS Setup The default setting is "manual".
5. INITIAL SETTINGS 5. Press the [NU/CU ENT] key. 6. Press the [MENU ESC] key. Manual DGPS setup Enter four digit ID number, frequency and baud rate of station. 1. 2. 3. 4. 5. Press [MENU ESC], [9] and [7] to display the DGPS SETUP menu. Press S or T to select DGPS MODE and press W to select “INT BEACON”. Press S or T to select DGPS Station. Press W to select Man. Enter four digit ID number. You can clear an entry by the [CLEAR] key. If there is no ID number, press the [NU/CU ENT] key. 6.
5. INITIAL SETTINGS Input/Output Setting The GP-90 can output navigation information to external equipment. For example, it can output position data to a radar or echo sounder for display on their display screen. You can convert a Loran Plotter to a GPS Plotter with position data from the GP-90. Before selecting data to output, confirm what data the external equipment requires. Output necessary data only. Outputting unnecessary data can cause receiving problems at the external equipment.
5. INITIAL SETTINGS Data format and data output availability Output data sentence of IEC 61162-1 and NMEA 0183 Ver. 1.5/2.0.
5. INITIAL SETTINGS Input data sentence of NMEA 0183 Ver. 1.5/2.0 Checksum is checked if attached, and if any errors are found, the sentence becomes invalid. Talker ID is not distinguished. DBT: Depth below transducer DPT: Depth HDG: Heading, deviation and variation HDM: Heading, magnetic HDT: Heading, true MTW: Water temperature TLL: Target latitude and longitude VBW: Dual ground/water speed VHW: Water speed and heading.
5. INITIAL SETTINGS AGFPA: Autopilot information from FURUNO autopilot equipments Port DATA1 DATA2 DATA3 DATA4 Input NMEA 0183 Ver. 1.5 /2.0 AGFPA , DBT, DPT, HDG, HDM, HDT, MTW, TLL, VBW, VHW External MOB DGPS or general data (Selected by menu) Output IEC 61162-1/NMEA 0183 Ver.1.5/ Ver.2.0 AAM, APA, APB, BOD, BWC, BWR, BWW, GGA, GLL, GNS, RMB, RMC, VDR, VTG, WCV, WPL, XTE, ZDA, GBS, Rnn, RTE LOG PULSE Same as the data output form “DATA1” General data IEC 61162-1/NMEA 0183 Ver.1.5/ Ver.2.
5. INITIAL SETTINGS DATA 1 output setting 1) Press [MENU], [9] and [3]. The DATA 1, 3 OUTPUT SETUP menu appears. DATA 1, 3 OUTPUT SETUP Data Fmt. Talker ID Output Data V1.5 GP (00-90 sec) V2.0 IEC LC DE 100% 1. AAM:00 APA:00 APB:04 BOD:00 2. BWC:00 BWW:00 GGA:00 GLL:01 3. RMB:01 RMC:00 VTG:01 4. VDR:00 WPL:00 XTE:00 5. GNS:00 GBS:01 Rnn:00 200ppm DATA3. Log Pulse ENT : Enter WCV:00 ZDA:01 RTE:00 400ppm MENU : Escape Settings shown here are default settings.
5. INITIAL SETTINGS DATA 2 output setting 1) Press [MENU], [9] and [4]. The DATA 2 OUTPUT SETUP menu appears. DATA2 OUTPUT SETUP V1.5 Data Fmt. Talker ID GP Output Data (00-90 sec) 1. AAM:00 APA:00 2. BWR:00 BWW:00 3. RMB:01 RMC:00 4. VDR:00 WPL:00 5. GNS:00 GBS:01 ENT : Enter V2.0 IEC LC DE 100% APB:04 BOD:00 GGA:00 GLL:01 VTG:01 WCV:00 XTE:00 ZDA:01 Rnn:00 RTE:00 : Select MENU : Escape Setting shown here are default settings.
5. INITIAL SETTINGS Setting DATA 4 to Data Output 1) Press [MENU], [9] and [5]. The DATA 4 I/O SETUP menu appears. DATA 4 I/O SETUP DATA 4. Level Data To Next Page ENT : Enter 1/2 RS232C Out RS422 Com. DGPS : Select MENU : Escape Appears only when external DGPS receiver is used. Figure 5-5 DATA 4 I/O SETUP menu 2) 3) 4) 5) 6) Press S or T to select DATA4. Level. Press W or X to select level of external equipment; RS232C or RS422. Press the [ENT] key. Press W or X to select Out.
5. INITIAL SETTINGS Setting DATA 4 to “COM.” (general data) Waypoints and Routes data can be received from a personal computer, through the DATA 4 port. 1) Press [MENU], [9] and [5]. 2) Press ! or " to select DATA4. Level. 3) Press # or $ to select level of personal computer; RS232C or RS422. 4) Press the [ENT] key. 5) Press $ to select Com. 6) Press " to select To Next Page. The DATA 4 I/O SETUP menu appears. DATA 4 I/O SETUP
5. INITIAL SETTINGS 14) Output data from the computer. When loading data is completed, the cursor shifts to Stop. 15) Press the [ESC] key. Setting DATA 4 to DGPS An external DGPS receiver can be connected to the DATA 4 port. Follow the procedure below to setup the GP-90 according to the specifications of the DGPS receiver. 1) Press [MENU], [9] and [5]. 2) Press ! or " to select Level. 3) Press # or $ to select level; RS232C or RS422. 4) Press the [ENT] key. 5) Press # or $ to select DGPS.
6. OPTIONAL DGPS Beacon Receiver Set GR-80 GP-90 GR-80 DATA4 RS-422* TD-A TD-B RD-A RD-B NP Board JP3 GND Open Whip Antenna DATA 1 2 3 4 5 6 7 WHT BLK YEL GRN BLU P P 4 3 2 1 7 RD-A RD-B TD-A TD-B GND RS-422 Preamp unit (with 15 m cable) * This connection is required for L/L Auto mode of GR-80. When the GP-90 is connected with Beacon Receiver GR-80, do the setting as follows.
7. TAPING ANTENNA UNIT GPA-018S After inserting the whip antenna to the antenna base of GPA-018S, tape the antenna base and whip antenna with self-vulcanizing tape and vinyl tape to reinforce the whip antenna. 1. Wrap the antenna junction point with butyl 15 tape or the equivalent. How to wrap 1) Pull the tape to be about two times in length and wind it up, overlapping by 1/2 the width of the tape. 2) Wrap from bottom to top, i.e., from right to left as in the picture below.
NAME OUTLINE 000-802-081 5X20 SUS304 100-183-262 100-183-271 20-007-3011-2 20-007-3012-1 4 1 1 CP20-01111 (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) 2.(*1)の空中線部は仕様により決定されます。 ANTENNA UNIT HAS BEEN DETERMINED BY SPECIFICATION. 3 CP20-01101 FGBO-A 2A AC125V 000-549-062 (*1) 1 (*1) 1 (*1) 1 1 Q'TY DOCUMENT 3.(*2)のアンテナケーブル組品は、有り・無しの仕様が有ります。 AVAILABLE WITH OR WITHOUT ANTENNA UNIT.
NAME OUTLINE OTHER INSTALLATION MATERIALS INSTALLATION MATERIALS SPARE PARTS UNIT 000-158-000 000-133-670 MJ-A2SPF0014030C TNC-PS-3D15 20S0216 000-802-081 5X20 SUS304 (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) 2.(*1)の空中線部は仕様により決定されます。 ANTENNA UNIT HAS BEEN DETERMINED BY SPECIFICATION. 3 1 (*2) 1 4 CP20-01101 FGBO-A 2A AC125V 000-549-062 (*1) 1 (*1) 1 (*1) 1 1 Q'TY DOCUMENT OUTLINE 3.(*2)のアンテナケーブル組品は、有り・無しの仕様が有ります。 AVAILABLE WITH OR WITHOUT ANTENNA UNIT.
A-3 Antenna Cable Set CP20-01700 (004-372-110) CP20-01710 (004-372-120) CODE NO. 004-372-420-00 TYPE CP20-01701 20AG-X-9405 -4 1/1 工事材料表 INSTALLATION MATERIALS 番 号 NO. 名 称 NAME 型名/規格 DESCRIPTIONS 略 図 OUTLINE 数量 Q'TY 用途/備考 REMARKS 変換ケーブル組品 1 NJ-TP-3DXV-1 CONVERT CABLE ASSY. CODE NO. 2 000-123-809-00 ビニルテープ 2 NO360 0.2X19X10000 VINYL TAPE CODE NO. 1 000-835-215-00 コネクタ(N) 3 N-P-8DFB-CF CONNECTOR CODE NO. 絶縁テープ 4 SELF-BONDING TAPE Uテープ 000-156-918-10 0.5X19X5M Uテープ 0.
A-4 Antenna Cable Set CP20-02700 (004-381-160) CP20-02710 (004-381-170) CODE NO. 004-381-190-00 TYPE CP20-02701 20AX-X-9401 -5 1/1 工事材料表 INSTALLATION MATERIALS 番 号 NO. 名 称 NAME 型名/規格 DESCRIPTIONS 略 図 OUTLINE 数量 Q'TY 用途/備考 REMARKS 変換ケーブル組品 1 NJ-TP-3DXV-1 CONVERT CABLE ASSY. CODE NO. 1 000-123-809-00 ビニルテープ 2 NO360 0.2X19X10000 VINYL TAPE CODE NO. 1 000-835-215-00 コネクタ(N) 3 N-P-8DFB-CF CONNECTOR CODE NO. 1 000-156-918-10 コネクタ 4 TNCP-NJ CONNECTOR CODE NO.
Apr.
Apr.
Apr.
Y. Hatai hatai 2005.12.
D-5 Sep.
D-6 Feb.
D-7 Feb.
D-8
C B A 2 *3 TNC-P-3 56 12 (-) 整流器 (+) RECTIFIER PR-62 *2 DPYC-1.5 *1 NMEA0183 V1.5 J12 1 ANT 2 GND GPS ANT INPUT *3 MJ-A2SPF J1 アカ RED 1 (+) クロ BLK 2 (-) NOTE *1. SHIPYARD SUPPLY *2. OPTION *3. CONNECTOR PLUG FITTED AT FACTORY. *4. SELECTED ON MENU *5. SELECTED BY JUMPER WIRE JP4/JP5 ON NP BOARD (DEFAULT SETTING: IEC61162-1/NMEA0183). 3 DWG NO. SCALE MASS Y. Hatai E.MIYOSHI TAKAHASHI.T C4427-C01- F Apr.17,'06 APPROVED CHECKED DRAWN 1 2 3 4 5 6 7 kg GND *1 IV-1.25sq.
The paper used in this manual is elemental chlorine free. FURUNO Authorized Distributor/Dealer 9-52 Ashihara-cho, Nishinomiya 662-8580, JAPAN Telephone : 0798-65-2111 Fax 0798-65-4200 : All rights reserved. Printed in Japan FIRST EDITION :AUG. : AUG. 2003 C1 Pub. No. IME-44270-C1 ( HIMA ) GP-90 : APR.