326 EC-3000 Ch.07
COM Timeout
Caution
Input from EC-3000 serial
ch.7 has been discontinued
for more than certain time.
(Set at installation)
Default: No timeout
Check the connection of
Ch.7.
327 EC-3000 Ch.08
COM Timeout
Caution
Input from EC-3000 serial
ch.8 has been discontinued
for more than certain time.
(Set at installation)
Default: No timeout
Check the connection of
Ch.8.
330 Double Gyro Sta-
tus Conflict
Warning
When connected with
Double Gyro System,
instrument produced by
Yokogawa Electric, two
gyro has been displayed
"Selected" status for 3
seconds.
If the error frequently
occurs, contact FURUNO
and inform frequency of
occurrence.
331 Select Gyro Status
Missing
Warning
When connected with
Double Gyro System,
instrument produced by
Yokogawa Electric, "Double
Gyro" status cannot be
acquired.
If the error frequently
occurs, contact FURUNO
and inform frequency of
occurrence.
360 Wind Sensor 1
COM Error
Caution
Data from No.1 wind sensor
has been discontinued for
more than set time.
(Set at installation)
Default: 60 seconds
No.1 wind sensor is turned
off, or there is a problem
with network.
Check the connection with
No.1 wind sensor.
361 Wind Sensor 2
COM Error
Caution
Data from No.2 wind sensor
has been discontinued for
more than set time.
(Set at installation)
Default: 60 seconds
No.2 wind sensor is turned
off, or there is a problem
with network.
Check the connection with
No.2 wind sensor.
362 Wind Sensor 3
COM Error
Caution
Data from No.3 wind sensor
has been discontinued for
more than set time.
(Set at installation)
Default: 60 seconds
No.3 wind sensor is turned
off, or there is a problem
with network.
Check the connection with
No.3 wind sensor.
No. Text Default Meaning Remedy