Operator's Manual
APPENDIX 5 ALERT LIST
AP-45
303 HCS 1 COM Error Caution
Data from No.1 HCS has
been discontinued for more
than set time.
(Set at installation) Default:
60 seconds
No.1 HCS is turned off, or
there is a problem with
network.
Check the connection with
No.1 HCS and network.
304 HCS 2 COM Error Caution
Data from No.2 HCS has
been discontinued for more
than set time.
(Set at installation) Default:
60 seconds
No.2 HCS is turned off, or
there is a problem with
network.
Check the connection with
No.2 HCS and network.
305 VDR COM Error Caution
Sentence from VDR has
been discontinued for more
than set time.
(Set at installation)
Default: 180 seconds
VDR is turned off, or there
is a problem with network.
Check the connection with
VDR and network.
306 BNWAS COM Er-
ror
Caution
Caution Sentence from
BNWAS has been
discontinued for more than
set time. (Set at installation)
Default: 180 seconds
BNWAS is turned off, or
there is a problem with
network.
Check the connection with
BNWAS and network.
310 Other Sensor 1
COM Error
Caution
Data from No.1 other
sensor has been
discontinued for more than
set time.(Set at installation)
Default: 180 seconds
No.1 other sensor is turned
off, or there is a problem
with network.
Check the connection with
No.1 other sensor and
network.
311 Other Sensor 2
COM Error
Caution
Data from No.2 other
sensor has been
discontinued for more than
set time. (Set at installation)
Default: 180 seconds
No.2 other sensor is turned
off, or there is a problem
with network.
Check the connection with
No.2 other sensor and
network.
No. Text Default Meaning Remedy