APPENDIX 5 ALERT LIST
AP-40
172 Off Track Alarm Alarm
Deviation is big between
planning course and
current heading. While
monitoring route, ship
position deviates Channel
Limit.
Reconfirm Channel Limit or
keep own ship inside of
channel limit.
235 Echo Sounder 1
COM Error
Caution
Input of depth data from
No.1 echo sounder has
been discontinued for more
than set time.
(Set at installation)
Default: 60 seconds
No.1 echo sounder is
turned off, or there is a
problem with network.
Check the connection with
No.1 echo sounder and
network.
236 Echo Sounder 2
COM Error
Caution
Input of depth data from
No.2 echo sounder has
been discontinued for more
than set time.
(Set at installation)
Default: 60 seconds
No.2 echo sounder is
turned off, or there is a
problem with network.
Check the connection with
No.2 echo sounder and
network.
237 Echo Sounder 3
COM Error
Caution
Input of depth data from
No.3 echo sounder has
been discontinued for more
than set time.
(Set at installation)
Default: 60 seconds
No.3 echo sounder is
turned off, or there is a
problem with network.
Check the connection with
No.3 echo sounder and
network.
255 Gyro 1 COM Error Caution
Data from No.1 gyro has
been discontinued for more
than set time.
(Set at installation)
Default: 60 seconds
No.1 gyro is turned off, or
there is a problem with
network.
Check the connection with
No.1 gyro and network.
256 Gyro 2 COM Error Caution
Data from No.2 gyro has
been discontinued for more
than set time.
(Set at installation)
Default: 60 seconds
No.2 gyro is turned off, or
there is a problem with
network.
Check the connection with
No.2 gyro and network.
No. Text Default Meaning Remedy