Operator's Manual
APPENDIX 5 ALERT LIST
AP-37
074 EC-3000 GPU
Temp High
Caution
CPU temperature in
processor unit exceeds
threshold.
Turn off Processor Unit. If
same error occurs after a
few minutes, contact
FURUNO.
075 EC-3000 CPU
Board Temp High
Caution
CPU temperature in
processor unit exceeds
threshold.
Turn off Processor Unit. If
same error occurs after a
few minutes, contact
FURUNO.
076 EC-3000 Remote 1
Temp High
Caution
CPU temperature in
processor unit exceeds
threshold.
Turn off Processor Unit. If
same error occurs after a
few minutes, contact
FURUNO.
077 EC-3000 Remote 2
Temp High
Caution
CPU temperature in
processor unit exceeds
threshold.
Turn off Processor Unit. If
same error occurs after a
few minutes, contact
FURUNO.
078 EC-3000 CPU Fan
Rotation Speed
Lowering
Caution
Rotation speed of CPU fan
in processor unit is below
threshold.
If the error frequently
occurs, contact FURUNO
and inform frequency of
occurrence.
079 EC-3000 Fan1
Rotation Speed
Lowering
Caution
Rotation speed of fan1 in
processor unit is below
threshold.
If the error frequently
occurs, contact FURUNO
and inform frequency of
occurrence.
080 EC-3000 Fan2
Rotation Speed
Lowering
Caution
Rotation speed of fan2 in
processor unit is below
threshold.
If the error frequently
occurs, contact FURUNO
and inform frequency of
occurrence.
082 EC-3000 CPU
Fan No Rotation
Warning
Rotation speed of fan in
processor unit is below
threshold.
If the error frequently
occurs, contact FURUNO
and inform frequency of
occurrence.
083 EC-3000 CPU
Fan1 No Rotation
Warning
Rotation speed of fan1 in
processor unit is below
threshold.
If the error frequently
occurs, contact FURUNO
and inform frequency of
occurrence.
084 EC-3000 CPU
Fan2 No Rotation
Warning
Rotation speed of fan2 in
processor unit is below
threshold.
If the error frequently
occurs, contact FURUNO
and inform frequency of
occurrence.
086 EC-3000 CPU
board 5V Power
Error
Warning
5 V power voltage of CPU
board in processor unit is
out of threshold.
If the error frequently
occurs, contact FURUNO
and inform frequency of
occurrence.
087 EC-3000 CPU
board 3.3V Power
Error
Warning
3.3 V power voltage of CPU
board in processor unit is
out of threshold.
If the error frequently
occurs, contact FURUNO
and inform frequency of
occurrence.
088 EC-3000 CPU
board 12V Power
Error
Warning
12 V power voltage of CPU
board in processor unit is
out of threshold.
If the error frequently
occurs, contact FURUNO
and inform frequency of
occurrence.
No. Text Default Meaning Remedy