Operator's Manual

APPENDIX 5 ALERT LIST
AP-35
022 Fan3 No
Rotation
Warning For MU-231: Connected to
COM2 (Sub Monitor).
Fan3 rotation speed is be-
low threshold.
If the error frequently
occurs, contact FURUNO
and inform frequency of
occurrence.
023 Fan4 No
Rotation
Warning For MU-190: Connected to
COM2 (Sub Monitor).
Fan4 rotation speed is be-
low threshold.
If the error frequently
occurs, contact FURUNO
and inform frequency of
occurrence..
024 RS485 Communi-
cation Timeout
Caution For MU-190/231: Connect-
ed to COM2. There has
been no communication
from processor unit through
RS485 for 180 seconds.
(No communication implies
incomplete sentence or
checksum error.)
Check the connection of
brightness control cable.
025 No Signal Caution For MU-190/231: Connect-
ed to COM2. There has
been no signal continuously
for 60 seconds.
Check the connection of
video cable.
026 Sentence Syntax
Error
Caution For Sub monitor, connected
to COM2, value of external-
ly input sentence is out of
range defined by sentence.
If the error frequently
occurs, contact FURUNO
and inform frequency of
occurrence.
027 Main Monitor COM
Timeout
Caution Communication with MU is
interrupted. 60 seconds tim-
eout.
Check the connection with
the monitor.
028 Sub Monitor
COM Timeout
Caution Communication with MU is
interrupted. 60 seconds tim-
eout.
Check the connection with
the monitor.
030 Sensor Adapter 1
COM Timeout
Caution Communication error with
No.1 sensor adapter is de-
tected. 30 seconds timeout.
No.1 sensor adapter is
turned off, or there is a prob-
lem with network.
Check the connection with
No.1 sensor adapter and
network.
031 Sensor Adapter 2
COM Timeout
Caution Communication error with
No.2 sensor adapter is de-
tected. 30 seconds timeout.
No.2 sensor adapter is
turned off, or there is a prob-
lem with network.
Check the connection with
No.2 sensor adapter and
network.
032 Sensor Adapter 3
COM Timeout
Caution Communication error with
No.3 sensor adapter is de-
tected. 30 seconds timeout.
No.3 sensor adapter is
turned off, or there is a prob-
lem with network.
Check the connection with
No.3 sensor adapter and
network.
033 Sensor Adapter 4
COM Timeout
Caution Communication error with
No.4 sensor adapter is de-
tected. 30 seconds timeout.
No.4 sensor adapter is
turned off, or there is a prob-
lem with network.
Check the connection with
No.4 sensor adapter and
network.
No. Text Default Meaning Remedy