Operator's Manual

24. MAINTENANCE AND TROUBLESHOOTING
24-5
24.6 Consumable Parts
The table below lists the consumable parts in the Processor Unit, Sensor Adapters
and Monitor Units. Replace the parts before their expected expirations.
route monitoring is
stopped
Alert 691: RM Stop - Exceed Max
XTE. Own ship is too far away
from the route.
Alert 692: No Valid Sensor Data.
ECDIS internal error.
Alert 693: RM Stop - Other
Causes. Required data (position,
SOG/COG) not found.
Steer the ship back to the route
then restart route monitoring.
• Request service.
Check sensor connections.
user chart is not dis-
played on radar
overlay
user chart is not selected in Voy-
age navigation mode.
Select user chart in Voyage navi-
gation mode.
message "Nearing
memory usage limit.
Click the Restart
button to restart the
system to prevent
trouble."
appears
the memory usage limit for soft-
ware is close to capacity. Perfor-
mance may be affected.
If you need to save your work, click
the [Later] button then reset the
power. If you don’t need to save
your work, click the [Restart] but-
ton.
Note that the notice does not ap-
pear in the Conning mode.
message "Nearing
memory usage limit.
If you will start moni-
toring, click the Re-
start button to restart
the system to pre-
vent trouble during
route monitoring."
the memory usage limit for soft-
ware is close to capacity. Perfor-
mance may be affected.
Click the [Restart] button.
message "Memory
usage limit reached.
Click the Restart
button to restart the
system to prevent
trouble."
appears.
the memory usage limit for soft-
ware is reached. Performance
may be affected.
Click the [Restart] button to reset
the power. No other operations are
available other than restart.
Note that the notice does not ap-
pear in the Conning mode.
both the operating
mode buttons [EC-
DIS] and [CON-
NING] are yellow
the memory usage limit for soft-
ware is close to capacity. Perfor-
mance may be affected.
Stop all operations and reset the
power.
Unit Part Type Life
Processor Unit
EC-3000
CPU Fan 109R0612G429 8.5 years
Power Fan 109P0612H761 8.5 years
Chassis Fan 109P0612H761 8.5 years
Sensor Adapter
MC-3000S
MC-CS Board 24P0114 8.5 years
Sensor Adapter
MC-3010A
MC-ANLG Board 24P0115 7.0 years
Monitor Unit MU-190 BEZEL (19) & LCD ASSEMBLY 50,000 hours
MU-231 BEZEL (23) & LCD ASSEMBLY 50,000 hours
If… then… Remedy