IMPORTANT NOTICES • The descriptions in this manual are intended for readers with a solid knowledge of English. • No part of this manual may be copied or reproduced without written permission. • If this manual is lost or worn, contact your dealer about replacement. • The contents of this manual and equipment specifications are subject to change without notice. • The example screens (or illustrations) shown in this manual may not match the screens you see on your display.
SAFETY INSTRUCTIONS SAFETY INSTRUCTIONS The operator of this equipment must read these safety instructions before attempting to operate the equipment. WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.
TABLE OF CONTENTS FOREWORD ............................................................................................... iv SYSTEM CONFIGURATION ..................................................................... vi 1. FI-501 WIND ANGLE, FI-502 CLOSE HAULED WIND ANGLE............. 1 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 Operating Controls ............................................................................................... 1 Turning the Power On/Off .............................................
FOREWORD A Word to the Owner of the FI-501, FI-502, FI-505, FI-506 Congratulations on your choice of the FURUNO FI-501 Wind Angle, FI502 Close Hauled Wind Angle, FI-505 Course Pilot and the FI-506 Rudder, members of the FI-50 series of marine instruments. We are confident you will see why the FURUNO name has become synonymous with quality and reliability. For over 50 years FURUNO Electric Company has enjoyed an enviable reputation for quality marine electronics equipment.
FOREWORD FI-505 The FI-505 Course Pilot displays heading and course information, and its main features are • Heading and average heading • Locked heading • Course made good • Adjustments for • • • • Heading response Pointer response Course made good response Pointer alignment FI-506 The FI-506 Rudder displays rudder angle, and its main features are • Analog rudder indication • Alignment with keypads v
SYSTEM CONFIGURATION Standalone configuration FI-5001 WIND TRANSDUCER TERMINAL BOX (where necessary) FI-502 FI-501 OR : Standard Supply : Optional Supply : Local Supply 12 VDC FI-501/FI-502 HEADING SENSOR AUTOPILOT 30 12 VDC 12 VDC FI-505 FI-506 NOTICE: Turn on the terminal resistor in the instrument when connecting an NMEA 2000 sensor. For the procedure, see installation chapter.
SYSTEM CONFIGURATION NMEA 2000 network FI-5001 WIND TRANSDUCER TERMINAL BOX (where necessary) FI-503 DIGITAL FI-501 Wind Angle/ FI-502 Close Hauled Wind Angle FI-504 MULTI 30 FI-505 COURSE PILOT NMEA 2000 SENSOR* NMEA 2000 SENSOR* NMEA 2000 SENSOR* FI-506 RUDDER NMEA 2000 SENSOR* NMEA 2000 SENSOR* JUNCTION BOX FI-5002 * NMEA 2000 SENSORS - Boat speed - Depth - Heading - Navigation - Environment - Autopilot - Engine 12 VDC (not necessary if powered by NMEA 2000 network) : Standard Supply : Opt
SYSTEM CONFIGURATION This page is intentionally left blank.
1. FI-501 WIND ANGLE FI-502 CLOSE HAULED WIND ANGLE The FI-501 Wind Angle and FI-502 Close Hauled Wind Angle instruments provide precise analog wind angle together with digital speed indication, in true or apparent direction. Wind speed is displayed in knots, meters/second or as a Beaufort scale number. In addition to wind direction and speed indications these instruments provide: • Velocity made good (VMG). • Alarms for minimum and maximum true wind speeds, and high and low apparent wind angles. 1.
1. FI-501 WIND ANGLE, FI-502 CLOSE HAULED WIND ANGLE 1.2 Turning the Power On/Off To power the instrument, press the MODE key. All LCD segments go on and off and then the last-used display appears. To power off the instrument, press the MODE and APP/TRUE keys together. The timer appears and counts down from three seconds to one second, and then the power goes off. Press MODE and APP/TRUE keys together 2 3 1 POWER OFF Power OFF sequence 1.3 Adjusting Brilliance and Contrast 1.
1. FI-501 WIND ANGLE, FI-502 CLOSE HAULED WIND ANGLE 1.4 Display Layout The FI-501 Wind Angle and FI-502 Close Hauled Wind Angle instruments provide analog dial and digital wind information. The display shows that information in true or apparent, depending on mode selected. The pointer shows the true or apparent wind direction.
1. FI-501 WIND ANGLE, FI-502 CLOSE HAULED WIND ANGLE 1.5 Selecting a Display Press the MODE key to select a display. Each press of the key changes the display in the sequence shown below. Wind speed 12.5 kt APP Beaufort wind speed MAX F12 13.5 kt TRUE Maximum true wind speed MAX 200° 20.0 MODE LO HI APP kt TRUE Low apparent wind angle alarm Maximum true wind speed alarm 50° 5.
1. FI-501 WIND ANGLE, FI-502 CLOSE HAULED WIND ANGLE Beaufort no. and wind speed Wind speed Beaufort no. 1.6 kt m/s Wind speed Beaufort no. kt m/s 0 0 0-0.2 7 28-33 14.4-17.4 1 1-3 0.5-2.0 8 34-40 17.5-21.0 2 4-6 2.1-3.5 9 41-47 21.1-24.6 3 7-10 3.6-5.6 10 48-55 24.7-28.8 4 11-16 5.7-8.6 11 56-63 28.9-32.6 5 17-21 8.7-11.2 12 64 32.7-32.9 6 22-27 11.3-14.
1. FI-501 WIND ANGLE, FI-502 CLOSE HAULED WIND ANGLE 1.7 Displaying Velocity Made Good (VMG) Information VMG is the actual vessel speed after adjusting for such factors as current and wind. Use the VMG key to display and erase VMG information and current display alternately. (The VMG information cannot be shown when an alarm display is currently shown.). The VMG display requires boat speed information. If no boat speed is available three dashes is shown. SP VMG EE D WIND VMG 3.2 1.
1. FI-501 WIND ANGLE, FI-502 CLOSE HAULED WIND ANGLE 1.9 Alarms There are four conditions which trigger audio and visual alarms: Maximum true wind speed, Low true wind speed, High apparent wind angle, and Low apparent wind angle. 1. Press the MODE key to select desired alarm page, referring to the illustration below. MAX 20.0 TRUE kt Max. true wind speed alarm 5.
1. FI-501 WIND ANGLE, FI-502 CLOSE HAULED WIND ANGLE This page is intentionally left blank.
2. FI-505 COURSE PILOT The FI-505 Course Pilot provides compass heading, in digital format. In the locked mode, steering error to ±30° deviation of locked course heading is shown, with the analog pointer. In the unlocked mode the pointer is set to zero. In the locked mode, the pointer shows course error; that is, the difference between the current heading and the locked course. 2.1 Operating Controls Steering error scale (for locked mode) Pointer 30 Heading (or COG) /CLEAR - Increment value.
2. FI-505 COURSE PILOT 2.2 Turning the Power On/Off To power the instrument, press the MODE key. All LCD segments go on and off and then the last-used display appears. To power off the instrument, press the MODE and ENT keys together. The timer appears and counts down from three seconds to one second, and then the power goes off. Press MODE and ENT keys together 3 2 1 POWER OFF Power OFF sequence 2.3 Adjusting Brilliance and Contrast 1. Press the MODE and ENT keys together.
2. FI-505 COURSE PILOT 2.4 Selecting a Display Press the MODE key to select a display, and the selection changes in the sequence shown below. If no heading data is not available three dashes appear on the digital display. Current heading (or locked heading) 135° MAG Course over ground 125° COG Display 135° AVG MODE 130° Average heading MAG Function Heading, shown in true or magnetic, selectable on the setup1 menu. See the chapter on installation for details. MAG AVG 130° Average heading.
2. FI-505 COURSE PILOT 2.5 Unlocked and Locked Heading Modes In the unlocked mode, the digital display shows the current heading, true or magnetic, and the pointer is at zero. The unit always starts up in the unlocked mode. Unlocked heading In the locked mode, the operator sets a fixed (locked) heading, with the arrow keys. The digital display shows either locked heading or current heading, depending on calibration setting.
3. FI-506 RUDDER The FI-506 Rudder displays rudder angle, in analog indication. The pointer shows the rudder position in real time. The instrument’s scale range is -40° to +40° about zero. The FI-506 operates in real time, thus almost no action is required of the operator other than confirming the rudder angle and adjustment of the brilliance. 3.1 Operating Controls Pointer Scale Move pointer leftward. Move pointer rightward. BRILL Adjust display brilliance. Turn power on/off.
3. FI-506 RUDDER 3.2 Turning the Power On/Off To power the instrument, press the [ ] key. After the pointer moves to current rudder angle, release the key. To power off the instrument, press and hold down the [ ] key until the backlight goes off. 3.3 Adjusting Display Brilliance Use the BRILL key to adjust the display brilliance. There are three levels of brilliance. The brilliance will be the same on all units which are synchronized. (For how to synchronize units, see page 32.) 3.
4. MAINTENANCE, TROUBLESHOOTING This chapter provides the information necessary for keeping your equipment in good working order. WARNING Do not open the equipment. Only qualified personnel should work inside the equipment. 4.1 Preventive Maintenance Following the recommended procedures below will help maintain performance. Check item Cabling Cabinet Check point Remedy Check that all cabling is Reconnect if necessary. Replace if damaged. securely fastened and is free or rust and corrosion.
4. MAINTENANCE, TROUBLESHOOTING 4.2 Troubleshooting If you feel the equipment is not functioning properly, follow the procedures in the table below to try to restore normal operation. If normal operation cannot be restored, do not attempt to check inside the cabinet. There are no user-serviceable parts inside. Troubleshooting Problem Power cannot be turned on Possible cause • Power supply • Cabling disconnected or damaged. Remedy • Check power supply. • Check cabling.
5. INSTALLATION NOTICE Do not apply paint, anti-corrosive sealant or contact spray to coating or plastic parts of the equipment. Those items contain organic solvents that can damage coating and plastic parts, especially plastic connectors. 5.1 Equipment Lists Standard supply for FI-501 WIND ANGLE Name Display Unit Wind Transducer Installation Materials Type FI-501 FI-5001 CP26-00100 Code No. 000-011-739 Qty 1 1 1 set CP26-00201 001-026-600 1 set CP26-00300 000-010-511 Select one.
5. INSTALLATION Standard supply for FI-506 RUDDER Name Display Unit Installation Materials Type FI-506 CP26-00500 Code No. 000-011-742 Qty 1 1 set Remarks See packing list at end of manual for details. Optional supply Name Wind Transducer Terminal Box Cable Assy. Flush Mount Kit Installation Materials Junction Box 18 Type FI-5001 FI-5001-TERMINAL FI-50-DROP FI-50-CHAIN-0.3M FI-50-CHAIN-5M FI-50-CHAIN-1M FI-50-CHAIN-10M FI-50-CHAIN-20M FI-50-FLUSH-KIT CP26-00300 Code No.
5. INSTALLATION 5.2 Mounting 5.2.1 Wind Transducer FI-5001 (for FI-501, FI-502) Installation site Fix the transducer to the mounting mast so that its mounting base is parallel with the water line. Also, position the transducer so its leading edge faces the bow. Mounting procedure 1. Orient the mounting base as shown in the figure below, with the threaded part of the mounting base facing the bow. Fix the mounting base to the mast with four self-tapping screws (supplied). 80 55 ±0.5 50 40 ±0.5 7.
5. INSTALLATION 3. Mate the connector at the rear of the transducer to cable assy. FI-50-SENSOR-30/50 (30 m or 50 m, supplied). Cap Wind Transducer Cable Assy. FI-50-SENSOR-30/50 Mounting Base 4. As shown in the figure below, make a loop in the cable assy. Fix the cable to the mounting base with two cable ties (local supply). Cable Assy. FI-50-SENSOR-30/50 (30 m or 50 m) Cable Tie (local supply) 5. Pass the cable assy. through the mast and connect it to the FI-501/FI502.
5. INSTALLATION 5.2.2 Display unit The display unit can be installed two ways: surface mount (two ways) or flush mount (optional kit required). This section covers surface mounting. For flush mounting, see the flush mounting instructions, issued separately. Surface mount 1: Fix instrument from front panel 1. Using the template at the back of this manual, open a mounting hole in the installation site. 2. Detach the front panel together with the keypad assy. Attach sponge (supplied) to rear of display unit.
5. INSTALLATION Surface mount 2: Fix instrument from rear panel 1. Using the template at the back of this manual, open a mounting hole in the installation site. 2. Insert studs (M3x40, 2 pcs., supplied) in the holes shown below. (Use only the studs supplied.). Insert stud here. 3. Set the display unit to the mounting hole, inserting studs through respective holes. Fix the display unit with wing nuts (M3, supplied).
5. INSTALLATION 5.3 Wiring 5.3.1 Standalone configuration For standalone configuration the junction box is not necessary; connect the instrument directly to the power supply. Wind Transducer FI-5001* Cable Assy. FI-50-SENSOR-30/50 (30 m or 50 m) – Black Display Unit FI-501/502/505/506 + Red 12 VDC FI-50-DROP Cable (6 m) * Omit for FI-505/506. Note: Turn on the display unit’s terminal resistor.
5. INSTALLATION 3. Unfasten two self-tapping screws to remove the cover of the terminal box. 4. Connect the cables to the terminal inside the terminal box, referring to the interconnection diagram. Bind wires with cable ties at the locations shown below. Terminal Cable Tie Cable Tie 2-φ3.5 (Fixing hole) 24 30 5. Fasten the cover with the screws removed at step 4. Use two self-tapping screws (M3×12, supplied) to fix the terminal box.
5. INSTALLATION 5.3.2 NMEA 2000 network configuration Wind Transducer FI-5001 FI-50-CHAIN (0.3 m: Std, 1/5/10/20 m: Option) Cable Assy. FI-50-SENSOR-30/50 (30 m or 50 m) DISP. UNIT FI-503/FI-504/FI-505/FI-506 DISP. UNIT (Instruments can be connected FI-501/FI-502 in any order.
5. INSTALLATION Junction box (option) The junction box is required when connecting NMEA 2000 network. This section covers wiring of the junction box. For how to mount the junction box, see its installation instructions, issued separately. 12VDC CN3 CN4 DROP DROP CN5 DROP BACKBONE 12 VDC FI-501/502/503/504/505/506 NMEA2000 DEVICE Fix cable with cable tie (supplied). CN3 DROP - CN5 DROP and BACKBONE are socket-and-plug-type terminal blocks.
5. INSTALLATION Terminal resistor The illustration below show various system configurations and what units to activate the terminal resistor.
5. INSTALLATION Turn on the terminal resistor in the junction box when the NMEA 2000 sensor(s) connected to it do not have a terminal resistor. Terminal Resistor OFF: ON: For how to turn on the terminal resistor in a FI-50 series instrument, see page 33 (FI-501//FI-502/FI-505) or page 35 (FI-506).
5. INSTALLATION 5.4 Setting Up Your instrument is pre-programmed with factory default settings, which may or may not be suited to your vessel. Therefore, it is necessary to initialize the instrument for use with your vessel. This should be done immediately after completion of the installation. Two sets of setup menus are provided: setup1 and setup2. The setup1 menu provides system parameters and setup2 has user settings.
5. INSTALLATION 3. Use the 3rd and 4th keys to set a value or select option. 3rd key: Decrement value. 4th key: Increment value or select option. 4. To continue, press the MODE key to select another item. 5. To save settings and restore normal operation, press the 3rd and 4th keys together. Setup1 menu items for FI-501, FI-502 Display Function Setting range or options Default setting F Select source of wind data. Select “r” for second unit. F: For FI-5001, r: repeater Select source of wind input.
5. INSTALLATION Setup1 menu items for FI-505 Menu item (in sequential order) Function Select bearing reference. CAL HI Setting range Default or options setting MAG: Magnetic, MAG TRUE: True MAG CAL ALI HI CAL LOC° Align pointer to zero. Operate the W key or the X/CLEAR key until the pointer is at zero. Enables/disables use of locked heading. Choose LOC to enable locked heading. LOC: Locked, Cur: Current LOC LOCK CAL H 0 CAL P 0 CAL C 0 Set heading response.
5. INSTALLATION Setup2 menu The setup2 menu contains items which once preset do not require frequent adjustment. This menu is mostly operated the same as the setup1 menu. The only difference is how long the 3rd and 4th keys are pressed to activate the menu. 1. Press the 3rd and 4th keys together (about 5-6 seconds) until the software version screen for CPU1 appears. (See the illustration below.) 2. Press the MODE key to select a menu item.
5. INSTALLATION Setup2 menu items Display CAL XXx CAL XXx CAL Function Default setting Options Software version of CPU1. XX=program no. and x=program version no. - Software version of CPU2. XX=program no. and x=program version no - Key beep on/off. 1: ON, 0: OFF 1(ON Adjust brilliance automatically with environment. 1: ON, 0: OFF 1(ON) Enable/disable access to the setup1 menu. 1: ON, 0: OFF 1(ON) Terminal resistor on/off.
5. INSTALLATION 5.4.2 Setting up FI-506 Rudder calibration You can apply an offset to the rudder indication to remove any deviation from actual and displayed rudder angles. 1. With the rudder centered, press the W and X keys together until the instrument starts beeping continuously. The beeping indicates you have correctly enabled the calibration mode. 2. Use the W and X keys to move the pointer to the zero position. 3.
FI-501 WIND ANGLE/FI-502 CLOSE HAULED WIND ANGLE SPECIFICATIONS OF FI-501 WIND ANGLE FI-502 CLOSE HAULED WIND ANGLE 1 GENERAL 1.1 Display 1.2 Display Content 1.3 Analog Meter Range 1.4 Analog Meter Accuracy 1.5 I/O Port Analog and segment LCD Wind angle, wind speed, VMG, tack heading ±180° (FI-501), ±60° (FI-502) ±10° (FI-501), ±5° (FI-502) - NMEA 2000: 2 ports - Wind sensor input: 1 port 2 WIND TRANSDUCER 2.1 2.2 2.3 2.4 2.
FI-505 COURSE PILOT SPECIFICATIONS OF FI-505 COURSE PILOT 1 GENERAL 1.1 1.2 1.3 1.4 1.5 Display Display Content Analog Meter Display Range Analog Meter Display Accuracy I/O Port 2 JUNCTION BOX (OPTION) 2.1 No. of I/O ports NMEA 2000 Device NMEA 2000 Backbone 3 12 VDC, less than 0.1 A 12 VDC, less than 1 A, max. 2A connectable ENVIRONMENTAL CONDITIONS 4.1 Useable Temperature Range 4.2 Relative Humidity 4.3 Waterproofing Display Unit Junction Box 4.
FI-506 RUDDER SPECIFICATIONS OF FI-506 RUDDER 1 GENERAL 1.1 1.2 1.3 1.4 Display Analog Meter Display Range Analog Meter Display Accuracy I/O Port 2 JUNCTION BOX (OPTION) 2.1 No. of I/O ports NMEA 2000 Device NMEA 2000 Backbone 3 12 VDC, less than 0.1 A 12 VDC, less than 1 A, max. 2A connectable A ENVIRONMENTAL CONDITIONS 4.1 Useable Temperature Range 4.2 Relative Humidity 4.3 Waterproofing Display Unit Junction Box 4.4 Vibration 5 6 ports 2 ports POWER SUPPLY AND POWER CONSUMPTION 3.
NAME OUTLINE INSTALLATION MATERIALS UNIT FI-501 000-167-804-10 M3X40 SUS304 000-167-826-10 M3 SUS304 000-167-453-10 M3 SUS304 000-167-404-10 M3 SUS304 000-163-884-10 3X20 SUS304 000-167-832-10 TZ7583002AO 100-340-471-10 19-028-3124-1 000-011-738-00 FI-501 1 Q'TY 2 2 2 2 4 1 1 CP26-00100 DESCRIPTION/CODE № LIST (略図の寸法は、参考値です。D IM EN S IO N S IN D R A W IN G FO R R EFER EN C E O N LY.
A-2 PACKING 1/1 26AA-X-9853 -0 LIST FI-5001 N A M E ユニット O U T L I N E DESCRIPTION/CODE № Q'TY UNIT 風向風速センサー 1 FI-5001 WIND TRANSDUCER 000-011-740-00 工事材料 INSTALLATION MATERIALS CP26-00201 +トラスタッピンネジ 1シュ 4 4X20 SUS304 SELF-TAPPING SCREW 000-158-850-10 図書 DOCUMENT 装備要領書 INSTALLATION MANUAL 1 IMC-72661-* ワ/エイ 000-167-285-1* 型式/コー ド番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりません。 TW O TYP ES A N D C O D ES M A Y B E LIS TED FO R A N ITEM .
A-3 PACKING 1/1 26AA-X-9857 -0 LIST FI-5002 N A M E ユニット O U T L I N E DESCRIPTION/CODE № Q'TY UNIT ジャンクションボックス 1 FI-5002 JUNCTION BOX 000-011-748-00 工事材料 INSTALLATION MATERIALS +トラスタッピンネジ 1シュ 2 4X20 SUS304 SELF-TAPPING SCREW 000-158-850-10 結束バンド 9 T18R WIRING BAND 000-167-891-10 電源ケーブル FI-5002-POWERCABLE CABLE ASSY.
A-4 PACKING 1/1 26AA-X-9854 -0 LIST CP26-00300/CP26-00400 N A M E 工事材料 O U T L I N E INSTALLATION MATERIALS DESCRIPTION/CODE № Q'TY +トラスタッピンネジ 1シュ 4 3X12 SUS304 SELF-TAPPING SCREW 000-167-824-10 ケーブル組品 1 FI-50-SENSOR-30/50 CABLE ASSY.
NAME OUTLINE INSTALLATION MATERIALS UNIT FI-502 000-167-804-10 M3X40 SUS304 000-167-826-10 M3 SUS304 000-167-453-10 M3 SUS304 000-167-404-10 M3 SUS304 000-163-884-10 3X20 SUS304 000-167-832-10 TZ7583002AO 100-340-471-10 19-028-3124-1 000-011-741-00 FI-502 1 Q'TY 2 2 2 2 4 1 1 CP26-00500 DESCRIPTION/CODE № LIST (略図の寸法は、参考値です。D IM EN S IO N S IN D R A W IN G FO R R EFER EN C E O N LY.
NAME OUTLINE INSTALLATION MATERIALS UNIT FI-505 000-167-804-10 M3X40 SUS304 000-167-826-10 M3 SUS304 000-167-453-10 M3 SUS304 000-167-404-10 M3 SUS304 000-163-884-10 3X20 SUS304 000-167-832-10 TZ7583002AO 100-340-471-10 19-028-3124-1 000-011-746-00 FI-505 1 Q'TY 2 2 2 2 4 1 1 CP26-00500 DESCRIPTION/CODE № LIST (略図の寸法は、参考値です。D IM EN S IO N S IN D R A W IN G FO R R EFER EN C E O N LY.
NAME OUTLINE INSTALLATION MATERIALS UNIT FI-506 000-167-804-10 M3X40 SUS304 000-167-826-10 M3 SUS304 000-167-453-10 M3 SUS304 000-167-404-10 M3 SUS304 000-163-884-10 3X20 SUS304 100-340-471-10 19-028-3124-1 000-167-832-10 TZ7583002AO 000-011-747-00 FI-506 1 Q'TY 2 2 2 2 4 1 1 CP26-00500 DESCRIPTION/CODE № LIST (略図の寸法は、参考値です。D IM EN S IO N S IN D R A W IN G FO R R EFER EN C E O N LY.
A-8 フラッシュマウントキット INSTRUMENTS FLUSH MOUNT KIT. FI-50 番 号 NO. 名 称 NAME CODE NO. 000-010-619-00 TYPE FI-50-FLUSH-KIT 用途/備考 REMARKS ※1 前面パネルF 1 1/1 数量 Q'TY 型名/規格 DESCRIPTIONS 略 図 OUTLINE 26AA-X-9401 -3 TZ7580002A0 FRONT PANEL 1 CODE NO. 000-167-885-10 ※1に貼付済み PRE-ATTACHED TO ※1. FURUNOロゴH3 2 19-028-1502-0 FURUNO STICKER H3 1 CODE NO. 100-339-580-10 ハードカバーF 3 TZ7580007AO COVER 1 CODE NO. 000-167-887-10 フラッシュマウントツール 4 TZ7580008AO FRAME 1 CODE NO.
Jul.24'07 R.
Jul.24'07 R.
Sep.21'07 R.
Jul.24'07 R.
% $ # &412 5*+'.& 0'6 5 0'6 % 0'6 * 0'6 . &412 5*+'.& 0'6 5 0'6 % 0'6 * 0'6 . &412 5*+'.& 0'6 5 0'6 % 0'6 * 0'6 . $#%-$10' 5*+'.& 0'6 5 0'6 % 0'6 * 0'6 . ធ⛯▫ ,70%6+10 $1: 0/'# 0'6914$#%-$10' &412 5*+'.& 0'6 5 0'6 % 0'6 * 0'6 . $#%-$10' 5*+'.& 0'6 5 0'6 % 0'6 * 0'6 . &412 5*+'.& 0'6 5 0'6 % 0'6 * 0'6 . ធ⛯▫ ,70%6+10 $1: 0/'# 0'6914$#%-$10' (+ 219'4%#$.' O ࠕࠞ 4'& 88 5# Z % ࠢࡠ $.- &412 5*+'.
䉺䉾䊏䊮䊈䉳↪ⓣ䋨㪋䊰ᚲ䋩 㪝㫆㫉㩷㫋㪸㫇㫇㫀㫅㪾㩷㫊㪺㫉㪼㫎㫊㩷㩿㪋㩷㫇㪺㫊㪅㪀 ኸಾ䉍䊗䊦䊃↪ⓣ䋨㪉䊰ᚲ䋩 㪝㫆㫉㩷㪹㫆㫃㫋㫊㩷㩿㪉㩷㫇㪺㫊㪅㪀
㪝㪠㪄㪌㪇䉲䊥䊷䉵㩷␜ㇱ䇭䊐䊤䉾䉲䊠䊙䉡䊮䊃↪ဳ⚕ 㪝㪠㪄㪌㪇㩷㫊㪼㫉㫀㪼㫊㩷㪛㫀㫊㫇㫃㪸㫐㩷㫌㫅㫀㫋㩷㪝㫃㫌㫊㪿㩷㪤㫆㫌㫅㫋㩷㪫㪼㫄㫇㫃㪸㫋㪼