Installation Manual COLOR LCD SOUNDER FCV-295 SAFETY INSTRUCTIONS ............................................................................ i SYSTEM CONFIGURATION ...................................................................... iii EQUIPMENT LISTS.................................................................................... iv 1. MOUNTING ............................................................................................ 1 1.1 1.2 1.3 Display Unit ...................................
SAFETY INSTRUCTIONS The installer must read the applicable safety instructions before attempting to install the equipment. WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION Indicates a potentially hazardous situation which, if not avoided, can result in minor or moderate injury.
CAUTION CAUTION Ground the equipment to prevent mutual interference. The transducer cable must be handled carefully, following the guidelines below. • Keep fuels and oils away from the cable. • Locate the cable where it will not be damaged. • The cable sheath is made of chlorophrene or polychloride vinyl, which are easily by damaged plastic solvents such as toulene. Locate the cable well away from plastic solvents.
SYSTEM CONFIGURATION Basic configuration is shown with solid line. Display unit CV-295 12-24 VDC Navigator Rectifier PR-62 100/110/115/ 220/230 VAC 1㱢, 50/60 Hz Water temperature sensor T-02MSB, etc. Speed/temp sensor ST-02MSB, etc. High Freq. Low Freq.
EQUIPMENT LISTS Standard supply Name Type Code No. Qty Display Unit CV-295 - Spare Parts SP02-05501 001-032-740 1 set Accessories FP02-05700 000-011-976 1 set Installation Materials CP02-08401 001-032-750 1 set Remarks 1 See packing list at back of this manual. Option Name Type Code No. Transducer Thru-hull pipe See next several pages. - Tank Cable Remarks MJ-A6SPF0003-050C 000-154-054-10 one end 6 pin, 5 m, for navigator CO-SPEVV-SBC 2Px0.
Combination of transducer, thru-hull pipe and tank Output (W) 1k/1k Frequency (kHz) 28/50 Ship type Steel FRP 28/88 Steel FRP 50/88 Steel FRP 50/200 Steel Transducer 28F-8 50B-9B 28F-8 88B-8 50B-9B 88B-8 FRP 50/200-1T 50/200-1ST Steel 50/200-12M FRP 1k/2k 28/200 Steel FRP 50/200 Steel FRP 88/200 Steel FRP 2k/2k 28/50 Steel FRP 28/82 Steel FRP 28/88 Steel FRP 28/200 Steel FRP Steel FRP 38/200 Steel FRP 50/82 Steel FRP 50/88 Steel FRP 50/200 Steel FRP Steel FRP 50/200 St
Output (W) 2k/2k Frequency (kHz) 28/107 Ship type Steel FRP 2k/3k 28/150 Steel FRP 50/107 Steel FRP 50/150 Steel FRP 3k/2k 68/200 Steel FRP 107/200 Steel FRP 3k/3k 28/38 Steel FRP Steel FRP 28/50 Steel FRP Steel FRP Steel FRP Steel FRP Steel FRP 28/88 Steel FRP Steel FRP 28/150 Steel FRP Steel FRP 28/200 Steel FRP Steel FRP 38/50 Steel FRP Steel FRP 38/88 Steel FRP Transducer 28F-18 100B-10R 28F-18 150B-12H 50B-12 100B-10R 50B-12 150B-12H 68F-30H 200B-8/8B 100B-10R 200B-8/8B 28
Output (W) 3k/3k Frequency (kHz) 38/150 Ship type Steel FRP 38/200 Steel FRP 50/88 Steel FRP Steel FRP Steel FRP 50/150 Steel FRP Steel FRP 50/200 Steel FRP Steel FRP Steel FRP 68/150 Steel FRP 68/200 Steel FRP 88/150 Steel FRP 88/200 1k 28 Steel Transducer 38BL-15HR 150B-12H 38BL-15HR 200B-12H 50BL-24H 88F-126H 50BL-24HR 88F-126H 50F-24H 88F-126H 50BL-24HR 150B-12H 50F-24H 150B-12H 50BL-24H 200B-12H 50BL-24HR 200B-12H 50F-24H 200B-12H 68F-30H 150B-12H 68F-30H 200B-12H 88F-126H 150B-12H
Output (W) 2k Frequency (kHz) 38 Ship type Steel Transducer 38BL-9HR FRP 50 Steel 50B-12 FRP Steel 50BL-12 FRP Steel 50BL-12HR FRP 82 Steel 82B-35R FRP 88 Steel 88B-10 FRP 200 Steel 200B-8/8B FRP 3k 28 Steel 28F-24H FRP Steel 28BL-12HR FRP 38 Steel 38BL-15HR FRP 50 Steel 50F-24H FRP Steel 50BL-24HR FRP Steel 50BL-24H FRP 68 Steel 68F-30H FRP 88 Steel 88F-126H FRP 107 Steel 100B-10R FRP 150 Steel 150B-12H FRP 200 Steel 200B-12H FRP viii Thru-hull pipe Tan
1. MOUNTING NOTICE Do not apply paint, anti-corrosive sealant or contact spray to coating or plastic parts of the equipment. Those items contain organic solvents that can damage coating and plastic parts, especially plastic connectors. 1.1 Display Unit WARNING Turn off the power at the switchboard before beginning the installation. Connect to a dedicated breaker in the power distributor. Fire or electrical shock can result if the power is left on.
1.2 Transducer The performance of the echo sounder depends upon the transducer position. A place least affected by air bubbles should be selected since turbulence blocks the sounding path. Further, select a place least influenced by engine noise. It is known that air bubbles are fewest at the place where the bow first falls and the next wave rises, at usual cruising speed. Note: The face of the transducer must be facing the sea bottom in normal cruising trim of the boat. 1.
Thru-hull mount water temperature sensor T-02MSB, T-03MSB Select a suitable mounting location considering the following points: • Select a mid boat flat position. The sensor does not have to be installed perfectly perpendicular; however, the location should not be such that the transducer may be damaged when the boat is dry-docked. • Locate away from equipment which gives off heat. • Locate away from drain pipes. • Select a location where vibration is minimal.
Through-hull mount water temperature/speed sensor ST-02MSB, ST02-PSB Select a suitable mounting location considering the following: • Select a mid-boat flat position. The sensor does not have to be installed perfectly perpendicular. The sensor must not be located where it might get damaged in dry-docking operation. • Select a place apart from equipment generating heat. • Select a place in the forward direction viewing from the drain hole, to allow for circulation of cooling water.
2. WIRING 2.1 Interconnection Refer to the interconnection diagram at the back of this manual for detailed information. Display unit rear panel (connector cover removed) DPYCY-1.5 Rectifier PR-62 100/110/115/ 220/230 VAC 1φ, 50/60 Hz MJ-A6SPF0003-050C Grounding wire: As short as possible DPYCY-1.5 IV-2.0sq Navigator High Speed/ Water temperature sensor 12-24 VDC (Connect to a dedicated breaker in the power distributor.
2.2 Cable Fabrication Power cable This echo sounder is designed to be powered with 12-24 VDC. Use the cable DPYCY-1.5 (Japan Industry Standard) or equivalent. 6 3 Approx. 70 30 DPYCY-1.5 Armor Sheath Armor Vinyl tape Sheath Sheath Crimp-on lug FV2-M4 Ǟ = 13.7 mm Clamp armor with cable clamp. Conductor S = 1.5 mm Ǟ = 1.56 mm 2 (AWG16) Transducer cable Separate the transducer cable well away from power cables to prevent interference.
WAGO connector (for transducer and NMEA ports) Press Opener (big one: for transducer port small one: for NMEA port) 1. Twist conductors. 2. Insert opener and press it down. 3. Insert core to hole. 4. Release opener. 5. Pull the core to confirm that it is tightly fastened. Twist. Core NMEA port Connect a GPS navigator, etc. to NMEA port J2 #1 to #4. You can connect two sensors (for example, GPS receiver GP-310B and smart sensor).
2.
3. INITIAL SETTING This chapter provides the information necessary for initial setup of the equipment. First turn on the power and set display language. Then, set transducer used, by model number (FURUNO transducer only) or by specifications. 3.1 Language Setting 1. Press [ /BRILL] key to turn on the power. The following display appears. Language setting screen 2. Press T or S to select a desired language, and then press the ENTER key to set. The units setting screen appears. Unit setting screen 3.
4. Press T or S to select necessary unit and then press the ENTER key to set. • Depth: m, ft, fa, pb, HR (Japanese unit) • Temp: °C, °F • Speed: kt, km/h, mph • Wind: kt, km/h, mph, m/h • Distance: nm, km, sm 5. Press the MENU key. The following message appears. 6. Press any key. The transducer setting screen appears. Proceed to next section. 3.2 Transducer Data CAUTION Set the transducer model number properly. Wrong transducer setting can damage the transducer and void the warranty.
1. At the transducer setting screen, confirm that "XDCR Select" is set to "XDCR Type" (default setting). Transducer setting screen 2. If a high frequency transducer is fitted, press T to select "HF Connection" and then press the ENTER key. Connected Not connected 3. Press S to select "Connected" and then press the ENTER key. 4. Press T to select "Freq" and then press the ENTER key. 5. Press T or S to select the transducer frequency and then press the ENTER key.
6. Press T to select "Transducer" and then press the ENTER key. The list of programmed transducers appears. 200B-5S 50/200-1T 50/200-1ST 200B-8B 200B-12H (Example: 200 kHz) 7. Press T to S select transducer connected and then press the ENTER key. 8. Jot down the alphabet which appears on the "Tap" line. You may need to change the tap setting at the rear of the display unit depending on the transducer type which is connected. For details, see below. 9.
Entering transducer data by transducer specifications To connect the transducers which are not programmed, do as follows: Note: The transducers of 53 - 65 kHz, 111 to 139 kHz and 171 - 183 kHz cannot be connected to the FCV-295 because of noise. 1. At the XDCR Setting dialog box, select "XDCR Select" and press the ENTER key. The following screen appears. XDCR Type Manual 2. Press T to select "Manual", and then press the ENTER key. 3.
3. Press T to select "Temp" and then press the ENTER key. Temperature calibration screen 4. Press T or S to set the value for the temperature calibration and then press the ENTER key. For example, if the temperature indication is 2.5°C higher than the actual value, set “-2.5°C”. 5. To calibrate the speed value, press T to select "Speed(STW)" and then press the ENTER key. 6. Press T or S to set the value for the speed calibration and then press the ENTER key.
3.4 NMEA Port Setting If a GPS navigator and/or other sensor are connected, set up as follows. 1. Press the MENU key. 2. Press T to select "System" and "NMEA" and then press the ENTER key. NMEA setting menu 3.Press T to select the item to set and then press the ENTER key. 4.Press T or S to select an appropriate one and then press the ENTER key. Description for each item of the NMEA menu NMEA0183: Choose NMEA0183 version of navigation equipment connected to the NMEA port, among Ver. 1.5, Ver. 2.0 or Ver.
WAAS Setup: Choose how to use the WAAS signal when connecting with a WAAS capable GPS receiver, for example GP-320B/330B. The message types (WAAS-00 to WAAS-27) are used as WAAS correction. Choose WAAS-00 to enable WAAS. TLL Output: Output the position selected by the MARK key to the plotter connected. • Off: Does not output latitude/longitude. • TLL: Outputs latitude/longitude. • FURUNO-TLL: Outputs latitude/longitude, depth and water temperature. This requires FURUNO-TLL enabled device.
APPENDIX TRANSDUCER 82B-35R The 82B-35R is a transducer with wide bandwidth of 65 kHz-110 kHz. It is constructed to provide protection against slamming. Transducer, thru-hull pipe and tank list Frquency (kHz) 15/88 Transducer 15F-4S/82B-35R 15F-10/82B-35R 28/88 50/88 28F-18/82B-35R 50F-8G/82B-35R 50B-12/82B-35R 88/200 82B-35R/200B-8/ 200B-8B/200B-8N Hull Material Tank (Code No.) Fasten inside hull (Code No.) Fasten outside hull (Code No.
Setting for dual frequency transmitting 1. Set the XDCR SELECT menu as follows (see page 11 and 12). Setting for “HF” connection Setting for “LH” connection 2. Press the [PWR] key to turn the power off, and turn it on again. 3. Press the MENU key to show the menu. 4. Select the [Sounder] and press the ENTER key. 5. See the section "1.19.1 Sounder menu" in the Operator's Manual for how to set "Freq Choice" and "Freq Control" for high and low frequencies.
NAME SPARE PARTS UNIT FCV-295-J/E 000-157-229-10 FV2-M4 000-165-800-10 231-131 000-162-608-10 5X20 SUS304 100-344-030-10 02-160-1201-0 100-332-651-10 02-155-1082-1 000-157-492-10 FGMB 125V 6A PBF 000-011-835-00 CV-295 1 Q'TY 2 1 4 1 CP02-08401 1 FP02-05700 4 SP02-05501 ** DESCRIPTION/CODE № LIST (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) コ-ド番号末尾の[**]は、選択品の代表コードを表します。 CODE NUMBER ENDING WITH "**" INDICATES THE CODE NUMBER OF REPRESENTATIVE MATERIAL.
Nov.12'07 R.
Nov.12'07 R.
C B A 3 4 5 6 *3 DPYC-1.5 *1 (-) (+) 1 2 *2 シロ WHT クロ BLK P P 3 RD-A 4 RD-B 7 SHIELD J2 1 TD-A(RD-A) 2 TD-B(RD-B) NOTE *1: SHIPYARD SUPPLY. *2: OPTION. *3: CONNECTOR PLUG FITTED AT FACTORY. *4: CONNECT THE 82B-35R TRANSDUCER TO EITHER HF OR LF. 注記 *1)造船所手配。 *2)オプション。 *3)コネクタは工場にて取付済み。 *4)送受波器82B-35RはHF/LFのいずれかに接続。 TD-B NAV2 TD-A TD-B NAV1 TD-A 2台接続の場合(メニューにて設定変更) TWO SETS CONNECTION (CHANGE SETTING FROM MENU) P MJ-A6SPF MJ-A6SPF0003,5m,φ6 航法装置など キ YEL NAV EQUIPMENT 1 P ミドリ GRN 2 ETC.
The paper used in this manual is elemental chlorine free. ・FURUNO Authorized Distributor/Dealer 9-52 Ashihara-cho, Nishinomiya, 662-8580, JAPAN Telephone : +81-(0)798-65-2111 Fax : +81-(0)798-65-4200 All rights reserved. Printed in Japan A : APR . 2008 B : OCT . 05, 2009 Pub. No.