Operator's Manual
2. WIRING
10
5. Loosen the two screws fixing the clamp fixing plate to detach the plate.
6. Pass the sealing nut (unfastened at step 4) onto the transducer cable and pass the cable
through the super gland and into the unit.
7. Use the WAGO connector opener, attached inside the equipment, to connect the transducer
cable to the WAGO connectors, following the instructions in the figure below and the intercon-
nection diagram.
8. Attach the WAGO connectors.
9. Refasten the clamp fixing plate, referring to the table below for how to orient the plate.
Transducer type Clamp fixing plate orientation
CM265LH Projection on plate upward
B265LH Projection on plate downward
Clamp fixing plate
1. Twist conductors.
2. Insert opener as directed and press it down.
3. Insert core to hole.
4. Release opener.
5. Pull the core to make sure it is correctly inserted.
WAGO connector opener
Core
Twist.
Push