Brochure
Table Of Contents
- 2 3RV1 Circuit Breaker/MSP 1)
- 2.1 Specifications/regulations/approvals
- 2.2 Device description
- 2.3 Application and areas of use
- 2.4 Accessories
- 2.4.1 Attachable accessories: Overview
- 2.4.2 Auxiliary contacts 3RV19 01-.., alarm switch 3RV19 21-111 and auxiliary release 3RV19 .2-....
- 2.4.3 Motorized remote-control mechanism 3RV19 .6-....
- 2.4.4 Disconnecting/isolator module 3RV19 .8-1A
- 2.4.5 Thru-the door rotary operators 3RV19 .6-..
- 2.4.6 Terminals for "Combination Motor Controller Type E" in acc. with UL 508
- 2.4.7 Enclosures and mounting accessories
- 2.4.8 Busbar adapter 8US1 (Fastbus system)
- 2.4.9 Isolated 3-phase busbar system
- 2.4.10 Link module for connection to a contactor
- 2.5 Mounting and connection
- 2.6 Dimensional drawings (measurements in mm)
- 2.7 Technical specifications
- 2.7.1 General specifications
- 2.7.2 Permissible rating of approved devices for North America, u s
- 2.7.3 Short-circuit breaking capacity Icn in acc. with IEC 60 947-2
- 2.7.4 Limiter function with standard devices for 500 VAC and 690 VAC in acc. with IEC 60 947-2
- 2.7.5 Characteristics
- 2.7.6 Installation guidelines
- 2.8 Application notes for the use of 3RV1 downstream from frequency converters/ inverter with pulsing voltage
Circuit Breaker/MSP 3RV1
SIRIUS System Manual
GWA 4NEB 430 0999-02 DS 01
2-69
2.7.3 Short-circuit breaking capacity I
cn
in acc. with IEC 60 947-2
The table lists the rated limit short-circuit breaking capacity I
cu
and the rated service short-circuit breaking capacity I
cs
of 3RV1 circuit
breakers with different inception voltages and related to the rated current I
n
of the circuit breakers.
The incoming supply of the circuit breakers is permissible at the upper or lower terminals irrespective of the rating.
If the short-circuit current at the installation location exceeds the rated short-circuit breaking capacity of the circuit breaker specified in
the table, a backup fuse is required. You can also use an upstream circuit breaker with a limiter function.
The maximum rated current of this backup fuse is specified in the tables. The rated short-circuit breaking capacity specified for the
fuse then applies.
Circuit breaker/contactor combinations for short-circuit currents of up to 50 kA can be used as fuseless load feeders in acc. with Part 5.
Circuit
breaker
Rated
current
I
n
To 240 VAC
2
)To 400 VAC
2
)/415 V
3
) To 440 VAC
2
)/460 V
3
) To 500 VAC
2
)/525 V
3
) To 690 VAC
2
)
I
cu
I
cs
Max. I
cu
I
cs
Max. I
cu
I
cs
Max. I
cu
I
cs
Max. I
cu
I
cs
Max.
Fuse Fuse Fuse Fuse Fuse
(gL/gG) (gL/gG) (gL/gG) (gL/gG) (gL/gG)
Type A kA kA A kA kA A kA kA A kA kA A kA kA A
3RV10,
3RV16 11-
0BD10
frame size S00
0.16 to 0.8
100 100 • 100 100 • 100 100 • 100 100 • 100 100 •
1
100 100 • 100 100 • 100 100 • 100 100 • 100 100 •
1. 2 5
100 100 • 100 100 • 100 100 • 100 100 •2220
1. 6
100 100 • 100 100 • 100 100 • 100 100 •2220
2
100 100 • 100 100 • 100 100 • 101035 2 235
2.5
100 100 • 100 100 • 100 100 • 101035 2 235
3.2
100 100 • 100 100 • 50 10 40
1
)3340 2240
4
100 100 • 100 100 • 50 10 40
1
)3340 2240
5
100 100 • 100 100 • 50 10 50
1
)3350 2250
6.3
100 100 • 100 100 • 50 10 50
1
)3350 2250
8
100 100 • 50 12.5 80
1
) 50 10 63
1
)3363 2263
10
100 100 • 50 12.5 80
1
)1010 63 3 363 2 263
12
100 100 • 50 12.5 80
1
)1010 80 3 380 2 280
3RV1. 2
Frame size S0
0.16 to 1.25
100 100 • 100 100 • 100 100 • 100 100 • 100 100 •
1. 6
100 100 • 100 100 • 100 100 • 100 100 • 100 100 •
2
100 100 • 100 100 • 100 100 • 100 100 •8825
2.5
100 100 • 100 100 • 100 100 • 100 100 •8825
3.2
100 100 • 100 100 • 100 100 • 100 100 •8832
4
100 100 • 100 100 • 100 100 • 100 100 •6332
5
100 100 • 100 100 • 100 100 • 100 100 •6332
6.3
100 100 • 100 100 • 100 100 • 100 100 •6350
8
100 100 • 100 100 • 50 25 63
1
)422163 6 350
10
100 100 • 100 100 • 50 25 80
1
)422163 6 350
12.5
100 100 • 100 100 • 50 25 80
1
)422180 6 363
16
100 100 • 50 25 100
1
) 50 10 80
1
) 10 5 80 4 2 63
20
100 100 • 50 25 125
1
) 50 10 80
1
) 10 5 80 4 2 63
22
100 100 • 50 25 125
1
) 50 10 100
1
) 10 5 80 4 2 63
25
100 100 • 50 25 125
1
) 50 10 100
1
) 10 5 80 4 2 63
3RV1. 3
Frame size S2
16
100 100 • 50 25 100
1
) 50 25 100
1
) 12 6 63 5 3 63
20
100 100 • 50 25 125
1
) 50 25 100
1
) 12 6 80 5 3 63
25
100 100 • 50 25 125
1
) 50 15 100
1
) 12 6 80 5 3 63
32
100 100 • 50 25 125
1
) 50 15 125
1
)10 5100 4 263
40
100 100 • 50 25 160
1
) 50 15 125
1
)10 5100 4 263
45
100 100 • 50 25 160
1
) 50 15 125
1
)10 5100 4 263
50
100 100 • 50 25 160
1
) 50 15 125
1
)10 5100 4 280