Brochure
Table Of Contents
- 2 3RV1 Circuit Breaker/MSP 1)
- 2.1 Specifications/regulations/approvals
- 2.2 Device description
- 2.3 Application and areas of use
- 2.4 Accessories
- 2.4.1 Attachable accessories: Overview
- 2.4.2 Auxiliary contacts 3RV19 01-.., alarm switch 3RV19 21-111 and auxiliary release 3RV19 .2-....
- 2.4.3 Motorized remote-control mechanism 3RV19 .6-....
- 2.4.4 Disconnecting/isolator module 3RV19 .8-1A
- 2.4.5 Thru-the door rotary operators 3RV19 .6-..
- 2.4.6 Terminals for "Combination Motor Controller Type E" in acc. with UL 508
- 2.4.7 Enclosures and mounting accessories
- 2.4.8 Busbar adapter 8US1 (Fastbus system)
- 2.4.9 Isolated 3-phase busbar system
- 2.4.10 Link module for connection to a contactor
- 2.5 Mounting and connection
- 2.6 Dimensional drawings (measurements in mm)
- 2.7 Technical specifications
- 2.7.1 General specifications
- 2.7.2 Permissible rating of approved devices for North America, u s
- 2.7.3 Short-circuit breaking capacity Icn in acc. with IEC 60 947-2
- 2.7.4 Limiter function with standard devices for 500 VAC and 690 VAC in acc. with IEC 60 947-2
- 2.7.5 Characteristics
- 2.7.6 Installation guidelines
- 2.8 Application notes for the use of 3RV1 downstream from frequency converters/ inverter with pulsing voltage
Circuit Breaker/MSP 3RV1
SIRIUS System Manual
GWA 4NEB 430 0999-02 DS 01
2-53
2.6 Dimensional drawings (measurements in mm)
Circuit Breaker/MSP 3RV1
Fig. 2-42: 3RV10 31, 3RV13 31, 3RV14 31 (Frame size S2)
Fig. 2-43: 3RV10 4, 3RV13 4 (Frame size S3)
Fig. 2-40: 3RV10 11, 3RV16 (Frame size S00) Fig. 2-41: 3RV10 21, 3RV13 21, 3RV14 21 (Frame size S0)
1) side-mount auxiliary contacts, 2-pole 7) Drilling pattern
2) Alarm switch (S0 to S3) or side-mount auxiliary contacts,
(4-pole S00 to S3)
8) 35 mm rail in acc. with EN 50022
3) Auxiliary release 9)
Mounting onto 35 mm rail, 15 mm high, in acc. EN 50 022
or
with EN 50 022
or 75 mm rail in acc. with EN 50023
4) Transverse auxiliary switch
5) Push-in lugs for screw mounting 10)4 mm Allen screw
6) Only with undervoltage release with leading auxiliary switch 11)Lockable in 0 position with shackle (5 mm in diameter
1)
11)
3) 4)5)
8)
NS
B
0
0
0
2
6
c
45
90
70
76
9 18
62
5
45
12
45
3,
5
6)
2)
18
25
5
105
7)
11)
2)
5) 4)
8)
3)1)
NS
B
0
0
0
2
7
b
45
14
12
90
97
45
5
56
80
91
45
69
18 18
72
9
5
25
106
7)
20
5518 18
45
85
109
121
127
5
8
132
144
140
89
125
1)
2)
3)
4)
8)
NS
B
0
0
0
2
8
a
11)
9
5
30
130
7)
4
5
7018 18
1
1
6
1
6
5
1
5
0
5
7
8
132
153
157
146
10)11)
1)
2)
3)
4)
9)
N
S
B
0
0
0
2
9
b
169
9
5
30
1
5
5
7)