Brochure
SIRIUS
Siemens Industry, Inc. Industrial Control Product Catalog 2017
1/5
1
MOTOR STARTER
PROTECTORS
Note: Select MSP by motor Full Load Amperes. Horsepower ratings are for reference only.
1) Select motor starter protector by motor full load amps.
Horsepower ratings for reference only.
2) Size S2 and S3 are listed as type E combination motor
controllers. For required Type E terminals see page 1/10.
3RV2031 MSPs with a current setting limit of 45A or less
do not require a type E terminal and fulfill the spacing
requirements of UL508.
3) Shaded ratings apply for group installation only. These
ratings do not apply as UL listed manual combination
starters.
4) Pre-assembled motor starter protector and transverse
auxiliary switch with 1NO + 1NC is available. Replace the
last digit of the order no. with a “5”.
5) 3RV1 MSPs can only be used with 3RT1 contactors
and accessories. 3RV2 MSPs can only be used with
3RT2 contactors and accessories.
6) For 100kA SCCR rated MSPs, change the part number
from 3RV2031 to 3RV2032. (applies to S2 frame only
through 65A).
Refer to pages 1/18 to 1/20 when using an MSP in a Manual Motor Starter or a Manual Self-Protected Combination Motor Controller.
Illustration
FLA
Adjustment
Range
[A]
Single Phase
HP rating
1)
3 Phase
HP Rating
1)
Inst.
Short-
Circuit
Release
[A]
UL AIC
(480V)
[kA]
6)
Trip Class 10
Order Number
4)
Trip Class 20
Order Number
4)
115V 240V 200V 230V 460V 575V
3RV203 Frame Size S2
9.5 - 14 1.5 3 5 5 10 15 208 65 3RV2031-4SA10 3RV2031-4SB10
12 - 17 1.5 3 5 7.5 15 15 260 65 3RV2031-4TA10 3RV2031-4TB10
14 - 20 1.5 3 7.5 7.5 15 20 260 65 3RV2031-4BA10 3RV2031-4BB10
18 - 25 2 5 7.5 10 20 25 325 65 3RV2031-4DA10 3RV2031-4DB10
22 - 32 3 5 10 10 25 30 416 65 3RV2031-4EA10 3RV2031-4EB10
28 - 36 3 7.5 15 15 30 40 520 65 3RV2031-4PA10 3RV2031-4PB10
32 - 40 3 7.5 15 15 30 40 585 65 3RV2031-4UA10 3RV2031-4UB10
35 - 45 3 10 15 15 40 50 650 65 3RV2031-4VA10 3RV2031-4VB10
42 - 52 5 10 15 20 40 50 741 65 3RV2031-4WA10 3RV2031-4WB10
49 - 59 5 15 20 25 50 60 845 30 3RV2031-4XA10 3RV2031-4XB10
54 - 65 5 15 20 25 50 60 845 30 3RV2031-4JA10 3RV2031-4JB10
3RV204 Frame Size S3
28 - 40 3 7.5 15 15 30 40 520A 65 3RV2041-4FA10 3RV2041-4FB10
36 - 50 5 10 15 20 40 50 650A 65 3RV2041-4HA10 3RV2041-4HB10
45 - 63 5 15 20 25 50 60 819A 65 3RV2041-4JA10 3RV2041-4JB10
57 - 75 7.5 15 25 25 60 75 975A 65 3RV2041-4KA10 3RV2041-4KB10
65 - 84 7.5 15 25 30 60 75 1170A 65 3RV2041-4RA10 3RV2041-4RB10
75 - 93 7.5 20 30 40 75 100
3)
1300A 65 3RV2041-4YA10 3RV2041-4YB10
80 - 100 10 25 40 40 75 100
3)
1300A 65 3RV2041-4MA10 3RV2041-4MB10
Description Ordering Information
The 3RV203 / 204 MSPs are UL approved as Self Protected Combination Motor Controllers
which are also called Type E. In this application, all the required functions for a motor
branch are provided in one device: disconnect, short circuit protection, motor control and
overload protection. A type E terminal adaptor is required for all S2 frame 3RV2031 above
45A and all S2 frame 3RV2032 as well as for all S3 frame motor starter protectors.
The 3RV203 / 204 MSPs are also approved for use as follows:
– Manual Motor Controller: Motor starter, motor disconnect, control and overload
protection.
– Group Installation: Motor starter only, motor disconnect, control and overload protection.
– Tap conductor Protection in Group Installation acc. NEC: Motor starter only; motor
disconnect, control and overload protection.
When the 3RV203 / 204 is used with one of the 3 above mentioned approvals, they can be
installed downstream of one circuit breaker or fuse set.
For more detailed application information and rules how to apply, size and rate these
MSPs in control panels in general, in group installations or in accordance to international
IEC standards visit our website: www.usa.siemens.com/controlpaneldesign
E
ON/OFF rotary handle with lockout and visible
trip indication.
E
Adjustment dial for setting to motor FLA.
E
Class 10 overload trip characteristics.
E
Short circuit trip at 13 times the maximum set-
ting of the FLA adjustment dial.
E
Short circuit current rating:
E
Ambient compensated up to 140° F (applies to
side by side mounting).
E
Phase loss sensitivity.
E
Test trip function.
E
Auxiliaries and Accessories see pages 1/7–1/17.
E
General Information see pages 1/29–1/32.
E
Technical Data see pages 1/18–1/28.
E
Dimensions see page 1/33.
Siemens / Industrial Controls Previous folio: IC10 1/5
3RV Motor Starter Protectors
For Motor Protection
3RV10 Class 10 & 20
—
up to 100A
Product Category IEC