Product Overview
Table Of Contents
- 3RT1 contactors/3RH1 control relays
- 3.4 Accessories
- 3.4.1 Attachable auxiliary switches for extending the auxiliary contacts
- 3.4.2 Time-delay auxiliary switches
- 3.4.3 Solid-state time relay blocks with semiconductor output
- 3.4.4 Additional load module (3RT1916-1GA00)
- 3.4.5 Coupling element for frame sizes S0 to S3 (3RH1924-1GP11)
- 3.4.6 Surge suppression
- 3.4.7 Other accessories
- 3.4.7.1 LED module for indicating contactor control (3RT1926-1QT00)
- 3.4.7.2 Auxiliary connecting lead terminal, 3-pole for frame size S3 (3RT19 46-4F)
- 3.4.7.3 Box terminal blocks
- 3.4.7.4 EMC interference suppression module (3RT1916-1P..)
- 3.4.7.5 Soldering pin adapter for frame size S00 (3RT19 16-4KA.)
- 3.4.7.6 Paralleling links (3RT19 .6-4B.31)
- 3.4.7.7 Sealing cover (3RT19 .6-4MA10)
- 3.4.7.8 Terminal covers for frame sizes S2 to S12
- 3.4 Accessories
3RT1 contactors/3RH1 control relays
SIRIUS System Manual
3-86 GWA 4NEB 430 0999-02 DS 01
3.4.1.1 Terminal markings of the contactors frame sizes S00 to S12
In contactors of frame size S00 with an integrated auxiliary contact, the ter-
minal marking complies with EN 50 012. This also applies to contactors that
are available as complete devices, frame sizes:
• S0 to S3 with mounted auxiliary contact blocks 2 NO + 2 NC
• S6 to S12 with side mounted auxiliary contact blocks 2 NO + 2 NC
Expanding the contac-
tors of frame size S00
All the contactors of frame size S00 (3 and 4-pole) can be expanded with
auxiliary switch blocks with the identification numbers 40 to 02 in acc. with
EN 50 005 as follows:
• Frame size S00 with an integrated auxiliary contact (identification number
10E or 01) for contactors with 3 or 5 auxiliary contacts
• Frame size S00 with 4 main contacts for contactors with 2 or 4 auxiliary
contacts
Note
The identification numbers on the auxiliary switch blocks only apply to the
attached auxiliary switches.
Expanding the contac-
tors with 1 integrated
NO contact, S00
(3RT101.-...01)
Contactors with one NO contact as an auxiliary contact with screw-type or
Cage Clamp terminals, identification number 10E, can be expanded with
auxiliary switch blocks with terminal markings in acc. with DIN EN 50 012
for contactors with 2, 4, and 5 auxiliary contacts. The terminal markings of
the complete contactors comply with EN 50 012. The identification numbers
11E, 22E, 23E, and 32E on the auxiliary switch blocks apply to the complete
contactors.
Important
Auxiliary switch blocks in acc. with EN 50 012 can only be combined with
contactors of frame size S00 that have 1 NO contact in the basic unit
because they are coded. These auxiliary switch blocks cannot be combined
with contactors that have an NC contact in the basic unit (identification num-
ber 01).