Brochure

SIRIUS
Siemens Industry, Inc. Industrial Control Product Catalog 2017
2/19
2
COnTACTORS And
ASSEMbliES
Siemens / Industrial Controls Previous folio: IC10 2/15
IEC 60947-5, DIN EN 60947-5-1,
(VDE 0660 Part 200)
The contactors are suitable for
use in any climate and are
finger safe per DIN EN 50274.
The 3RT26 capacitor contactors
are application specific variants
of the size S00 to S2 SIRIUS
Innovations contactors. The
capacitors are precharged by
means of the mounted leading
NO contacts and resistors; only
then do the main contacts close.
This prevents disturbances in
the power system and welding
of the contactors.
Only discharged capacitors are
permitted to be switched on
with capacitor contactors.
Recommendation: use dis-
charge chokes for parallel con-
nection with the capacitors.
The capacitor contactors of
size S00 contain either 1NO
or 1NC in the basic unit and
another unassigned NC
contact in the auxiliary switch
block fitted to the basic unit.
The auxiliary switch block
which is snapped onto the
capacitor contactor of sizes
S0 contains the three leading
NO contacts and one stan-
dard NO contact, which is
unassigned.
The capacitor contactors of
size S2 can be fitted addition-
ally with a 2-pole auxiliary
switch on the right side (2 NO,
2 NC or 1 NO + 1 NC), type
3RH19 21-1EA.. for lateral
mounting.
For the capacitor making and
breaking capacity of the basic
3RT20 contactor variant, see
the technical data.
AC-6b utilization category
For switching three-phase capacitors at an
ambient temperature of 60 °C
2
)
Current Auxiliary
contacts,
unassigned
Rated control
supply voltage
U
s
1) 3)
Screw connection
Weight
approx.
UL capacitor rating at operational voltage
Order No.
200/208 230/240 460/480 575/600
kvarPhase kvar kvar kvar AC kg
For screwing and snapping onto 35 mm standard mounting rail
Size S00
18108.343.6
17146.96.2
13115.34.8
23189.18.3
24 V, 50/60 Hz
0.24
120 V, 60 Hz
240 V, 60 Hz
24 V, 50/60 Hz
120 V, 60 Hz
240 V, 60 Hz
24 3RT26 25-1AC25 0.49
3RT26 25-1AK65
3RT26 25-1AP65
Size S2
14 16 33 40 72A 2 NC
1NO / 1NC
1NO / 2NC
1NO / 2NC
1NO / 2NC
1NO / 2NC
1.11
25 27 55 69
3RT26 37-1NB35
3RT26 37-1NF35
3RT26 37-1NP35
20 22 45 54 98A 2 NC 20-33 VUC
83-155 VUC
175-280 VUC
23-33 VUC
83-155 VUC
175-280 VUC
1.11
34 38 75 94
AC operation
Selection and ordering data
AC operation
3RT26 17-1AK63
3RT2637-1NF35
1) Coil voltage tolerance: 0.85 ... 1.1 x U
s
.
2) A clearance of 10 mm is required for side-by-side mounting at ambient temperatures > 60 °C
3RT26 36-1NB35
3RT26 36-1NF35
3RT26 36-1NP35
3RT26 17-1AB03
3RT26 17-1AK63
3RT26 17-1AP63
Size S0
16136.45.8
28221110
24 V, 50/60 Hz
120 V, 60 Hz
240 V, 60 Hz
29 3RT26 26-1AC25 0.49
3RT26 26-1AK65
3RT26 26-1AP65
18157.36.6
31251311
24 V, 50/60 Hz
120 V, 60 Hz
240 V, 60 Hz
33 3RT26 27-1AC25 0.49
3RT26 27-1AK65
3RT26 27-1AP65
24209.58.6
41331615
24 V, 50/60 Hz
120 V, 60 Hz
240 V, 60 Hz
43 3RT26 28-1AC25 0.59
3RT26 28-1AK65
3RT26 28-1AP65
For further voltages, see page 2/49.
For auxiliaries and accessories,
see page
2/66
-
2/83
.
For technical data, see page 2/170.
For wiring diagram, see page 2/198.
For dimension drawings, see page 2/217.
DC Coil Selection for 3RT261 only
●●
Coil Code
B4 W4 E4 F4 G4 M4
DC 24 V 48 V 60 V 110 V 125 V 220 V
UC Coil Selection for 3RT262 UC Coil Selection for 3RT263
●●
Coil Code
NB3 NF3 NP3
●● Coil Code
B3 F3 P3
UC 21-28V 95-130V 200-280V 20-33V 83-155V 175-280V
3) at upper limit = 1.1 x U
s
Contactors and Contactor Assemblies
Contactors for Special Applications
3RT26 capacitor contactors
Product Category IEC