Submittal Sheet

• at DC 1/h 10,000
Frequency of operation / at AC-1 / according to IEC 60947-6-2 1/h 1,000
Frequency of operation / at AC-2 / according to IEC 60947-6-2 1/h 750
Frequency of operation / at AC-3 / according to IEC 60947-6-2 1/h 750
Frequency of operation / at AC-4 / according to IEC 60947-6-2 1/h 250
Control circuit:
Type of voltage / of the controlled supply voltage AC
Control supply voltage / 1
• at 50 Hz / for AC / rated value V 110
• at 60 Hz / for AC / rated value V 120
Operating range factor control supply voltage rated value / of
the magnet coil
• at 50 Hz / for AC 0.8 … 1.1
• at 60 Hz / for AC 0.85 … 1.1
Apparent pull-in power / of the solenoid / for AC V·A 43
Apparent holding power / of the solenoid / for AC V·A 6.5
Inductive power factor
• with the pull-in power of the coil 0.8
• with the pull-in power of the coil 0.25
Closing delay
• at AC ms 8 … 33
Opening delay
• at AC ms 4 … 15
Arcing time ms 10 … 15
Auxiliary circuit:
Contact reliability / of the auxiliary contacts 1 faulty switching per 100 million (17 V, 1 mA)
Number of NC contacts / for auxiliary contacts / instantaneous
switching
0
Number of NO contacts / for auxiliary contacts / instantaneous
switching
1
Operating current / of the auxiliary contacts
• at AC-12 / maximum A 10
• at AC-15
• at 230 V A 10
• at 400 V A 3
• at DC-12
• at 48 V A 6
• at 60 V A 6
• at 110 V A 3
3RT2017-1AK61
Page 3/ 07/27/2012
subject to modifications
© Copyright Siemens AG 2012
7