Brochure

9
GENERAL PURPOSE
CONTROL
Siemens Industry, Inc. Industrial Control Product Catalog 2017
9/15
Ordering Information
Replace the (*) with a letter from the coil table. Dual voltage coils are wired
on high voltage unless specified on order.
Heater elements see page 9/124. Single phase starters require 1 heater
element. 3-phase starters require 3 heater elements.
Field Modification Kits page 9/104.
Factory Modifications page 9/119.
Dimensions see page 9/140 open and 9/157 enclosed.
Wiring Diagrams see page 9/173.
Replacement Parts see page 9/131.
For NO/NC SPDT contact on overload relay, replace "81" with "91".
"81" indicates one NC contact.
Note:
Hp’s shown above are based on the overload amp
range for the FLA’s (per the National Electric Code)
of typical industrial motors. All Starter Sizes carry
one maximum Hp rating. For higher Hp single phase
motors, use 3-phase starters, wire and set per diagram
on page 9/173.
a
To receive a single phase starter in an extra wide enclo-
sure, order the enclosure kit from pg 16-91 and the open
style starter from pg 16-14 or 16-16 as separate items.
b
For conduit hubs and conversion instructions, see page 9/110.
c
Coils D, F, or G will be wired for incoming voltage.
J coil will be wired for separate source. Coils E, H,
and L do not apply to single phase starters.
Standard Auxiliary Contacts, Same as Contactors, refer to
page 9/60.
Coil Table
60Hz Voltage Letter
24 J
120 F
110–120/220–240 A
200–208 D
220–240 G
277 L
220–240/440–480 C
440–480 H
575–600 E
For other voltages and frequencies,
see Factory Modifications page 9/119.
Open Type & Standard Width Enclosure, 3-Phase, 3-Pole
Max Hp
Cont-
actor
Amp
Rating
NEMA
Size
Half
Size
Enclosure
200
Volts
230
Volts
460
Volts
575
Volts
Open Type
Standard Auxiliary
Contacts
NEMA 1
General Purpose
NEMA 4/4X
Stainless
b
Watertight, Dust-tight
Corrosion Resistant
@ = W for 304 Stainless
@ =
X for 316 Stainless Stee
l
NEMA 4X
Fiberglass
Watertight, Dust-tight
Corrosion Resistant
NEMA 7 & 9
NEMA 3 & 4
Class I Groups C & D
Class II Groups E, F & G
Class III
Bolted Enclosures
Indoor/Outdoor Use
NEMA 12
NEMA 3/3R
b
Industrial Use
Weatherproof
Catalog No $ Catalog No $ Catalog No $ Catalog No $ Catalog No $ Catalog No $
1½ 1½ 2 2 9 00
14BP32A*81
14BP32B*81
Use Size 0
Use Size 0
Use Size 0
Use Size 0
3 3 5 5 18 0
14CP32A*81
14CP32B*81
14CP32@*81
14CP32F*81
14CP32H*81
14CP320*81
7½ 7½ 10 10 27 1
14DP32A*81
14DP32B*81
14DP32@*81
14DP32F*81
14DP32H*81
14DP320*81
10 10 15 15 40
1¾
14EP32A*81
14EP32B*81
14EP32@*81
14EP32F*81
14EP32H*81
14EP320*81
10 15 25 25 45 2
14FP32A*81
14FP32B*81
14FP32@*81
14FP32F*81
14FP32H*81
14FP320*81
15 20 30 30 60 2½
14GP32A*81
14GP32B*81
14GP32@*81
14GP32F*81
14GP32H*81
14GP320*81
25 30 50 50 90 3
14HP32A*81
14HP32B*81
14HP32@*81
14HP32F*81
14HP32H*81
14HP320*81
30 40 75 75 115 3½
14IP32A*81
14IP32B*81
14IP32@*81
14IP32F*81
14IP32H*81
14IP320*81
40 50 100 100 135 4
14JG32A*81
14JG32B*81
14JG32@*81
14JG32F*81
14JG32H*81
14JG320*81
Extra Wide Enclosure, 3-Phase, 3-Pole
a
Max Hp
Cont-
actor
Amp
Rating
NEMA
Size
Half
Size
Enclosure
200
Volts
230
Volts
460
Volts
575
Volts
NEMA 1
General Purpose
NEMA 4/4X Stainless
b
Watertight, Dust-tight
Corrosion Resistant
@ = W for 304 Stainless Steel
@ = X for 316 Stainless Steel
NEMA 7 & 9. NEMA 3 & 4
Div 1 and Div 2
Class II Groups E, F & G
Bolted Enclosures
NEMA 12. NEMA 3/3R
b
Industrial Use
Weatherproof
Class III
Catalog No Price $ Catalog No Price $ Catalog No Price $ Catalog No Price $
1½ 1½ 2 2 9 00
14BP82B*81
Use Size 0
Use Size 0
Use Size 0
3 3 5 5 18 0
14CP82B*81
14CP82@*81
14CP82H*81
14CP820*81
7½ 7½ 10 10 27 1
14DP82B*81
14DP82@*81
14DP82H*81
14DP820*81
10 10 15 15 40 1 3⁄4
14EP82B*81
14EP82@*81
14EP82H*81
14EP820*81
10 15 25 25 45 2
14FP82B*81
14FP82@*81
14FP82H*81
14FP820*81
15 20 30 30 60 2 1⁄2
14GP82B*81
14GP82@*81
14GP82H*81
14GP820*81
25 30 50 50 90 3
14HP82B*81
14HP82@*81
14HP82H*81
14HP820*81
30 40 75 75 115 3 1⁄2
14IP82B*81
14IP82@*81
14IP82H*81
14IP820*81
Open Type & Standard Width Enclosure, Single Phase, 2-Pole
c
Max Hp
Contactor
Amp
Rating
NEMA
Size
Half
Size
Enclosure
115
Volts
208/
230
Volts
Open Type
NEMA 1
General Purpose
NEMA 4/4X Stainless
b
Watertight, Dust-tight
Corrosion Resistant
@ = W for 304 Stainless Steel
@ = X for 316 Stainless Steel
NEMA 4X
Fiberglass
Watertight, Dust-tight
Corrosion Resistant
Class II Groups E, F & G
Class III
NEMA 7 & 9
NEMA 3 & 4
Div 1 and Div 2
Class I Groups C & D
Bolted Enclosures
NEMA 12
NEMA 3/3R
b
Industrial Use
Weatherproof
Catalog No $ Catalog No $ Catalog No $ Catalog No $ Catalog No $ Catalog No $
1
3 1 9 00
14BP12A*81 14BP12B*81 Use Size 0 Use Size 0 Use Size 0 Use Size 0
1 2 18 0
14CP12A*81 14CP12B*81 14CP12@*81 14CP12F*81 14CP12H*81 14CP120*81
2 3 27 1
14DP12A*81 14DP12B*81 14DP12@*81 14DP12F*81 14DP12H*81 14DP120*81
3 5 35 1P
14EP12A*81 14EP12B*81 14EP12@*81 14EP12F*81 14EP12H*81 14EP120*81
3 7½ 45 2
14FP12A*81 14FP12B*81 14FP12@*81 14FP12F*81 14FP12H*81 14FP120*81
5 10 60 21⁄2
14GP12A*81 14GP12B*81 14GP12@*81 14GP12F*81 14GP12H*81 14GP120*81
Heavy Duty Motor Starters
Ambient Compensated Bimetal Overload with Manual and Auto Reset, Class 14
Selection
Product Category: NEMA