User Manual

10
IT-RefeRence 20i OwneRs Manual
Specifications
AC Current Capacity:
Input - 20 Amp capacity required
Output - 12 - 20 Amp RMS * (maximum, all outlets combined - continuous)
* Due to the Power Factor Technology circuit, available RMS power varies with the reactance of the load (vector). However,
this only aects the circuit breaker for continuous RMS current draw. Since power ampliers will require high transient current
demands, the IT-Reference 20i will never succumb to current compression. Quite the opposite, in fact, it will buer the power
amplier’s power supply, while lowering the AC input impedance, allowing power ampliers to work more eciently.
Linear Noise Attenuation:
Transverse (Dierential) Mode
>20 dB from 1Khz. - 2 kHz.
>40 dB from 2Khz. - 100 kHz.
>80 dB from 100 kHz. – 1GHz.
Linear attenuation curve from 0.05 – 100 ohms line impedance
Common Mode
>95 dB, 10Hz. - 50 kHz.
>40 dB 50kHz. – 1MHz.
Outlets:
8 (symmetrical balanced outlets)
4 (Power Factor Technology outlets • 9 amps RMS reserve • resistive load • over 80 amps pk. charge)
Transient Voltage Surge Suppression:
120VAC Line
Virtually maintenance-free AC surge suppression
Non-sacricial with zero ground contamination
Telco - Cable / Satellite
Less than .1dB line loss
Dimensions:
5.75” H x 17 W x 15.625” D (standard 3RU without feet)
Weight:
83 lbs.
Power Consumption:
8.5 Watts for display and control circuits independent of actual load.
Safety Agency Listing:
ETL / C-ETL (Pending)