Operation Manual
Other features
52
Example for calling cycles and acoustic signals of pabx systems in DE, AT, BE, HU, PL, SL, GR
Acoustic sig
-
nals
Frequency (Hz).
Attenuation
(dB)
Cycle rate for sound / pauses in milliseconds
Dial tone 420 / -8 200, 300, 200, 300, 200, 800 ...
//___//___//________//___//___//________//___//___//________//___//___//________//___//___/
Busy tone 420 / -8 200, 400 ...
//____//____//____//____//____//____//____//____//____//____//____//____//____//____//____/
Ringing signal 420 / -8 1000, 4000 ...
//////////________________________________________//////////_______________________________
Call waiting to
-
ne
420 / -8 200, 300, 200, 1300 ...
//___//_____________//___//_____________//___//_____________//___//_____________//___//____
Ack. signal 320+420/ -8 700
///////
Neg. ac
-
knowledge
-
ment
320+420/ -8 300, 300, 300,300, 300
///___///__ _///
Setup example
Advanced Setting
ICMP Not Echo
•
Activating reply barring for a »Ping signal.
Send Anonymous CID
•
Activating number suppression.
Send Flash Event
•
Activating flash signaling as DTMF EVENT or as SIP INFO.