Datasheet
PABX functions III
Feature Description
Pickup Pickup of calls to other extensions: Pickup within a group; group assignment can be
programmed per extension.
Pickup specified Specified pickup by entering the extension call number; this covers all groups
Pickup of answering machine Pickup of a call that has already been answered from an answering machine
ISDN connectors
point-to-multipoint/point-to-point with
DDI (also mixed)
In the hybird both external point-to-points (P-P) as well as point-to-multipoints (P-MP) can be
set up.
Calendar (PBX Day/Night, CoS, door
intercom, teams) (1)
Time-dependent switches via the calendars for: 'Authorisation class', 'Night operation', 'Team
signalling', 'Door terminal signalling' and 'Release to internal/external call numbers'
Calendars (PBX Day/Night, CoS, door
terminal, teams) (2)
Several different switching times can be selected for each weekday. Exceptions for public
holidays can be configured
Changeable codes for important
functions
Programmable telephone codes: exchange access, pickup, specified pickup, speeddial
number, project number, bundle assignment, open hold for enquiry
Keypad procedures in exchange Control of performance features in the exchange, authorisation per extension in the CoS
Speeddial number Access to entries in the phone book via a code combined with the respective entry index
(000-999)
Layer 2 on exchange connector
switched to active non-stop
The ISDN Layer 2 is kept active non-stop. Can be configured per exchange connector
Brokering Any change between internal and external connections; the respective caller on hold hears
MoH.
Save message on SysTel Signalling via UUS 1
Name display in the call and in the
connection
During the call as well as during the connection, the caller's number is displayed (CLIP). If the
call number is entered in the phone book, the corresponding name is displayed.
Name assignment for connectors,
terminals and teams
In the configuration, names can be assigned to the individual ports. For internal calls the name
is displayed on the terminal. In addition the name is also visible in the PABX menu and in FCI,
as well as on the terminal for team calls.
Emergency functions with priority
circuit (blockade break for ISDN)
A terminal that is configured as an emergency telephone disconnects an occupied exchange
port if it is attempting to use an exchange. Any internal extensions can be configured as
emergency telephones.
Emergency number
storage/emergency telephone/alarm
point-to-point (1)
In the hybird, 10 emergency numbers (up to 20 digits) can be set up. The occupied ISDN
exchange is then subject to a blockade break if one of the saved emergency numbers is
dialled.
Emergency number
storage/emergency telephone/alarm
point-to-point (2)
The emergency number dial is, provided that all exchange lines (incl. SIP provider) are
occupied, always routed via ISDN (VoIP blocked).
Open hold for enquiry - park in system By using the open hold for enquiry function, the caller is held in the system queue. The call
can be transferred to any telephone via the code procedure or with SysTel park keys.
Funkwerk Enterprise Communications GmbH - Suedwestpark 94 - 90449 Nuremberg - Germany
Phone: +49 - (0)911 9673 0
Fax: +49 - (0)911 688 0725
E-Mail: info@funkwerk-ec.com - www.funkwerk-ec.com
hybird
11.03.2011
Subject to technical
alterations