Owner's manual

ffsstd-pds-2011-1222
Specifications
Models ICS/ICX/FB 4 6 9.5 10 15 20 25 30 50 60
Boiler Connections
N. Steam Outlet 15 PSI 1” 1” N/A 1.5” 2” 3” 3” 3” 4” 4”
25 NPT NPT NPT CL150# CL150# CL150# CL150# CL150#
Flange Flange Flange Flange Flange
N. Steam Outlet 150 PSI 0.75” 0.75” 1” 1” 1.25” 1.5” 2” 2” 3” 3”
19 NPT NPT NPT NPT NPT NPT NPT CL150# CL150#
Flange Flange
O. Safety Valve Outlet 15 PSI IN 0.75 0.75 N/A 0.75 1 1.5 1.5 1.5 2 2
MM 19 19 19 32 38 38 38 38 38
O. Safety Valve Outlet 150 PSI+ IN 1 1 1 1 1 1 1 1 1.25 1.25
(9.5 HP 100 PSI) MM 25 25 25 25 25 25 25 25 32 32
P. Safety Valve Inlet 15 PSI++ IN 0.75 0.75 N/A 0.75 1 1.25 1.25 1.25 1.5 2
MM 19 19 19 25 32 32 32 32 32
P. Safety Valve Inlet 150 PSI IN 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1 1
(9.5 HP 100 PSI) MM 19 19 19 19 19 19 19 19 25 25
Q. Feedwater Inlet IN 0.75 0.75 1 1 1 1 1 1 1 1
MM 19 19 25 25 25 25 25 25 25 25
R. Blowdown Outlet IN 1 1 1 1 1 1.25 1.25 1.25 1.5 1.5
MM 25 25 25 25 25 32 32 32 38 38
S. Water Column Blowdown IN 1 1 1 1 1 1 1 1 1 1
MM 25 25 25 25 25 25 25 25 25 25
Ratings* (Sea level to 3000 ft.)
Output 1000 BTU/HR 134.40 201 318 335 503 670 838 1005 1674 2009
1000 KCAL/HR 33.8 50.7 80.1 84.4 127 169 211 253 422 506
Steam Output LB/HR 138 207 328 345 518 690 863 1035 1725 2070
KG/HR 63 94 149 157 235 313 392 470 785 942
Approximate Fuel Consumption at Rated Capacity+++
Light Oil GPH 1.2 1.8 2.8 3.0 4.5 6.0 7.5 9.0 15.0 17.9
LPH 4.5 6.8 10.6 11.4 17 22.7 28.4 34.1 56.8 67.8
Propane Gas (ICS) FT3/HR 67.2 100 159 168 251 335 419 502 837 1004
(14” w.c. req’d) M3/HR 1.9 2.8 4.5 4.8 7.1 9.5 11.9 14.2 23.7 28.4
Propane Gas (ICX) FT3/HR 63 97 161 242 323 404 484
(14” w.c. req’d) M3/HR 2.2 2.7 N/A 4.6 6.9 9.1 11.4 13.7
Natural Gas (ICS) FT3/HR 168 257 398 419 628 837 1047 1256 2093 2511
(7” - 11” w.c. req’d) M3/HR 4.8 7.1 11.3 11.9 17.8 23.7 29.7 35.4 59.3 71.1
Natural Gas (ICX) FT3/HR 159 242 384 403 606 807 1009 1210
(7” - 11” w.c. req’d) M3/HR 5.6 6.9 10.8 11.4 17.2 22.9 28.6 34.3
Natural Gas Boiler IN 1 1 1 1 1 1.25 1.25 1.5 1.5 2
Connection Size (Std CSD-1) MM 25 25 25 25 25 32 32 38 38 51
Oil Inlet Size IN 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4
MM 6 6 6 6 6 6 6 6 6 6
Burner 3450 RPM/60 CY 1/3 gas 1/3 gas 1.5 gas 1.5 gas
Motor HP 2850 RPM/50 CY 1/3 1/3 1/3 1/3 1/3 3/4 oil 3/4 oil 3/4 2 oil 2 oil
Electric Power Requirements - Burner Only (in Amps) ***
120V,60 CY, 1 Phase 5.2 5.2 5.2 5.2 5.2 5.2 gas 5.2 gas 9.2 -- --
9.2 oil 9.2 oil
240V, 50/60 CY, 1 Phase 2.6 2.6 2.6 2.6 2.6 2.6 gas 2.6 gas 4.6 8.9 gas 8.9 gas
4.6 oil 4.6 oil 9.5 oil 9.5 oil
208V, 50/60 CY, 3 Phase 1.9 1.9 1.9 1.9 1.9 1.9 gas 1.9 gas 3.1 4.4 gas 4.4 gas
3.1 oil 3.1 oil 5.7 oil 57 oil
240V, 50/60 CY, 3 Phase 1.6 1.6 1.6 1.6 1.6 1.6 gas 1.6 gas 2.8 4.2 gas 4.2 gas
2.8 oil 2.8 oil 5.4 oil 5.4 oil
480V, 50/60 CY, 3 Phase 0.8 0.8 0.8 0.8 0.8 0.8 gas 0.8 gas 1.4 2.1 gas 2.1 gas
1 .4 oil 1.4 oil 2.7 oil 2.7 oil
Water Content
U.S. GAL 14 16 16 24 39 77 82 170 245 270
LITERS 53 61 61 91 148 292 310 644 927 1022
Specifications and Dimensions are approximate. We reserve the right to change specifications and/or dimensions..+ High pressure boilers purchased with low pressure
openings may have larger than specified opening sizes, consult factory for correct opening sizes.++ 50 and 60 HP have two safety valves on low pressure.
+++Consumption based on light Oil 140,000 BTU/G; Natural Gas 1000 BTU/ft.
3
; Propane 2500 BTU/ft
3
. *All ratings from 0 PSIG and at 212 degrees F. *** Control
circuit electrical requirement will vary with the system voltage, please consult factory. --Consult factory.