Installation

EN
19
Proper adjustment will produce a stable, steady blue fl ame of
minimum size.
The fi nal adjustment should be checked by turning the knob
from high to low several times without extinguishing the fl ame.
This adjustment, at low setting, will automatically provide the
proper fl ame size at medium setting.
After Conversion steps have been completed, check the
appearance of each burner’s fl ame at the HI and LO settings,
if the fl ames appear too large or too small
review each step to make sure it was completed correctly.
NOTE: To obtain the correct minimum setting with LP gas,
turn clockwise tightening the valve(s) fully with the thin-blade
screwdriver into the recess behind control knob (A and / or B).
Electric Gas Ignition
The gas burners use an electric ignition device located near
each burner ensures burners ignite automatically.
ELECTRIC IGNITION
See Use & Care manual for better explanation and its control.
The Burner Flames
Turn each burner on. Flames should be blue in color with no
trace of yellow. The burner fl ames should not fl utter or blow
away from the burner The inner cone of the fl ame should be
between 1/2” and 3/4” long.
BURNER FLAMES
1/2” to 3/4”
BURNER
6 - Conversion for LP or NG Gas