Installation Manual
EN
23
7.2 Mounting the handles on stainless front
NOTE
To mount the handles onto the door and the drawer 
operate as follows:
Operate as follows:
•  Insert the handle ends onto the supports already installed 
on the door and the drawer [ 1 ].
1
•  Screw in the Allen screws available on the handle [ 2 ].
2
The screws must be tightened in by means of a 2.5 mm 
(1/8”) hex wrench.
7.3 Ventilation
Professional Built-In Series
A forced air system assures ventilation through a grille 
positioned in the lower front part of the unit. If the kitchen 
design includes a kickplate, the latter has to be entirely in 
order to maintain a satisfactory air flow, as described in the 
drawing. 
Holes can be in any shape and size, as long as the total 
area of the area equals 50% of the kickplate area. 
In this case, to guarantee a better air flow, it is advisable 
to remove the front grille included with the unit. The grille 
is secured to the unit with magnetic plates and can be 
easily removed even by the end user, to provide for regular 
cleaning procedures and dust removal.
If the grille is partially covered by the kitchen kickplate, it 
is advisable to remove the grille in order to provide for a 
better airflow.
A
B
C
C
SERIES 36” SERIES 24”
A
860 (33 7/8”) 560 (22”)
B
> 100 (4”)
C
10 (3/8”)
The air intake and outlet must not be blocked or covered 
entirely. The condenser must to be dusted/cleaned on a 
regular basis.