Installation Manual

EN
7
CAUTION
• Do not repair or replace any part of the appliance
unless specifically recommended in the manual. All other
servicing should be done by a qualified technician. This
may reduce the risk of personal injury and damage to
the oven.
• Never modify or alter the construction of the appliance by
removing panels, wire covers, screws, or any other part
of the product.
Electrical Connections
Be sure your appliance is properly installed and grounded by
a qualied technician. Ask your dealer to recommend a qualied
technicianoranauthorizedrepairservice.
This appliance is manufactured with a green GROUND wire
connected to the oven chassis. After making sure that the
power has been turned o, connect the exible conduit from the
oven to the junction box using a U.L. listed conduit connector.
Figures A and B and the instructions provided below present
the most common way of connecting the ovens.
Your local codes and ordinances, of course, take precedence
over these instructions. Complete electrical connections
accordingtolocalcodesandordinances“WARNING”Riskof
Electric Shock, frame grounded to neutral of appliance through
a link .
Grounding through the neutral conductor is prohibited for new
branch-circuit installations (1996 NEC); mobile homes; and
recreational vehicles, or in an area where local codes prohibit
grounding through the neutral conductor. For installations
where grounding through the neutral conductor is prohibited:
• Disconnect the ground from the neutral at free end of
conduit;
• Usegroundingterminalorleadtogroundunit;and
• Connect neutral terminal or lead to branch circuit neutral in
usual manner.
3-Wire Branch Circuit (For Us Only)
Refer to Figure A, where local codes allow the connection of
GROUND wire from the oven to the branch circuit NEUTRAL
wire(grayorwhitecoloredwire):
• If local codes permit, connect the green GROUND wire
from the oven and the white wire from the oven to the
branchcircuitNEUTRALwire(grayorwhitecoloredwire).
• Connect the red and black leads from the oven to the
corresponding HOT Wires in the junction box.
• Connect the local codes and power supply codes using a
terminal.
• The terminal uses a thing adapting to the wire of the cord.
GROUNDED NEUTRAL
White wires
Cable from
power supply
Junction box
UL listed conduit
connector
Red wires
Black wires
Cable
from oven
Bare or
green wire
A