Use and Care
Use & Care Manual
ENGLISH
6
Models and Part Identification
1.DOUBLECROWNS(700to18000Btu/hburner&control
knob)
2.SR(1,300to6,300Btu/hburner&controlknob)
3.R(2,200to12,000Btu/hburner&controlknob)
4.AUX(1,000to4,000Btu/hburner&controlknob)
1.SR(1,300to6,300Btu/hburner&controlknob)
2.SR(1,300to9,000Btu/hburner&controlknob)
3.DOUBLECROWNS(700to18000Btu/hburner&control
knob)
4.R(2,200to12,000Btu/hburner&controlknob)
5.AUX(1,000to4,000Btu/hburner&controlknob)
A.Grates
B.BurnerCup
C.BurnersGasSpreader
1.DOUBLECROWNS(700to18000Btu/hburner&control
knob)
2.AUX(1,000to4,000Btu/hburner&controlknob)
3.R(2,200to12,000Btu/hburner&controlknob)
4.SR(1,300to9,000Btu/hburner&controlknob)
5.SR(1,300to6,300Btu/hburner&controlknob)
1.DOUBLECROWNS(700to18000Btu/hburner&control
knob)
2.AUX(1,000to4,000Btu/hburner&controlknob)
3.SR(1,300to9,000Btu/hburner&controlknob)
4.R(2,700to15,000Btu/hburner&controlknob)
3 4
1
2
5
3 2
1
4 5
A
5
4
1
2
3
3 2
1
4 5
A
1 4 3 2
1
2 3 4
A
3
2
1 4
3 2
1
4
A
B
C
24” 30”
42”36”
Applianceinstalledover2,000feet(610mt)De-rateeffect
Cooktop
Nominal values
Btu/h from
0 to 2,000 (610)
Elevation
from 2,000 (610)
to 4,000 (1220)
Elevation
from 4,000 (1220)
to 6,000 (1829)
Elevation
from 6,000 (1829)
to 8,000 (2438)
Elevation
from 8,000 (2438)
to 10,000 (3048)
24”4burners 40,300 37,076 34,109 31,381 28,870
30”5burners 49,300 45,264 41,643 38,311 35,246
36”5burners 49,300 45,264 41,643 38,311 35,246
42”4burners 46,000 42,320 38,934 35,820 32,954
(De-rated 4% per 1000 feet)