Data Sheet

Data Sheet Fujitsu PRIMERGY TX200 S6 Server
Page 6 / 9 http://ts.fujitsu.com/Primergy
Server Management
Option ServerView Integration for Tivoli TEC®, Tivoli NetView, HP NNM and HP Operations Manager
iRMC S2 Advanced Pack
Server Management notes Regarding Operating System dependencies and product details for ServerView Suite Software Products see dedicated
Product Data sheets.
Dimensions / Weight
Floor-stand (W x D x H) 205 (306 ) x 584 x 444 mm
Rack (W x D x H) 482 x 570 x 220 mm
Dimension notes Floorstand Width 306 mm with tilt protection; depth measured excludes handles on redundant PSU. Rack depth
excludes handles of redundant PSU and rack front.
Mounting Depth Rack 596 mm
Height Unit Rack 5 U
Weight up to 36,8 kg
Weight notes Actual weight may vary depending on conguration
Rack integration kit Rack integration kit as option
Environmental
Noise emission Measured according to ISO 7779 and declared according to ISO 9296
Sound pressure (LpAm) 34 dB(A) (idle) / 36 dB(A) (operating)
Sound power (LWAd; 1B = 10dB) 5.2 B (idle) / 5.7 B (operating)
Noise notes / description measured with standard fans and PSU
Operating ambient temperature 10 - 35C
Operating relative humidity 10 - 85 % (non condensing)
Operating environment FTS 04230 Guideline for Data Center (installation locations)
Operating environment Link http://docs.ts.fujitsu.com/dl.aspx?id=e4813edf-4a27-461a-8184-983092c12dbe
Electrical values
Power supply conguration 1x standard, 1x hot-plug or 2x redundant
Max. output of single power supply 685 W
Standard power supply output 700 W (85% efciency)
Hot-plug power supply output 800 W (92% efciency)
Hot-plug power supply redundancy Yes
Rated voltage range 100 V - 240 V
Rated frequency range 47 Hz - 63 Hz
Rated current max. 9.5 - 4.0A
Rated current in basic conguration 1,3 0.6A
Active power (min. conguration) 111 W
Active power (max. conguration) 461 W
Apparent power (max. conguration) 490 VA
Heat emission 1659.6 kJ/h (1573.0 BTU/h)
Power Supply Notes In case of using an UPS we recommend to select a 1500VA/1000 W type as a minimum, because high power peaks
might be possible when switching over to battery!
The following Energy Star Familiy conguration options use less energy and reduce greenhouse gas emissions:
TX200 S6 E-StarFam1
http://ts.fujitsu.com/products/standard_servers/e_efcient.html
Compliance
Germany TÜV GS
Europe CE Class A *
USA/Canada CSAc/us
ULc/us
FCC Class A
Global CB
RoHS (Restriction of hazardous substances)
WEEE (Waste electrical and electronical equipment)
Japan VCCI Class A + JIS 61000-3-2