Datasheet

Data Sheet FUJITSU Server PRIMERGY TX150 S8 Mono-Socket Intel® Xeon® processor server
Page 6 / 10 www.fujitsu.com/fts
Server Management
Standard ServerView Suite - Deploy
SV Installation Manager
SV Scripting Toolkit
ServerView Suite - Control
Operations Manager incl. PDA and ASR & R
(Prefailure and Analysis; Automatic Server Recovery and Restart)
Agents and CIM Providers
System Monitor
RAID Manager
Capacity Management
Power Management
Storage Support
ServerView Suite - Maintain
Remote Management (iRMC)
Update Management (BIOS, Firmware, Windows Drives and SV Agents)
Performance Measurement
Asset Management
Online Diagnostics
ServerView Suite - Integrate
Integration packs e.g. for Microsoft System Center, VMware vCenter, Nagios, HP SIM and others
Deployment Solutions and others
Option ServerView Suite - Maintain
iRMC Advanced Pack incl. Advanced Video Redirection (AVR), video capturing and Virtual Media
ServerView Suite - Dynamize
Virtual-IO Manager (VIOM)
Resource Orchestrator Virtual Edition (ROR VE)
Resource Orchestrator Cloud Edition (ROR CE)
ServerView Suite - Integrate
Integration pack for Fujitsu ManageNow® solution
Server Management notes Regarding dependencies for ServerView Suite software products see dedicated product data sheets.
Dimensions / Weight
Floor-stand (W x D x H) 177 x 651 x 456 mm
Rack (W x D x H) 483 x 611 x 177 mm
Dimension notes Floorstand Width 177 mm without tilt protection (420 mm with tilt protection); depth measured includes handles on
redundant PSU. Rack depth includes handles of redundant PSU, excludes rack handles / front.
Height Unit Rack 4 U
Weight 16 - 29 kg
Weight notes Actual weight may vary depending on conguration
Rack integration kit Rack integration kit as option
Dimensions / Weight / Environmental
(Base unit specic)
Environmental
Operating ambient temperature 10 - 35 °C
Operating relative humidity 10 - 85 % (non condensing)
Operating environment FTS 04230 – Guideline for Data Center (installation specication)
Operating environment link http://docs.ts.fujitsu.com/dl.aspx?id=e4813edf-4a27-461a-8184-983092c12dbe
Noise emission Measured according to ISO 7779 and declared according to ISO 9296
Sound pressure (LpAm) 22 dB(A) idle mode/ 22 dB(A) operation mode with low noise mode; 30 dB(A) idle mode/ 30 dB(A) operation mode
with SAS HDDs; 36 dB(A) idle mode/ 36 dB(A) operation mode with HDD extension boxes;
Sound power (LWAd; 1B = 10dB) 4.0 B idle / 4.0 B operation mode with low noise mode; 4.8 B idle mode/ 4.8 B operation mode with SAS HDDs; 5.4 B
idle mode/ 5.4 B operation mode with HDD extension boxes;
Noise notes Noise emissions and operation modes depend on system conguration.
Availability of the low noise mode depends on system conguration. To order an eligible system use the checkbox
“Enabling low noise mode” in System Architect.
Electrical values
Power supply conguration 1 x standard power supply or1 x hot-plug power supply or 2 x hot-plug power supply for redundancy depending on
model