Datasheet
DATASHEET PRIMERGY TX120 S2
3 / 4
SUPPORTED OPERATING SYSTEMS
Operating system release link http://ts.fujitsu.com/software
http://docs.ts.fujitsu.com/dl.aspx?id=a9e600b9-e4cb-4f48-aa41-632f69058421
SERVER MANAGEMENT
Standard PDA Prefailure Detection and Anaylsis
ASR&R Automatic Server Recovery and Restart
ServerView Suite:
SV Installation Manager
SV Operation Manager
SV RAID Manager
SV Update Management
SV Power Management
SV Agents
Online update packages for BIOS, rmware drivers and ServerView Agents
ServerView Integration solutions for Microsoft SMS, MOM, SCOM, SCCM and Altiris
Deployment Solution ServerView Deployment Manager (fully functional 30-day trial version)
ServerView Integration solutions for Microsoft SMS, MOM, SCOM, SCCM and Altiris Deployment Solution
ServerView Deployment Manager (fully functional 30-day trial version)
ServerView Remote Management (iRMC)
Option ServerView Integration for Tivoli TEC
®
, Tivoli NetView, HP NNM and HP Operations Manager
iRMC Advanced Pack
Deployment Solution ServerView Deployment Manager
Server Management notes Regarding Operating System dependencies and product details for ServerView Suite Software Products see
dedicated Product Data sheets.
DIMENSIONS / WEIGHT
Floor-stand (W x D x H) 99 x 399 x 340 mm
Dimension notes without feet
Weight up to 10 kg
Weight notes Actual weight may vary depending on conguration
ENVIRONMENTAL
Noise emission Measured according to ISO 7779 and declared according to ISO 9296
Sound pressure (LpAm) 27 dB(A) (idle) / 32 dB(A) (operating)
Sound power (LWAd; 1B = 10dB) 4,3 B (idle) / 4.7 B (operating)
Operating ambient temperature 10 - 35°C
Operating relative humidity 10 - 85 % (non condensing)
ELECTRICAL VALUES
Power supply conguration 1x standard power supply
Standard power supply output 300 W
Rated voltage range 100 - 240 V
Rated frequency range 50 - 60 Hz
Rated current max. 2.7 A / 1.1A (100 V / 240 V)
Active power max. (per system unit) 120 W
Apparent power max. (per system
unit)
56-127 VA
Heat emission 432.0 kJ/h (409.6 BTU)
COMPLIANCE
Germany GS
Europe CE
USA/Canada CSAc/us
ULc/us
FCC Class A
Global CB
RoHS (Restriction of hazardous substances)
WEEE (Waste electrical and electronical equipment)
Compliance notes There is general compliance with the safety requirements of all European countries and North America. National
approvals required in order to satisfy statutory regulations or for other reasons can be applied for on request.
Compliance link https://sp.ts.fujitsu.com/sites/certicates/default.aspx