Dimensions / Weight
Rack (W x D x H) 482.6 mm (Bezel) / 448 mm (Body) x 736 x 177 mm
Mounting Depth Rack 700 mm
Height Unit Rack 4 U
19” rackmount Yes
Weight up to 35 kg
Weight notes Actual weight may vary depending on conguration
Rack integration kit Rack integration kit as option
Environmental
Operating ambient temperature 10 - 35 °C
Operating relative humidity 10 - 85 % (non condensing)
Operating environment FTS 04230 – Guideline for Data Center (installation specication)
Operating environment Link http://docs.ts.fujitsu.com/dl.aspx?id=e4813edf-4a27-461a-8184-983092c12dbe
Noise emission Measured according to ISO 7779 and declared according to ISO 9296
Sound pressure (LpAm) Minimum noise : 33 dB(A) (idle) / 33 dB(A) (operating)
Typical noise : 38 dB(A) (idle) / 38 dB(A) (operating)
Sound power (LWAd; 1B = 10dB) Minimum noise : 5,1 B (idle) / 5,1 B (operating)
Typical noise : 5,6 B (idle) / 5,6 B (operating)
Noise notes Noise emissions and operation modes depend on system conguration.
Electrical values
Power supply conguration 1-4x 450 W / 800 W hot-plug power supply
Max. output of single power supply 450 W (94 % efciency); 800 W (94 % / 96 % efciency)
Power supply efciency 94 % (80 PLUS platinum)
96 % (80 PLUS titanium) (planned)
Hot-plug power supply output 450 W (94 % efciency); 800 W (94 % / 96 % efciency)
Hot-plug power supply redundancy Yes
Rated voltage range 100 V - 240 V
Rated frequency range 47 Hz - 63 Hz
Rated current in basic conguration 100 V - 240 V / TBD
Active power (max. conguration) 1070 W
Active power note To estimate the power consumption of different congurations use the Power Calculator of the System Architect:
http://congurator.ts.fujitsu.com/public/
Apparent power (max. conguration) 1080 VA
Heat emission 3852.0 kJ/h (3651.0 BTU/h)
Power Supply Notes Power Safeguard adapts system performance in case the wattage exceeds supply limits.
Compliance
Germany GS
Europe CE Class A *
USA/Canada CSAc/us
FCC Class A
Global CB
RoHS (Restriction of hazardous substances)
WEEE (Waste electrical and electronical equipment)
Japan VCCI
China CCC (planned)
Australia/New Zealand C-Tick
Taiwan CNS 13438 class A - planned
Compliance notes There is general compliance with the safety requirements of all European countries and North America. National
approvals required in order to satisfy statutory regulations or for other reasons can be applied for on request.
* Warning:
This is a class A product. In a domestic environment this product may cause radio interference in which case the user
may be required to take adequate measures.
Compliance link http://globalsp.ts.fujitsu.com/sites/certicates