Datasheet

Data Sheet FUJITSU Server PRIMERGY RX350 S8 Dual Socket 4U rack server
Page 4 / 9 www.fujitsu.com/fts
Interfaces
Graphics (15-pin) 2 x VGA (thereof 1x front optional)
Serial 1 (9-pin) 1 x serial RS-232-C, usable for iRMC or system or shared
LAN / Ethernet 2 x Gbit/s Ethernet (RJ45) with upgrade options for additional 2x1 Gbit/s (RJ45), 4x 1 Gbit/s (RJ45) or 2x 10 Gbit/s (SFP+)
Management LAN (RJ45) 1 x dedicated management LAN port for iRMC S4 (10/100/1000 Mbit/s)
Management LAN trafc can be switched to shared onboard Gbit LAN port
or optional Modular LAN 2x10 Gbit controller
Front Service LAN port as option
Onboard or integrated Controller
RAID controller 4 port for internal 3G SATA and SAS (as upgrade option with SAS enabling key) for HDDs with RAID 0/1/10 or SAS LTO
device (Intel C600)
additional RAID controller options are described under Components RAID controller
SATA Controller Intel® C600, 2 x SATA channel for ODD
LAN Controller Intel® Ethernet Controller I350. 2 x 10/100/1000 Mbit/s Ethernet (I/O acceleration). Modular integrated on-board LAN
offers upgrade options for additional 2x1 Gbit/s , 4x 1 Gbit/s or 2x 10 Gbit/s.
PXE-Boot via LAN from PXE server, iSCSI boot (also diskless)
Remote management controller Integrated Remote Management Controller (iRMC S4, 256 MB attached memory incl. graphics controller)
IPMI 2.0 compatible
GPU / coprocessor 1-2 NVIDIA® Tesla™ K20 and K20X GPGPU
1-2 Intel® Xeon® Phi 3120P / 5110P / 7120P coprocessor
Trusted Platform Module (TPM) Inneon / separate module; TCG V1.2 compliant (option)
Slots
PCI-Express 3.0 x4 (mech. x8) 2 x Full height (2nd processor required)
PCI-Express 3.0 x8 4 x Full height (here of 1 is reserved for Modular RAID controller)
PCI-Express 3.0 x8 (mech. x16) 1 x Full height
PCI-Express 3.0 x16 2 x Full height (2nd processor required)
PCI-Express 2.0 x4 (mech. x8) 1 x Full height (2nd processor required)
Slot Notes One PCIe Gen3 x8 slot may be occupied with a Modular integrated on-board LAN controller if congured.
One PCIe Gen3 x8 slot may be occupied with a modular RAID controller if congured.
Important: 5 PCIe slots are supported with the rst processor. 10 PCIe slots are supported with two processors.
Possible slot length described in relevant system ongurator.
Drive bays
Storage drive bays 2.5-inch or 3.5-inch hot-plug SAS/SATA
Accessible drive bays 1 x 5.25/0.5-inch for ODD
1 x 5.25/1.6-inch for ODD or backup devices
1 x 5.25/0.5-inch for Local Service Display
Notes accessible drives All possible options described in relevant system congurator.
Drive bays
Storage drive bays Max 12 (4 + 4 + 4) x 3.5-inch Max 24 (8 + 8 + 8) x 2.5-inch
Optional accessible drives 3x 5.25/1.6-inch bay for accessible devices (HDD: 4x 3.5-
inch hot-plug SAS/SATA or LTO drive)
3x 5.25/1.6-inch bay for accessible devices (HDD: 8x 2.5-
inch hot-plug SAS/SATA and LTO drive)
General system information
Number of fans 4
Fan conguration 4x single hot plug fans Ø90mm plus optional 2x single hot plug fans Ø90mm for redundancy
Operating panel
Operating buttons On/off switch
Reset button
NMI button