Design Technical Manual
Table Of Contents
- CHAPTER00
- CHAPTER01_General_information
- CHAPTER02_Model_selection
- 1. MODEL SELECTION PROCEDURE
- 2. MODEL LINE UP
- 3. MODEL SELECTION AND CAPACITY CALCULATION
- 4. CAPACITY TABLE COOLING (OUTDOOR UNIT)
- 5. CAPACITY TABLE HEATING (OUTDOOR UNIT)
- 6. CAPACITY COMPENSATION COEFFICIENT
- 7. CAPACITY TABLE COOLING (INDOOR UNIT)
- 7-1. COMPACT CASSETTE TYPE
- 7-2. CIRCULAR FLOW CASSETTE TYPE
- 7-3. CASSETTE TYPE
- 7-4. MINI DUCT TYPE
- 7-5. SLIM DUCT / SLIM CONCEALED FLOOR TYPE
- 7-6. MEDIUM STATIC PRESSURE DUCT TYPE
- 7-7. HIGH STATIC PRESSURE DUCT TYPE
- 7-8. VERTICAL AIR HANDLER TYPE
- 7-9. COMPACT FLOOR TYPE
- 7-10. FLOOR / CEILING TYPE
- 7-11. CEILING TYPE
- 7-12. WALL MOUNTED TYPE
- 8. CAPACITY TABLE HEATING (INDOOR UNIT)
- 8-1. COMPACT CASSETTE TYPE
- 8-2. CIRCULAR FLOW CASSETTE TYPE
- 8-3. CASSETTE TYPE
- 8-4. MINI DUCT TYPE
- 8-5. SLIM DUCT / SLIM CONCEALED FLOOR TYPE
- 8-6. MEDIUM STATIC PRESSURE DUCT TYPE
- 8-7. HIGH STATIC PRESSURE DUCT TYPE
- 8-8. VERTICAL AIR HANDLER TYPE
- 8-9. COMPACT FLOOR TYPE
- 8-10. FLOOR / CEILING TYPE
- 8-11. CEILING TYPE
- 8-12. WALL MOUNTED TYPE
- CHAPTER03_Outdoor_units
- CHAPTER04_Indoor_units
- CHAPTER05_Control_system
- 1. CONTROL SYSTEM
- 2. CONTROL UNITS
- 2-1. SYSTEM CONTROLLER
- 2-2. SYSTEM CONTROLLER LITE
- 2-3. TOUCH PANEL CONTROLLER
- 2-4. CENTRAL REMOTE CONTROLLER
- 2-5. WIRED REMOTE CONTROLLER (Touch panel)
- 2-6. WIRED REMOTE CONTROLLER
- 2-7. SIMPLE REMOTE CONTROLLER (With Operation mode)
- 2-8. SIMPLE REMOTE CONTROLLER (Without Operation mode)
- 2-9. WIRELESS REMOTE CONTROLLER
- 2-10. IR RECEIVER UNIT (for ALL DUCT TYPE)
- 2-11. IR RECEIVER UNIT (for CASSETTE TYPE)
- 2-12. IR RECEIVER UNIT (for CIRCULAR FLOW CASSETTE TYPE)
- 2-13. HUMAN SENSOR KIT (for CIRCULAR FLOW CASSETTE TYPE)
- 2-14. REMOTE SENSOR UNIT
- 2-15. PRESSURE SENSOR KIT
- 2-16. GROUP CONTROL METHOD
- 2-17. COMPARISON TABLE OF CONTROLLERS
- 3. ADAPTOR / CONVERTOR UNITS
- 4. SERVICE & WEB MONITORING TOOL
- CHAPTER06_System_design
- CHAPTER07_Function_setting
- CHAPTER08_External_input_and_output
- CHAPTER09_Notes
- CHAPTER10_Optional_parts
- CHAPTER99
1-1-4. OUTDOOR UNIT EXTERNAL INPUT / OUTPUT
FUNCTION SUMMARY
OUTDOOR UNIT EXTERNAL INPUT FUNCTION
Item
Dry contact /
Apply voltage
Function Specications
Emergency
stop
Low noise
mode
operation
Cooling/
Heating
priority
Outdoor
unit
operation
peak
control
Batch stop
Power
usage
information
from
electricity
meter
Terminal
Signal
type
Outdoor unit
input function
specication
Dry contact
DC12[V]
-
●
*2 - - - -
CN 131
(PIN 1-2)
Edge
- -
●
- - -
CN 132
(PIN 1-2)
- - -
●
*1 - -
CN 133
(PIN 1-2)
●
(20 - 01) - - -
●
(20-00) -
CN 134
(PIN 1-2)
- - - - - -
●
CN 135
(PIN 1-2)
Pulse
*1 : If you use Outdoor unit operation peak control, select energy saving level from below.
30-00 Energy saving level 1 (Stop)
30-01 Energy saving level 2 (Operated at 40% capacity)
30-02 Energy saving level 3 (Operated at 60% capacity)
30-03 Energy saving level 4 (Operated at 80% capacity)
30-03 Energy saving level 5 (Operated at 100% capacity)
*2 : If you use Low noise mode operation, select low noise level from below.
42-00 Low noise level 1 (lower than rated value)
42-01 Low noise level 2 (lower than level 1)
NOTES :
● For selecting relay, minimum permissible load must be less than 1 (mA).
● When you use Apply voltage, Take "+" polarity for PIN 1
● Number inside bracket "()" indicates function number and setting number.
● Expression "
●
" is equipping function.
OUTDOOR UNIT EXTERNAL OUTPUT FUNCTION
Item
Dry contact /
Apply voltage
Function Specications
Operation
status
Error
status
Base
heater
Terminal
Terminal
output
voltage
External power supply
Allowable
voltage
Allowable
current
Outdoor unit
output function
specication
Apply voltage
-
●
- CN 136 (PIN 1-2)
-
DC12-24
[V]
30 mA or
less
●
- - CN 137 (PIN 1-2)
Dry contact - -
●
CN 115 (PIN 1-3) AC240 [V] - 1 A or less
NOTES :
● When you use Apply voltage, Take "+" porarity for PIN 1
● Expression "●" is equipping function.
- (08 - 07) -
EXTERNAL INPUT
& OUTPUT
EXTERNAL INPUT
& OUTPUT