Design Technical Manual
Table Of Contents
- CHAPTER00
- CHAPTER01_General_information
- CHAPTER02_Model_selection
- 1. MODEL SELECTION PROCEDURE
- 2. MODEL LINE UP
- 3. MODEL SELECTION AND CAPACITY CALCULATION
- 4. CAPACITY TABLE COOLING (OUTDOOR UNIT)
- 5. CAPACITY TABLE HEATING (OUTDOOR UNIT)
- 6. CAPACITY COMPENSATION COEFFICIENT
- 7. CAPACITY TABLE COOLING (INDOOR UNIT)
- 7-1. COMPACT CASSETTE TYPE
- 7-2. CIRCULAR FLOW CASSETTE TYPE
- 7-3. CASSETTE TYPE
- 7-4. MINI DUCT TYPE
- 7-5. SLIM DUCT / SLIM CONCEALED FLOOR TYPE
- 7-6. MEDIUM STATIC PRESSURE DUCT TYPE
- 7-7. HIGH STATIC PRESSURE DUCT TYPE
- 7-8. VERTICAL AIR HANDLER TYPE
- 7-9. COMPACT FLOOR TYPE
- 7-10. FLOOR / CEILING TYPE
- 7-11. CEILING TYPE
- 7-12. WALL MOUNTED TYPE
- 8. CAPACITY TABLE HEATING (INDOOR UNIT)
- 8-1. COMPACT CASSETTE TYPE
- 8-2. CIRCULAR FLOW CASSETTE TYPE
- 8-3. CASSETTE TYPE
- 8-4. MINI DUCT TYPE
- 8-5. SLIM DUCT / SLIM CONCEALED FLOOR TYPE
- 8-6. MEDIUM STATIC PRESSURE DUCT TYPE
- 8-7. HIGH STATIC PRESSURE DUCT TYPE
- 8-8. VERTICAL AIR HANDLER TYPE
- 8-9. COMPACT FLOOR TYPE
- 8-10. FLOOR / CEILING TYPE
- 8-11. CEILING TYPE
- 8-12. WALL MOUNTED TYPE
- CHAPTER03_Outdoor_units
- CHAPTER04_Indoor_units
- CHAPTER05_Control_system
- 1. CONTROL SYSTEM
- 2. CONTROL UNITS
- 2-1. SYSTEM CONTROLLER
- 2-2. SYSTEM CONTROLLER LITE
- 2-3. TOUCH PANEL CONTROLLER
- 2-4. CENTRAL REMOTE CONTROLLER
- 2-5. WIRED REMOTE CONTROLLER (Touch panel)
- 2-6. WIRED REMOTE CONTROLLER
- 2-7. SIMPLE REMOTE CONTROLLER (With Operation mode)
- 2-8. SIMPLE REMOTE CONTROLLER (Without Operation mode)
- 2-9. WIRELESS REMOTE CONTROLLER
- 2-10. IR RECEIVER UNIT (for ALL DUCT TYPE)
- 2-11. IR RECEIVER UNIT (for CASSETTE TYPE)
- 2-12. IR RECEIVER UNIT (for CIRCULAR FLOW CASSETTE TYPE)
- 2-13. HUMAN SENSOR KIT (for CIRCULAR FLOW CASSETTE TYPE)
- 2-14. REMOTE SENSOR UNIT
- 2-15. PRESSURE SENSOR KIT
- 2-16. GROUP CONTROL METHOD
- 2-17. COMPARISON TABLE OF CONTROLLERS
- 3. ADAPTOR / CONVERTOR UNITS
- 4. SERVICE & WEB MONITORING TOOL
- CHAPTER06_System_design
- CHAPTER07_Function_setting
- CHAPTER08_External_input_and_output
- CHAPTER09_Notes
- CHAPTER10_Optional_parts
- CHAPTER99
LINE UP (3/3)
Capacity
Wall mounted
Btu/h
Model
code
4,000 4
7,50 0 7
9,500 9
12,000 12
14,000 14
18,000 18
24,000 24
30,000 30
34,000 36
48,000 48
60,000 60
72,000 72
96,000 96
Wall mounted
ASUA4TLAV1
ASUA7TLAV1
ASUA9TLAV1
ASUA12TL AV1
ASUA14TL AV1
ASUB18TLAV1
ASUB24TLAV1
ASUB30TLAV1
ASUB36TLAV1
ASUA7TLAV
ASUA9TLAV
ASUA12TL AV
ASUA14TL AV
ASUB18TLAV
ASUB24TLAV
MODEL DESIGNATION
A U U A 1 2 T L A V
1 2 3 4 5 6 7 8 9 10
Type
AU: Cassette
AR: Duct
AB: Floor/Ceiling
or Ceiling
AS: Wall Mounted
Destination
U: FUJITSU
Model
A: Standard
(AU, AS)
B: Large
(AU, AS)
L: Slim
(AR)
M: Mid Static
(AR)
H: High Static
Pressure
(AR)
V: Vertical air
handler(AR)
Model code
(kBtu/h)
7 (7. 5)
9 (9.5)
12 (12.0)
14 (14.0)
18 (18.0)
24 (24.0)
30 (30.0)
36 (36.0)
48 (48.0)
60 (60.0)
72 (72.0)
96 (96.0)
Function
T: Heat
pump
Function
L: Inverter
Function
A: 1 Phase
Function
V: VRF
1
11
Version
1
- (01-05) -
GENERAL
INFORMATION
GENERAL
INFORMATION